SwitchDescriptionNotes
-bActivates batch mode plotting so plots will not be shown when running job. 
-dSet the name of the detector model. 
-DAdd a variable definition that applies to the input steering file. 
-fText file containing list of input EVIO files. 
-LSet log level.

DEPRECATED.

Use logging config file or class instead.

-lPath of output LCIO file. 
-mSet the max event buffer size.Experts only.
-MUse memory mapping in EVIO reader instead of sequential access.Experts only.
-nMaximum number of events to process in the job. 
-RSet the run number to be used when initializing the conditions system. 
-tSpecify a conditions tag for filtering conditions records. 
-vPrint out EVIO converted to XML for every event.For verbose debugging of events.
-rInterpret steering file from -x as a classpath resource rather than a file. 
-xSteering fileCould be resource or file depending on if -r switch is used.

...