  1. Login to tracker@ppa-pc88427 and open a terminal
  2. Setup environment: $cd /u1/software/daq && source setup_env.csh
  3. Kill processes related to the tracker and CODA (if any is running): $ cd /u1/software/scripts && StopLocalCodaAll
  4. On desktop #1:
    1. $ cd /u1/software/daq && RestartTrackerDaq
    2. $StartExpertGui
    3. Configure the SVT using the Expert GUI:
      1. Hard Reset => Load Settings ("config/coda_defaults.xml")=> Load Settings ("config/coda_groupC.xml")=>Soft Reset
      2. You should see good sync (#apv's depends on what is connected)
  5. On desktop #2:
    1. open a terminal and setup environment: $cd /u1/software/daq && source setup_env.csh && cd /u1/software/scripts/
    2. $ ./StartLocalCodaAll
    3. You should see three terminals: Run Control Platform, coda master and trackerRoc and one coda master GUI
    4. Select "coda" in the coda master GUI => opens a new coda master gui where you need to enable buttons
    5. Click Event Builder in the coda master gui => should open a smaller gui
    6. Click Run Control in the coda master gui => should open the large run control gui
    7. Click: connect, Configure, Download, Prestart (check progress in trackerRoc (apv sync status) and in run control gui for each step).
    8. Run with Go.
  6. To look at the data being taken go to desktop #1:
    1. $cd /u1/software/daq && source setup_env.csh && StartOnlineGui
  7. The data is written to the file /u1/software/coda/test.dat

SVT Layout in Lab

SVT Half

Cooling loop (from chiller side)

Side in lab (from chiller side)

Flange

Top

"away"

"away"

short cable (outside cold box)

Bottom

"same"

"same"

long cable (outside cold box)

...