- Place database QR sticker on HSIO board and follow instructions on Documentation page.
- Place database sticker on TTC board and follow same instructions.
- DTM already has database page.
- If there is an RTM that goes with this HSIO, create database page for it too.
Electrical tests:
- Download HSIO_C03-xx Power Up.xlsx
- Save (replace xx with board number).
- Download Map for probe locations.
- Run resistance check entering values in excel file.
- If values are okay proceed to voltage check, else put aside for re-work.
- Load FPGA with this HsioPowerOn_00000001.bit file.
- Power board with 12V and 0.5 Amp current limit, check that current limit not reached - should be between 0.2 and 0.3 amps.
- Check voltages and record in the excel file.
- Upload excel file to database page created above (scan QR code to find page).
- If okay proceed to functional test, else put aside for re-work.
...