MANUAL OPTION:

Just do it.

Spreadsheet from Dan VanWinkle on how to keep 16 MV when we lose one RF
station. (May 2007).  All values are in kV.

Station 

...

Future

...

Voltage 

If 2 Cav Park

If 4 Cav Park

HR41

1200

...

0

1400

HR46

...

1100

1350

1400

HR81

2100

...

2150

2400

HR83

2200

2200

...

0

HR85

...

2200

2200

2400

HR21

...

1200

1350

1400

HR22

1200

...

1350

1400

HR23

1200

...

1350

1400

HR24

1200

...

1350

1400

HR25

...

1200

1350

1400

HR26

...

1200

1350

1400

Total

...

16000

16000

...

16

Total Voltage
4 Cav VCavity stations at  2400 kV  or 600 kV/Cav 2400 600
2 Cav VCavity stations at  1200 kV  or 600 kV/Cav 1200 600

EPICS CONFIG LOAD:

SCP config files for use in the parking of a given HER RF station exist.  The configuration region is called HER_GAPV (SCP path INDEX -> CONFIG -> MISC CONFIG -> EPICS CONFIG -> HER GAP VOLT) and the NORMAL directory has setups for parking each station. Configs for 2007 are still in the works These new configuration files save the following parameters for each RF station in HER:

...

  •  Check for no circulating beam in the machine.
  •  Get Gap Voltage total from EPICS.
  •  Calculate new comb filter coefficient and enter it into the inactive bank on the Comb-2 modules.
  • Activate  Activate the inactive bank.

Note 1: To back out of the changes made by this program; just make the new inactive bank active.  (For all Comb-2 modules)

Note 2: There is no need to save combComb-2 configuration files since the Matlab function can be run anytime one needs new comb filter coefficients.

...