Page History
...
The common-mode methods still correlate, but the default method perhaps over-subtracts because of leakage into the zero-photon peak from neighbor-pixels of real photons.
Crystallography Case
Here are the common mode corrections applied to a crystal diffraction pattern with a strong water ring using algorithms 1 vs 5. Algorithm 5 seems to perform better in this case.
Common mode histogram using algorithm 1
Common mode histogram using algorithm 5
Summary for CSPAD
Common mode correction for CSPAD works with algorithm #1 and shows significant effect.
...
Overview