We have a new release of GlastRelease that includes all the new (filter) configuration information i.e. getting the Moot key, extracting the correct filter information (DGN prescales for example) and automatically configuring and running the correct filters in Gleam. This GR also has the real FSW filter bits in the Merit ntuple.

This GR has a known problem: The Gleam HIP fillter passes (actually, leaks) all events. It's possible that the Gleam MIP filter suffers from a smaller degree of the same problem.  

There are updates to the SVAC ntuple and the monitoring to adapt to this new GR.

...

We have processed real data and MC on the DEV server with this version of L1Proc.

We have in particular tested two important use cases:

1/ If a run has no Moot key, we still retrieve the LAtC key from the data and use it to retrieve the correct trigger configuration (se we can deduce the correct trigger engines).
2/ If a run has a Moot key we use it as intended.

Note that there are no changes in the HalfPipe because of this GR. The relevant tables (Run Id - Moot key association) are being filled independently of L1 (and has been for some while).  

...