Page History
...
UNSOLVED (1MHz): with both the fake cam and hsd Matt saw that if he ran at 1MHz then disabled for a few seconds then reenabled that all the buffers were stuck in software and system would hang. Reproducible 1 out of 3 attempts. Learned that Pause/Resume does not see this problem - must just disable triggers. When this happens, the monitoring shows that the DRP does not process all of the L1s. It's like a batch gets stuck. After that, nothing gets processed (transition or more L1s).
UNSOLVED (1MHz): when we record 10 hsd's to disk disable times out for several segment levels. No errors in logfiles. Timeouts too short for 1MHz?
...