Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Test Procedure

We have processed LPA and LCI runs in the DEV pipeline with this version of L1Proc.

We fully reprocessed a few hours of data from ...August 04: http://glast-ground.slac.stanford.edu/Pipeline-II/exp/Fermi/si.jsp?stream=18776132272862&dataSourceMode=DevImage Modified

We were not able to reprocess an LCI runs, because the calibration tables are populated only from Jul 31st, 2013.

Rollback procedure

We can easily switch back to the previous version of L1Proc before the FSSC switches over to the new photon database (we probably have a few hours to rollback, if needed). This would have to be coordinated with ASP.

...

L1Pipeline: L1Pipeline-04-04-00
- Do not create SVAC tuples
- Change procver to 202 for all exported file types
- New GR GlastRelease-17-35-24-lp54lp56
- New ST ScienceTools-09-32-05
- New DiffRsp, new ft2Utils, new fitsGen for P202
- Add ability to ignore some deliveries when merging LONE-190@JIRA
- Don't clean up chunks until we're really done LONE-193@JIRA
- Improve retry handling LONE-194@JIRA

ScienceTools: ScienceTools-09-32-05

GlastRelease: GlastRelease-17-35-24-lp56
- There are several differences between GlastRelease-17-35-24-lp56 and GlastRelease-17-35-24-lp54ScienceTools: ScienceTools-09-32-05lp40 (currently used in L1Proc). Most packages were updated to keep up with the Science Tools release.
- We ran Systests comparing GlastRelease-17-35-24-lp56 and GlastRelease-17-35-24-lp40 and there are differences in Overlay and BackGndMixDC2. We think we understand these differences in terms of the updated flux & celestialSources in the updated version of astro (plus a bugfix introduced in Overlay starting from GlastRelease-17-35-24-lp43). Carmelo blessed the results of systests in an email.

evtClassDefs: evtClassDefs-00-19-05
- add for PASS_VER = P7REP

...