  • Previous action items:
    • Cameron reported on studies he has conducted where he has dropped all SVT fits with times below 50ns, irrespective of whether a single or double pulse was fit to the waveform. This resulted in a loss of ~10% of tracks which had previously passed the analysis quality cuts. Work will continue to understand what pulse fits should be kept.
    • Currently we anticipate reconstructing the ~10% sample with the current set of Drivers and keeping the current set of collections. The SVT needs the raw data in order to determine the baseline calibrations. However, we still need to reduce the output size for final production reconstruction of the full 2019 data set.
    • Reconstructing 10% of the data under current settings would result in ~150TB of disk-resident lcio files. HPS only has a guarantee of ~85TB on /cache, so we would be flushing the files we currently have on /cache and files would not be disk-resident for long, but files would be written to tape before being deleted.
    • We discussed whether we need 10% of the data, or whether a smaller fraction would be sufficient. It was suggested that the SVT group come up with a set of specific files that are needed for the baseline calibration and proceed with that.
  • Jeremy gave an interactive demonstration of the online reconstruction and monitoring tools. The online reconstruction tools are documented at Online Reconstruction Tools.

...