4 mirrors and thin-film polarisers 

p-pol as input


Attenuates to 0.5*0.8*0.5*0.1 = 0.02 (2%)


Issues:

  • Appears to introduce astigmatism
  • Ghosts when changing polarisation


Image Added

2022 RP attenuator


4 mirrors and s-pol as input.

Mirrors are 35%R from MPO, AR coating on back and 2 degree wedge.

Attenuation should be down to 0.35^4 = 0.015 (1.5%) or 800 mJ * 0.35^4 = 12 mJ


Reflectivity was tested:


Wedge orientation:

...