- Check permanent and variable filtering (flippies) for cameras in laser room – Laser cameras and alignment references
- Check permanent and variable filtering (flippies) for cameras in tunnel – Laser cameras and alignment references
- Determine safe set of motor positions for everything in the PB – Motor positions
- Fix hole size for laser shutter enclosures
- Write up procedure/check list
- Measure change in collimation as function of pump delay (SAGA attenuation?)?
During ramp up
- Attenuate laser and gradually ramp up
- Check light levels on all cameras, look out for abnormalities that indicate damage
- Check vacuum levels as beam is dumped on compressor block
- Check vacuum levels as beam is dumped on laser beam dump in PB
- Check for damage, signs of ablation etc. around compressor block and laser beam dump in PB
- Check if scaling on laser diagnostics matches expected energy scaling (for on-shot energy measurement)
...