Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

1) ApvClkAlign     (to set all the APVs to the same phase)
2) ApvReset101.  (reset and start to wait for a trigger signal)


Start local svt data taking

With the hybrids configured and synced. 

1) Go to HpsSvtDaqRoot tab→Browse and then set the name of the file ( it will set the output name with data and time automatically)
2) Cick on Open. You will see File Open → True when ready.
3) Set run Rate to something reasonable (10Hz should be OK)
4) Click on Run State and select "Running". When successfully running you'll see Run Count going up. 
5) When done with local data taking, first set Run State to "Stopped" and Close the file. 


Configuration files used to configure rogue.
The 2019 CODA (central DAQ software at jLab) configuration files for HPS DAQ are stored on jLab machines at

...