Main screen → Profile Monitor → LI20 → PYDM All Cameras (big green button)
OLD (deprecated as of 2021/08/11):
Main screen → Profile Monitor → LI20 → Dump Cameras
- To change gain settings, go to Camera... in the Settings column.
- If camera is not responding or died (green light off), press the Reboot button at the far right of the panel
...
The camera triggers are the same as for the dump table in general.
Find them here:
How to find the motor controls on EPICS
For motors (XPS controllers)
Main screen → Experimenter
For horizontal motion:
UTS150
Main screen → Experimenter → MC02 (in FCKG20-27), Ch07
OUT/furthest distance to beam axis is at ~120 or so (away from motor).
This is 150 minus the early stop on the motor.
For vertical motion
UTS100
Main screen → Experimenter → MC03 (in FCKG20-26), Ch05
OUT/furthest distance to beam axis (lowest position) is at 100 (away from motor).