'amcc_dump_bsi --all shm-tst-lab2-atca02/2' (from psdev) will tell you if the slot 2 xpm (XPM:2) ethernet link is up.
Can check light levels going into the xpm by looking at EPICS variables like this:
Code Block |
---|
(ps-4.1.2) tmo-daq:scripts> pvget DAQ:NEH:XPM:0:SFPSTATUS
DAQ:NEH:XPM:0:SFPSTATUS 2021-01-13 14:36:15.450
LossOfSignal ModuleAbsent TxPower RxPower
0 0 6.5535 6.5535
1 0 0.5701 0.0001
0 0 0.5883 0.7572
0 0 0.5746 0.5679
0 0 0.8134 0.738
0 0 0.6844 0.88
0 0 0.5942 0.4925
0 0 0.5218 0.7779
1 0 0.608 0.0001
0 0 0.5419 0.3033
1 0 0.6652 0.0001
0 0 0.5177 0.8751
1 1 0 0
0 0 0.7723 0.201 |
Opal
NOTE: when powering on the opal/feb-box (front-end-board) the LED on the FEB box will stay red until the DAQ has configured it, when it will turn green. Also, only after the DAQ configuration is done will the "@ID?" and "@BS?" uart strings sent to the camera here work. This is probably also fixable by loading a rogue yaml config file included in the cameralink-gateway git repo:
...