Properties of the calorimeter which is realized as a dual readout optical calorimeter and muon system:
| electromagnetic section | hadronic section | muon system | ||
material | BGO (PbF2) | BGO (PbF2) | Iron | ||
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="7ad7d604-da09-4b58-b82a-ab0620b7426e"><ac:plain-text-body><![CDATA[ | density [ g/cm3 ] | 7.13 (7.77) | 7.13 (7.77) | 7.85 | ]]></ac:plain-text-body></ac:structured-macro> |
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="773e1f4c-b133-4f21-b1b0-d1ecf8afbb85"><ac:plain-text-body><![CDATA[ | Cell size [ cm ] | 1x1x2 | 2x2x5 | 10x10x10 | ]]></ac:plain-text-body></ac:structured-macro> |
Layers | 10 | 30 | 22 | ||
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="925e1104-27eb-43fc-9e7f-b6422fe2a4d3"><ac:plain-text-body><![CDATA[ | Detector Depth [cm] | 20 | 150 | 220 | ]]></ac:plain-text-body></ac:structured-macro> |
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="e261d2fc-24c0-4da1-8493-7f9e45ea7620"><ac:plain-text-body><![CDATA[ | Radiation Length [cm] Radiation Length (cm) | 1.1 (0.93) | 1.1 (0.93) | 1.76 | ]]></ac:plain-text-body></ac:structured-macro> |
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="0db149f9-bfc6-48e6-9e04-ab0e321c09c6"><ac:plain-text-body><![CDATA[ | IA length [cm] | 22.7 (22.4) | 22.7 (22.4) | 16.8 | ]]></ac:plain-text-body></ac:structured-macro> |
Total Nr of IA length (em+had) | 7.5 (7.6) |