Comment: Preparing for a RIX PV Scan

...

Code Block
languagetext
titlebluesky_rix.py demo
$ python bluesky_rix.py 

Transient Scan ID: 1     Time: 2020-12-10 18:24:53
Persistent Unique Scan ID: '2092a9ca-160c-4b52-8683-256f699e1e01'
New stream: 'primary'
+-----------+------------+------------+
|   seq_num |       time |     motor1 |
+-----------+------------+------------+
|         1 | 18:24:58.5 |    -10.000 |
|         2 | 18:24:59.6 |     -8.571 |
|         3 | 18:25:00.6 |     -7.143 |
|         4 | 18:25:01.6 |     -5.714 |
|         5 | 18:25:02.7 |     -4.286 |
|         6 | 18:25:03.7 |     -2.857 |
|         7 | 18:25:04.8 |     -1.429 |
|         8 | 18:25:05.8 |      0.000 |
|         9 | 18:25:06.8 |      1.429 |
|        10 | 18:25:07.9 |      2.857 |
|        11 | 18:25:08.9 |      4.286 |
|        12 | 18:25:10.0 |      5.714 |
|        13 | 18:25:11.0 |      7.143 |
|        14 | 18:25:12.0 |      8.571 |
|        15 | 18:25:13.1 |     10.000 |
+-----------+------------+------------+
generator scan ['2092a9ca'] (scan num: 1)

Preparing for a RIX PV Scan

As a general rule, one should always verify that the DAQ is running well in "normal" mode before attempting to run a scan.

Some specific tips:

  1. Make sure all the detectors to be used are configured properly.
  2. Make sure the timing system is configured properly.  As of this writing, RIX uses readout groups 2 and 5.
  3. When you're ready to record a scan, don't forget to enable recording before running bluesky_rix.py!  In the control GUI, the disk icon is green when recording.
  4. Use the "normal" DAQ interface to select the detectors of interest as "active" and assign their readout groups.
  5. Put the DAQ in ALLOCATED or CONNECTED state. Now, you are ready to run bluesky_rix.py.

The bluesky_rix.py script accepts several command line arguments. If you are relying on the default settings, make sure they are correct for your experiment now, not just way back in 2020 when the script was first written.





Code Block
languagetext
titlebluesky_rix.py help
bluesky_rix.py -h
usage: bluesky_rix.py [-h] [-B PVBASE] [-p {0,1,2,3,4,5,6,7}] [-x XPM]
                      [-C COLLECT_HOST] [-t TIMEOUT] [-c READOUT_COUNT]
                      [-g GROUP_MASK] [--config ALIAS] [-v]

optional arguments:
  -h, --help            show this help message and exit
  -B PVBASE             PV base (default DAQ:NEH)
  -p {0,1,2,3,4,5,6,7}  platform (default 2)
  -x XPM                master XPM (default 0)
  -C COLLECT_HOST       collection host (default drp-neh-ctl001)
  -t TIMEOUT            timeout msec (default 10000)
  -c READOUT_COUNT      # of events to aquire at each step (default 120)
  -g GROUP_MASK         bit mask of readout groups (default 36)
  --config ALIAS        configuration alias (default BEAM)
  -v                    be verbose