Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • measurement order of points per quad should be kept done in style of Chris Kenney's style , as shown on photo.
  • microscope origin location does not matter, but can be labeled somewhere for uniformity of metrology data.
  • metrology data is saved in xlsx (in spreadsheets xlsx or text ) formatformat.
  • units - signed micrometers, without decimal dot.
  • example of data:
Code Block
titleExample of optical metrology data in text format
collapsetrue
quad 0
point   X       Y       Z
1       0       0       0
2       403     39683   -147
3       37088   39308   -472
4       36680  -378     -326
5       322     40433   -141
6       366     80129   -302
7       37056   80079   -657
8       37007   40391   -452
9       42053   40578   -470
10      42046   80274   -669
11      78743   80269   -961
12      78733   40576   -725
13      42083   219     -297
14      42078   39472   -413
15      78774   39473   -711
16      78767   214     -640
quad 1
point   X       Y       Z
1       81539   -4620   -731
2       81352   32062   -814
3       121034  32267   -1079
4       121225  -4420   -1015
5       81390   37579   -882
6       81497   74238   -993
7       121177  74148   -1219
8       121073  37468   -1127
9       122083  37596   -1104
10      122171  74281   -1329
11      161853  74189   -1620
12      161768  37499   -1433
13      122081  -4398   -916
14      122183  32283   -988
15      161877  32161   -1333
16      161765  -4520   -1286


Quad 2
...
Quad 3
...

...

  • All labels on detector connectors and cables should show THE ONLY way WAY to connect camera in hatch.

Summary

  • Engrave detector name on camera body.
  • Add labels for unambiguous detector orientation:
    • vector of gravity,
    • x-y (and optional origin) for optical metrology,
    • all labels should be left-to-right readable in hatch (now for now 2M.0 they are upside-down).
  • Use the same detector orientation in optical metrology, Q0 is in upper left corner in microscope x-y. Origin does not matter.
  • Use the same order of measuring points per quad, as numerated on photo.
  • Connect camera connectors to properly labeled cables.

...