Page History
...
- different modes for powercycling xpm's: (fru_deactivate commands, clia, nothing for xpm:3)
- solution for xpm:3 is to have IT install ethernet connection to shelf manager
- needed because xpm register bus would sometimes lockup
- hsd test-pattern mode
- solution is to restart the long-lived hsd ioc process, possibly more than once.
- TMO: hsd.cnf RIX: rix-hsd.cnf
Code Block | ||||||
---|---|---|---|---|---|---|
| ||||||
$ procmgr status rix-hsd.cnf
Host UniqueID Status PID PORT Command+Args
daq-rix-hsd-01 hsdioc_1a RUNNING 140606 28076 hsd134PVs -P DAQ:RIX:HSD:1_1A -d /dev/pcie_adc_1a
daq-rix-hsd-01 hsdioc_1b RUNNING 141684 28075 hsd134PVs -P DAQ:RIX:HSD:1_1B -d /dev/pcie_adc_1b
drp-neh-ctl002 hsdpvs_1a_a RUNNING 63077 28073 hsdpvs -P DAQ:RIX:HSD:1_1A:A
drp-neh-ctl002 hsdpvs_1a_b RUNNING 63118 28074 hsdpvs -P DAQ:RIX:HSD:1_1A:B
drp-neh-ctl002 hsdpvs_1b_a RUNNING 63069 28071 hsdpvs -P DAQ:RIX:HSD:1_1B:A
drp-neh-ctl002 hsdpvs_1b_b RUNNING 63070 28072 hsdpvs -P DAQ:RIX:HSD:1_1B:B |
- hsd configure phase2 failing
- xpm tx link resets necessary
- zombie hsd's creating deadtime
- difficulties switching between internal/external timing
- powercycle order for at least one rix andor usb/optical converters (intermittent)
- camlink converter box doesn't always work (power-cycle it last?)
- acr-side sxr xtcav doesn't come back
- lustre mount difficulties
- no ipmi on psmetric nodes (solution: these will be decommissioned)
Overview
Content Tools