Properties of the calorimeter which is realized as a dual readout optical calorimeter and muon system:
| electromagnetic section | hadronic section | muon system | ||
material | BGO (PbF2) | BGO (PbF2) | Iron | ||
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="2bc6152f-2ed3-4d9f-95be-2f5ab6d5ea86"><ac:plain-text-body><![CDATA[ | density [ g/cm3 ] | 7.13 (7.77) | 7.13 (7.77) | 7.85 | ]]></ac:plain-text-body></ac:structured-macro> |
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="e39b6be9-a765-49b7-8e7d-0275a4d34693"><ac:plain-text-body><![CDATA[ | Cell size [ cm ] | 1x1x2 | 2x2x5 | 10x10x10 | ]]></ac:plain-text-body></ac:structured-macro> |
Layers | 10 | 30 | 22 | ||
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="922217e5-9b6c-48ac-9cb8-6e93fa1e6484"><ac:plain-text-body><![CDATA[ | Detector Depth [cm] | 20 | 150 | 220 | ]]></ac:plain-text-body></ac:structured-macro> |
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="a7a6d376-fbf9-4ecd-8833-74c2b96960c6"><ac:plain-text-body><![CDATA[ | Radiation Length [cm] Radiation Length (cm) | 1.1 (0.93) | 1.1 (0.93) | 1.76 | ]]></ac:plain-text-body></ac:structured-macro> |
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="7ec0a131-6c9d-477c-8a7f-70db380b7d5a"><ac:plain-text-body><![CDATA[ | IA length [cm] | 22.7 (22.4) | 22.7 (22.4) | 16.8 | ]]></ac:plain-text-body></ac:structured-macro> |
Total Nr of IA length (em+had) | 7.5 (7.6) |