Page History
...
Code Block | ||||
---|---|---|---|---|
| ||||
(ana-4.0.42) [dubrovin@psanagpu105:~/LCLS/con-py2]$ deploy_constants -h usage: deploy_constants -e <experiment> -d <detector> -r <run-number> -C <calib-type> [-D] [-L <logging-mode>] [...] REGULAR COMMAND EXAMPLE: deploy_constants -e xpptut15 -r 260 -d XcsEndstation.0:Epix100a.1 -C gain -D -c ./calib -D --runrange 10-20 Input parameters to select dataset: # DataSource argument: -e xpptut15 -r 260 # exp=xpptut15:run=260 -e xpptut15 -r 260 -s :smd # exp=xpptut15:run=260:smd -e xpptut15 -r 260 -s :dir=path/xtc::stream=0-79 # exp=xpptut15:run=260:dir=path/xtc::stream=0-79 -x /cds/data/drpsrcf/mfx/mfxlv4920/xtc/<file-name.xtc> # /cds/data/drpsrcf/mfx/mfxlv4920/xtc/<file-name.xtc> TEST COMMANDS: Ex.1 for epix100a : deploy_constants -e xpptut15 -r 260 -d XcsEndstation.0:Epix100a.1 -C gain -D -c ./calib Ex.2 for Cspad CXI : deploy_constants -e xpptut15 -r 380 -d CxiDs1.0:Cspad.0 -C gain -D -c ./calib Ex.3 for Cspad CXI : deploy_constants -e xpptut15 -r 380 -d CxiDs2.0:Cspad.0 -C gain -D -c ./calib Ex.4 for Cspad XPP : deploy_constants -e xpptut15 -r 320 -d XppGon.0:Cspad.0 -C gain -D -c ./calib Ex.5 for cspad2x2 : deploy_constants -e xpptut15 -r 460 -d MecTargetChamber.0:Cspad2x2.3 -C gain -D -c ./calib Ex.6 for pnCCD : deploy_constants -e xpptut15 -r 450 -d Camp.0:pnCCD.1 -C gain -D -c ./calib Help: deploy_constants -h Deployment of calibration parameters optional arguments: -h, --help show this help message and exit -e EXP, --exp EXP experiment name, default = None -d DET, --det DET detector name, default = None -r RUN, --run RUN run number of the existing dataset to get run time- stamp, detector full name etc., default = None -t TSTAMP, --tstamp TSTAMP non-default time stamp (YYYYmmddHHMMSS) to search for constants in repo. By default run time is used, default = None -s DSSUFFIX, --dssuffix DSSUFFIX dataset name suffix beyond exp=<expname>:run=<runnum><dssuffix>, for example ":smd:dir=<path>/xtc/", default = None -x DSNAME, --dsname DSNAME overrides exp=<expname>:run=<runnum><dssuffix> if specified, e.g. path to *.xtc file, default = None -o DIRREPO, --dirrepo DIRREPO non-default repository of calibration results, default = /reg/g/psdm/detector/calib/constants/ -c DIRCALIB, --dircalib DIRCALIB non-default deployment calib directory, different from standard one, default = None -C CTYPE, --ctype CTYPE calibration type [gain, common_mode, etc.], default = gain -l LOGLEV, --loglev LOGLEV logging mode, one of INFO, CRITICAL, WARN, WARNING, ERROR, DEBUG, NOTSET, default = INFO --dirmode DIRMODE mode for all mkdir, default = 511 --filemode FILEMODE mode for all saved files, default = 438 -D, --deploy deploy constants to the calib dir, default = False -R RUNRANGE, --runrange RUNRANGE validity run range for output calibration file, default = 0-end |
Repository
Repository structure is defined for flexibility Structure of repository is designed to account for detector dependent type/id/name and time dependent and default constants:
Code Block |
---|
Repository: repodir = /reg/g/psdm/detector/calib/constants/ Log files: <repodir>/logs/ - directory for log files <repodir>/logs/<YEAR>/<time-stamp>_log_deploy_constants_<uid>.txt ex: <repodir>/logs/2022/2022-06-09T121926_log_deploy_constants_dubrovin.txt Detector type directory: <repodir>/<dettype> - detector type directory for dettypes: cspad, cspad2x2, epix100a, pnccd <repodir>/<dettype>/.aliases.txt - dictionary between detector id/name and short alias Directory for default files: <repodir>/<dettype>/default/ <dettype>_default_<ctype>.txt ex: epix100a_default_gain.txt Specific detector directory: <repodir>/<dettype>/<detector-id-or-name>/ Calibration type subdirectory: <repodir>/<dettype>/<detector-id-or-name>/<calib-type>/ <dettype>_<alias>_<YYYYmmddHHMMSS>_<exp-name>_r<run-number>_<ctype>.txt ex: epix100a_0001_20100101000000_xpptut15_r0260_gain.txt |
...
- /reg/g/psdm/detector/calib/constants/epix100a/default/epix100a_default_common_mode.txt, epix100a_default_gain.txt, epix100a_default_geometry.txt
- /reg/g/psdm/detector/calib/constants/epix100a/3925999616-0996579585-0553648138-1232098304-1221641739-2650251521-3976200215/gain/epix100a_0001_20100101000000_xpptut15_r0260_gain.txt → reference to one of defaults.
If needed repository content of repository can be extended for other detectors and calibration types.
...
Default gains for epix100a are set in software as uniteequal to ones. Some of users requested constants as 0.060 keV/ADU. File epix100a_default_gain.txt contains gain factors 0.06 for all pixels. Command to install this constants is
deploy_constants -e <experiment> -d <detector> -r <run-number> -C gain -D
For example, test it for deployment in your Test command below deploys constants under the local calib directory:
deploy_constants -e xpptut15 -r 260 -d XcsEndstation.0:Epix100a.1 -C gain -D -c calib
Functionality
Fully flagged command Command with correct list of parameters (-e xpptut15 -r 260 -d XcsEndstation.0:Epix100a.1 -C gain) tries to access if available or create the repository directory tree. If specific file for the run or specified (-t TSTAMP, --tstamp TSTAMP) time stamp is available it will be deployed under standard or specified (-c DIRCALIB, --dircalib DIRCALIB) calib directory. If calibration file is not found - nothing is deployed and appropriate warning is generated in the log file. Created directory tree for new detector can be used to add new default or time-stamp-dependent calibration files.