Page History
...
- Click "Stop" in the "Image Collection" section of the main IOC window
- Make sure the "Readout Mode" (middle of the IOC sub panel) in the "Collect" section is set to "Image" and NOT "FVB" (full vertical binning)
- caput RIX:DIR:CAM:01:AndorIsolatedCropMode Enable
- Set the roi to 90x90 on the main screen in the "Acquisition Settings" section (other settings may work at lower rates. need to ask Dan).
- NOTE: I don't understand why, but I appear to have to enter the "Y" region size before I enter the "X" region size.
- Set the "Cam Trig Event Code" to the appropriate value in the "Timestamps" section of the main IOC window
- Click "Start" in the "image Collection" section of the main IOC window
- Verify that "Capture Rate" in the "Image Collection" section of the main IOC panel is what you expect
...
Overview