CXI has two in-vacuum 2.3M CSPAD pixel-array detectors.  Each detector is stationed downstream of one of CXI's three interaction points and can be read-out individually, together, or independently – allowing CXI the capability to operate two experiments simultaneously using a single X-Ray beam.  When running two experiments during the same shift, the upstream experiment uses the DS1 CSPAD in the primary DAQ from cxi-daq, while the downstream parasitic experiment will use the DS2 CSPAD in the secondary DAQ from cxi-monitor.

Image Removed

The   The names DS1 and DS2 refer to the vacuum chambers that contain the CSPAD detectors.  

Image Added

Detector Chamber Motors

  The chambers also contain a handful of motorized beamline components such as pulse pickers, beamstops, vacuum gauges, and alignment stages.  Taking a look at the EPICS PV descriptions of the detector chamber motors, we can get an idea of what else is inside them.  Obtaining the descriptions of the DS1 motors using caget,

...

we find the motors are for alignment stages, X-Ray focusing optics, a pulse picker, attenuator and more.  

Control Screens

EDM control GUIs for detector chamber devices can be pulled up using the CXI Home Screen and clicking the "DSA", "DSC", "DSD" icons for detector power, and "DS1", "DS2" motor status circles as they appear under detector stand locations on the beamline map (top left of images).  Note that the motor control screens for the detector chamber motors are password protected and beamline staff have sworn a sacred oath to never speak the password to anyone ever.  If an HXR staff member reveals the password to you, please report them to Sebastien Boutet so he may take punitive action.  

...

DS1 and DS2 have companion mobile equipment racks, named D50 and D51 respectively.  The racks are nearly identical twins and each contain power supplies and readout electronics for detectors, a Digi, a 4-channel stepper motor controller and an EPICS IOC server.  The mobile racks handle controls and feedback for detector power and diagnostics, some stepper motor control, and serve as an interface for detector data and timing input/output.  A rack profile listing of the mobile racks' devices is shown below.  

Mobile Rack Vertical Layout

1CSPAD ConcentratorHandles CSPAD data readout
2Detector PDUConsolidates power from MPOD with other analog control and timing signals to detector input
3MPODEPICS controllable High/Low voltage power supply for detectors
4EPICS IOC ServerIOC for motors, encoders and power supplies running from the mobile rack
5Digi Serial Port ServerSerial communication input/output terminal
6Dumb Motor ControllerFor in-vacuum LS-180 CSPAD Z-stage
7120V AC Power SupplyPower supply for mobile rack electronics
8Motor Power SupplyPower supply for dumb motors

Mobile Rack Hosts

Mobile RackIOC Server HostnameDigi Hostname
D50ioc-cxi-protura1digi-cxi-21
D51ioc-cxi-protura2digi-cxi-31

...