Long writeup of study

Mapped Field, Results:

Note: The Z Pos is the position of the beam relative to the target. The X pos, is relative to the "absolute coordinates", which means relative to the beam when all magnets are off.

The center of the magnet in this simulation is at 88.485 mm. So to get the position of the beam relative to the center of the magnet, take (X_pos - 88.485 mm).



Electron

Photon

Name

Z Pos

X Pos

X Pos

A1 - 110

-314.2 mm

55.71 mm

-

A2 - 111

-100 mm

64.14 mm

-

B1 -  10 Target (+2 mm)

  2 mm

67.37 mm

-

A3 - 112 Silicon 1

+100 mm

69.64 mm

70.36 mm

A4 - 113 Silicon 2

+200 mm

71.48 mm

73.42 mm

A5 - 114 Silicon 3

+300 mm

72.63 mm

76.47 mm

A6 - 115 Silicon 4

+500 mm

73.22 mm

82.58 mm

A7 - 116 Silicon 5

+700 mm

71.10 mm

88.68 mm

A8 - 117 Magnet Exit

+900.1 mm

66.29 mm

94.79 mm

B3 -  12 Ecal Entry

1319 mm

50.64 mm

107.6 mm

B4 -  13 Ecal Middle

1549 mm

41.54 mm

114.6  mm

...