Total time to power on all towers: 856 seconds
Average tower power on time: 856 seconds
Total time to power on all free boards: 663 seconds
Average free board power on time: 663 seconds
:
:
siuFeedVoltage: SIU 0 feed voltage 0.78V is within [-1.0, 1.0]
siuTemp: SIU 0 temperature 32.28C is within [23.0, 50.0]
:
siuFeedVoltage: SIU 0 feed voltage 28.08V is within [27.0, 29.0]
siuCurrentDelta: SIU 0 feed current delta 0.72A is within [-1.0, 1.0]
siuVoltage: SIU 0 3.3/5V voltage 2.34V is within [0.0, 6.0]
siuMemCheck: SIU 0 Memory Check passed.
siuCommCheck: SIU 0 Comm Check passed.
siuBootTlm: SIU boot telemetry received.
siuTemp: SIU 0 temperature 32.28C is within [23.0, 50.0]
:
siuVoltage: SIU 0 3.3/5V voltage 2.42V is within [0.0, 6.0]
siuMemCheck: SIU 0 Memory Check passed.
siuCommCheck: SIU 0 Comm Check passed.
siuBootTlm: SIU boot telemetry received.
siuTemp: SIU 0 temperature 33.09C is within [23.0, 50.0]
:
latHskTlm: LAT housekeeping telemetry received.
siuTemp: SIU 0 temperature 32.64C is within [23.0, 50.0]
:
siuCurrentDelta: Checking if dwell telemetry is in range [-1.0, 1.0] for payload VSC_RBPU_SIU_C, values ['-0.01', '-0.01', '0.02', '-0.03', '-0.00'] (starting with index:0, margin:0)
siuCurrentDelta: Dwell telemetry for payload VSC_RBPU_SIU_C are within [-1.0, 1.0]
siuVoltage: Checking if dwell telemetry is in range [0.0, 6.0] for payload L_DAQ_P_SIU_V, values ['2.34', '2.39', '2.40', '2.34', '2.34'] (starting with index:0, margin:0)
siuVoltage: Dwell telemetry for payload L_DAQ_P_SIU_V are within [0.0, 6.0]
siuTemp: Checking if dwell telemetry is in range [23.0, 50.0] for payload L_DAQ_P_SIU_T, values ['33.09', '33.36', '33.00', '32.64', '33.00'] (starting with index:0, margin:0)
siuTemp: Dwell telemetry for payload L_DAQ_P_SIU_T are within [23.0, 50.0]
siuFeedVoltage: Checking if dwell telemetry is in range [27.0, 29.0] for payload VSC_RBPU_SIU_V, values ['28.13', '28.03', '27.93', '28.08', '27.64'] (starting with index:0, margin:0)
siuFeedVoltage: Dwell telemetry for payload VSC_RBPU_SIU_V are within [27.0, 29.0]
siuCpuJTemp: Checking if dwell telemetry is in range [1, 999] for payload LHKSIUCPUJTEMP, values ['39.00', '39.00', '39.00', '39.00', '39.00', '39.00', '39.00', '39.00', '39.00', '39.00', '39.00'] (starting with index:0, margin:0)
siuCpuJTemp: Dwell telemetry for payload LHKSIUCPUJTEMP are within [1, 999]
siuCpuLdMin: Checking if dwell telemetry is in range [1, 999] for payload LHKSIUCPULDMIN, values ['1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00'] (starting with index:0, margin:0)
siuCpuLdMin: Dwell telemetry for payload LHKSIUCPULDMIN are within [1, 999]
siuCpuAvLdm: Checking if dwell telemetry is in range [1, 999] for payload LHKSIUCPUAVLDM, values ['1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00'] (starting with index:0, margin:0)
siuCpuAvLdm: Dwell telemetry for payload LHKSIUCPUAVLDM are within [1, 999]
siuCpuAvLds: Checking if dwell telemetry is in range [1, 999] for payload LHKSIUCPUAVLDS, values ['1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00'] (starting with index:0, margin:0)
siuCpuAvLds: Dwell telemetry for payload LHKSIUCPUAVLDS are within [1, 999]
siuCpuLdMax: Checking if dwell telemetry is in range [1, 999] for payload LHKSIUCPULDMAX, values ['1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00'] (starting with index:0, margin:0)
siuCpuLdMax: Dwell telemetry for payload LHKSIUCPULDMAX are within [1, 999]
:
:
readDaqFeedCurrent: Read the DAQ feed current as 0.15A
daqFeedVoltage: DAQ feed voltage -0.39V is within [-1.0, 1.0]
:
daqFeedVoltage: DAQ feed voltage 27.93V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta -0.10A is within [-1.0, 1.0]
pduTemp: PDU temperature 24.15C is within [23.0, 50.0]
pduVoltage: PDU 0 3.3Vvoltage 0.03V is within [0.0, 6.0]
:
daqFeedVoltage: DAQ feed voltage 28.03V is within [27.0, 29.0]
gasu33V: Checking if dwell telemetry is in range [3.0, 3.6000000000000001] for payload L_DAQ_P_EBM33V, values ['1.05', '3.35', '3.30', '3.32', '3.35'] (starting with index:2, margin:0)
gasu33V: Dwell telemetry for payload L_DAQ_P_EBM33V are within [3.0, 3.6000000000000001]
daqFeedVoltage: Checking if dwell telemetry is in range [27.0, 29.0] for payload VSC_RBPU_DAQ_V, values ['27.93', '27.73', '28.17', '28.08', '28.08'] (starting with index:2, margin:0)
daqFeedVoltage: Dwell telemetry for payload VSC_RBPU_DAQ_V are within [27.0, 29.0]
gasuTemp: Checking if dwell telemetry is in range [23.0, 30.0] for payload L_DAQ_P_GASU_T, values ['24.29', '24.29', '24.29', '24.29', '24.29'] (starting with index:2, margin:0)
gasuTemp: Dwell telemetry for payload L_DAQ_P_GASU_T are within [23.0, 30.0]
pduVoltage: Checking if dwell telemetry is in range [0.0, 6.0] for payload L_DAQ_P_PDU_V, values ['0.00', '3.35', '3.36', '3.35', '3.35'] (starting with index:2, margin:0)
pduVoltage: Dwell telemetry for payload L_DAQ_P_PDU_V are within [0.0, 6.0]
pduTemp: Checking if dwell telemetry is in range [23.0, 50.0] for payload L_DAQ_P_PDU_T, values ['24.15', '23.67', '24.01', '23.40', '24.01'] (starting with index:2, margin:0)
pduTemp: Dwell telemetry for payload L_DAQ_P_PDU_T are within [23.0, 50.0]
gasu25V: Checking if dwell telemetry is in range [2.0, 2.6000000000000001] for payload L_DAQ_P_EBM25V, values ['0.00', '2.50', '2.44', '2.45', '2.42'] (starting with index:2, margin:0)
gasu25V: Dwell telemetry for payload L_DAQ_P_EBM25V are within [2.0, 2.6000000000000001]
gasu25V: Checking if dwell telemetry is in range [2.0, 2.6000000000000001] for payload L_DAQ_P_GEM25V, values ['0.04', '2.48', '2.46', '2.44', '2.50'] (starting with index:2, margin:0)
gasu25V: Dwell telemetry for payload L_DAQ_P_GEM25V are within [2.0, 2.6000000000000001]
gasu33V: Checking if dwell telemetry is in range [3.0, 3.6000000000000001] for payload L_DAQ_P_GEM33V, values ['1.02', '3.32', '3.32', '3.32', '3.28'] (starting with index:2, margin:0)
gasu33V: Dwell telemetry for payload L_DAQ_P_GEM33V are within [3.0, 3.6000000000000001]
daqCurrentDelta: Checking if dwell telemetry is in range [-1.0, 1.5] for payload VSC_RBPU_DAQ_C, values ['-0.29', '0.68', '0.49', '0.39', '0.29'] (starting with index:2, margin:0)
daqCurrentDelta: Dwell telemetry for payload VSC_RBPU_DAQ_C are within [-1.0, 1.5]
:
daqFeedVoltage: DAQ feed voltage 28.13V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta 0.29A is within [-1.0, 1.5]
pduTemp: PDU temperature 24.01C is within [23.0, 50.0]
pduVoltage: PDU 0 3.3Vvoltage 3.35V is within [0.0, 6.0]
gasuVoltages: AEM/EBM 3.3V voltage 3.35V is within [3.0, 3.6000000000000001]
gasuVoltages: AEM/EBM 2.5V voltage 2.46V is within [2.0, 2.6000000000000001]
gasuVoltages: CRU/GEM 3.3V voltage 3.28V is within [3.0, 3.6000000000000001]
gasuVoltages: CRU/GEM 2.5V voltage 2.46V is within [2.0, 2.6000000000000001]
:
daqFeedVoltage: DAQ feed voltage 27.69V is within [27.0, 29.0]
epuTemp: PDU 0 EPU 0 temperature measured as 22.11C and within the required range of [-30.0, 45.0]
epuPwrMgt: Checking if dwell telemetry is in range [1, 1] for payload LHKP0EPU0PM, values ['0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00'] (starting with index:8, margin:5)
epuPwrMgt: Dwell telemetry for payload LHKP0EPU0PM are within [1, 1]
epuTemp: Checking if dwell telemetry is in range [-30.0, 45.0] for payload LHKP0EPU0T, values ['22.11', '22.11', '22.11', '22.11', '22.11', '22.11', '22.11', '22.11', '22.11', '22.11', '22.11', '22.11', '22.11', '22.11', '22.08', '22.08', '22.08', '22.08', '22.08', '22.08'] (starting with index:8, margin:5)
epuTemp: Dwell telemetry for payload LHKP0EPU0T are within [-30.0, 45.0]
epuCnvt: Checking if dwell telemetry is in range [0, 0] for payload LHKP0EPU0CNVT, values ['0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00'] (starting with index:8, margin:5)
epuCnvt: Dwell telemetry for payload LHKP0EPU0CNVT are within [0, 0]
:
daqFeedVoltage: DAQ feed voltage 27.73V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta 0.44A is within [-1.0, 1.0]
epuVoltage: PDU 0 EPU 0 3.3V voltage measured as 2.25V and within the required range of [2.0, 3.5]
epuBootTlm: EPU boot telemetry received.
epuTemp: PDU 0 EPU 0 temperature measured as 22.26C and within the required range of [-30.0, 45.0]
:
epuVoltage: PDU 0 EPU 0 3.3V voltage measured as 2.25V and within the required range of [2.0, 3.5]
epuTemp: PDU 0 EPU 0 temperature measured as 23.10C and within the required range of [-30.0, 45.0]
:
epuHskTlm: EPU 0 CPU junction temperature measured as 47 and within the required range of [1, 999]
epuTemp: PDU 0 EPU 0 temperature measured as 23.35C and within the required range of [-30.0, 45.0]
:
daqFeedVoltage: DAQ feed voltage 27.73V is within [27.0, 29.0]
epuTemp: PDU 0 EPU 1 temperature measured as 21.89C and within the required range of [-30.0, 45.0]
epuPwrMgt: Checking if dwell telemetry is in range [1, 1] for payload LHKP0EPU1PM, values ['0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00', '1.00'] (starting with index:8, margin:5)
epuPwrMgt: Dwell telemetry for payload LHKP0EPU1PM are within [1, 1]
epuCnvt: Checking if dwell telemetry is in range [0, 0] for payload LHKP0EPU1CNVT, values ['0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00'] (starting with index:8, margin:5)
epuCnvt: Dwell telemetry for payload LHKP0EPU1CNVT are within [0, 0]
epuTemp: Checking if dwell telemetry is in range [-30.0, 45.0] for payload LHKP0EPU1T, values ['21.89', '21.89', '21.89', '21.89', '21.89', '21.89', '21.86', '21.86', '21.86', '21.86', '21.86', '21.86', '21.86', '21.89', '21.89', '21.89', '21.89', '21.89', '21.89', '21.89'] (starting with index:8, margin:5)
epuTemp: Dwell telemetry for payload LHKP0EPU1T are within [-30.0, 45.0]
:
daqFeedVoltage: DAQ feed voltage 27.73V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta 0.73A is within [-1.0, 1.0]
epuVoltage: PDU 0 EPU 1 3.3V voltage measured as 2.26V and within the required range of [2.0, 3.5]
epuBootTlm: EPU boot telemetry received.
epuTemp: PDU 0 EPU 1 temperature measured as 21.92C and within the required range of [-30.0, 45.0]
:
epuVoltage: PDU 0 EPU 1 3.3V voltage measured as 2.26V and within the required range of [2.0, 3.5]
epuTemp: PDU 0 EPU 1 temperature measured as 22.14C and within the required range of [-30.0, 45.0]
:
epuHskTlm: EPU 1 CPU junction temperature measured as 40 and within the required range of [1, 999]
epuTemp: PDU 0 EPU 1 temperature measured as 22.38C and within the required range of [-30.0, 45.0]
:
daqFeedVoltage: DAQ feed voltage 28.13V is within [27.0, 29.0]
daqFeedVoltage: PDU 0 TEM 12 power supply temperature measured as 24.52C and within the required range of [-40.0, 60.0]
temDaqTemp: PDU 0 TEM 12 DAQ board temperature measured as 24.41C and within the required range of [-40.0, 60.0]
temDaqTemp: PDU 0 TEM 12 power supply temperature measured as 24.48C and within the required range of [-40.0, 60.0]
temPsTemp: PDU 0 TEM 12 power supply temperature measured as 24.52C and within the required range of [-40.0, 60.0]
temVoltage: Checking if dwell telemetry is in range [3.0, 3.5] for payload LHKTCTEM33V, values ['0.21', '0.21', '0.21', '0.21', '0.21', '0.21', '0.21', '0.21', '0.21', '0.21', '0.21', '0.21', '0.21', '3.41', '3.41', '3.41', '3.41', '3.41', '3.41', '3.41'] (starting with index:8, margin:7)
temVoltage: Dwell telemetry for payload LHKTCTEM33V are within [3.0, 3.5]
temPsVoltage: Checking if dwell telemetry is in range [27.0, 29.0] for payload LHKTCTEM28V0, values ['33.05', '33.05', '33.05', '33.05', '33.05', '33.05', '33.05', '33.05', '33.05', '33.05', '33.05', '33.05', '33.05', '28.13', '28.13', '28.13', '28.13', '28.13', '28.13', '28.13'] (starting with index:8, margin:7)
temPsVoltage: Dwell telemetry for payload LHKTCTEM28V0 are within [27.0, 29.0]
temPsVoltage: Checking if dwell telemetry is in range [27.0, 29.0] for payload LHKTCTEM28V1, values ['29.57', '29.57', '29.57', '29.57', '29.57', '29.57', '29.57', '29.57', '29.57', '29.57', '29.57', '29.57', '29.57', '28.09', '28.09', '28.09', '28.09', '28.09', '28.09', '28.09'] (starting with index:8, margin:7)
temPsVoltage: Dwell telemetry for payload LHKTCTEM28V1 are within [27.0, 29.0]
:
daqFeedVoltage: DAQ feed voltage 27.88V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta 0.24A is within [-1.0, 1.0]
temPsCurrent: Warning: Conversion constant for LDETCTEM28I was not in the database, using the data from the configuration file
temPsCurrent: TEM 12 power supply current measured as 0.23A and within the required range of [-1.0, 5.0]
temVoltage: TEM 12 3.3V voltage measured as 3.40V and within the required range of [3.0, 3.5]
temDaqTemp: PDU 0 TEM 12 DAQ board temperature measured as 24.41C and within the required range of [-40.0, 60.0]
temPsTemp: PDU 0 TEM 12 power supply temperature measured as 24.52C and within the required range of [-40.0, 60.0]
:
temPsTemp: PDU 0 TEM 12 power supply temperature measured as 24.58C and within the required range of [-30.0, 45.0]
calAfeeTemp: TEM 12 CAL AFEE 0 temperature 1 measured as 33.07C and within the required range of [23.0, 40.0]
calAfeeTemp: TEM 12 CAL AFEE 1 temperature 1 measured as 32.65C and within the required range of [23.0, 40.0]
calAfeeTemp: TEM 12 CAL AFEE 2 temperature 1 measured as 32.61C and within the required range of [23.0, 40.0]
calAfeeTemp: TEM 12 CAL AFEE 3 temperature 1 measured as 32.12C and within the required range of [23.0, 40.0]
cal33VA: Checking if dwell telemetry is in range [3.0, 3.5] for payload LHKTCCAL33VA, values ['0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '3.36', '3.36', '3.36', '3.36', '3.36', '3.36', '3.36', '3.36', '3.36', '3.36', '3.36', '3.36', '3.36', '3.36'] (starting with index:8, margin:5)
cal33VA: Dwell telemetry for payload LHKTCCAL33VA are within [3.0, 3.5]
cal33VD: Checking if dwell telemetry is in range [3.0, 3.5] for payload LHKTCCAL33VD, values ['0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '3.44', '3.44', '3.44', '3.44', '3.44', '3.44', '3.44', '3.44', '3.44', '3.44', '3.44', '3.44', '3.44', '3.44'] (starting with index:8, margin:5)
cal33VD: Dwell telemetry for payload LHKTCCAL33VD are within [3.0, 3.5]
temPsVoltage: Checking if dwell telemetry is in range [27.0, 29.0] for payload LHKTCTEM28V0, values ['28.13', '28.13', '28.13', '28.13', '28.13', '28.13', '27.94', '27.94', '27.94', '27.94', '27.94', '27.94', '27.94', '27.94', '27.94', '27.94', '27.94', '27.94', '27.94', '27.94'] (starting with index:8, margin:5)
temPsVoltage: Dwell telemetry for payload LHKTCTEM28V0 are within [27.0, 29.0]
temPsVoltage: Checking if dwell telemetry is in range [27.0, 29.0] for payload LHKTCTEM28V1, values ['28.09', '28.09', '28.09', '28.09', '28.09', '28.09', '27.96', '27.96', '27.96', '27.96', '27.96', '27.96', '27.96', '27.95', '27.95', '27.95', '27.95', '27.95', '27.95', '27.95'] (starting with index:8, margin:5)
temPsVoltage: Dwell telemetry for payload LHKTCTEM28V1 are within [27.0, 29.0]
calBiasVoltage: Checking if dwell telemetry is in range [0.0, 80.0] for payload LHKTCCALBSV1, values ['0.06', '0.06', '0.06', '0.06', '0.06', '0.06', '25.84', '25.84', '25.84', '25.84', '25.84', '25.84', '25.84', '25.77', '25.77', '25.77', '25.77', '25.77', '25.77', '25.77'] (starting with index:8, margin:5)
calBiasVoltage: Dwell telemetry for payload LHKTCCALBSV1 are within [0.0, 80.0]
calBiasVoltage: Checking if dwell telemetry is in range [0.0, 80.0] for payload LHKTCCALBSV0, values ['0.12', '0.12', '0.12', '0.12', '0.12', '0.12', '0.18', '0.18', '0.18', '0.18', '0.18', '0.18', '0.18', '0.18', '0.18', '0.18', '0.18', '0.18', '0.18', '0.18'] (starting with index:8, margin:5)
calBiasVoltage: Dwell telemetry for payload LHKTCCALBSV0 are within [0.0, 80.0]
:
daqFeedVoltage: DAQ feed voltage 27.73V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta -0.15A is within [-1.0, 1.0]
temPsCurrent: Warning: Conversion constant for LDETCTEM28I was not in the database, using the data from the configuration file
temPsCurrent: TEM 12 power supply current measured as 0.50A and within the required range of [-1.0, 5.0]
cal33V: TEM 12 CAL 3.3V digital measured as 3.44V and within the required range of [3.0, 3.5]
cal33V: TEM 12 CAL 3.3V analog measured as 3.36V and within the required range of [3.0, 3.5]
calBias: TEM 12 CAL bias V0 measured as 0.18V and within the required range of [0.0, 80.0]
calBias: TEM 12 CAL bias V1 measured as 25.84V and within the required range of [0.0, 80.0]
calBias: TEM 12 CAL bias current measured as 0.01A and within the required range of [-1.0, 6.0]
calAfeeTemp: TEM 12 CAL AFEE 0 temperature 1 measured as 33.07C and within the required range of [23.0, 40.0]
calAfeeTemp: TEM 12 CAL AFEE 1 temperature 1 measured as 32.65C and within the required range of [23.0, 40.0]
calAfeeTemp: TEM 12 CAL AFEE 2 temperature 1 measured as 32.65C and within the required range of [23.0, 40.0]
calAfeeTemp: TEM 12 CAL AFEE 3 temperature 1 measured as 32.20C and within the required range of [23.0, 40.0]
:
temPsTemp: PDU 0 TEM 12 power supply temperature measured as 24.71C and within the required range of [-30.0, 45.0]
tkrTemp: TEM 12 TKR cable 0 temperature 0 measured as 33.07C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 0 temperature 1 measured as -108.07C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 1 temperature 0 measured as 33.50C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 1 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 2 temperature 0 measured as 32.45C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 2 temperature 1 measured as -108.07C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 3 temperature 0 measured as 34.27C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 3 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 4 temperature 0 measured as 32.57C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 4 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 5 temperature 0 measured as 33.75C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 5 temperature 1 measured as -108.07C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 6 temperature 0 measured as 32.08C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 6 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 7 temperature 0 measured as 33.71C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 7 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkr15VA: Checking if dwell telemetry is in range [0.0, 2.0] for payload LHKTCTKR15VAA, values ['0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '1.51', '1.51', '1.51', '1.51', '1.51', '1.51', '1.51', '1.51', '1.51', '1.51', '1.51', '1.51'] (starting with index:8, margin:5)
tkr15VA: Dwell telemetry for payload LHKTCTKR15VAA are within [0.0, 2.0]
temPsVoltage: Checking if dwell telemetry is in range [27.0, 29.0] for payload LHKTCTEM28V0, values ['27.94', '27.94', '27.94', '27.94', '27.94', '27.94', '27.94', '27.94', '27.94', '27.59', '27.59', '27.59', '27.59', '27.59', '27.59', '27.58', '27.58', '27.58', '27.58', '27.58'] (starting with index:8, margin:5)
temPsVoltage: Dwell telemetry for payload LHKTCTEM28V0 are within [27.0, 29.0]
temPsVoltage: Checking if dwell telemetry is in range [27.0, 29.0] for payload LHKTCTEM28V1, values ['27.96', '27.96', '27.95', '27.95', '27.95', '27.95', '27.95', '27.95', '27.95', '27.72', '27.72', '27.72', '27.72', '27.72', '27.72', '27.70', '27.70', '27.70', '27.70', '27.70'] (starting with index:8, margin:5)
temPsVoltage: Dwell telemetry for payload LHKTCTEM28V1 are within [27.0, 29.0]
tkr25VD: Checking if dwell telemetry is in range [0.0, 3.0] for payload LHKTCTKR25VD, values ['0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '2.58', '2.58', '2.58', '2.58', '2.58', '2.58', '2.58', '2.58', '2.58', '2.58', '2.58', '2.58'] (starting with index:8, margin:5)
tkr25VD: Dwell telemetry for payload LHKTCTKR25VD are within [0.0, 3.0]
tkrBiasVoltage: Checking if dwell telemetry is in range [0.0, 100.0] for payload LHKTCTKRBV0, values ['0.06', '0.06', '0.06', '0.06', '0.06', '0.06', '0.06', '0.06', '0.31', '0.31', '0.31', '0.31', '0.31', '0.31', '0.31', '0.31', '0.31', '0.31', '0.31', '0.31'] (starting with index:8, margin:5)
tkrBiasVoltage: Dwell telemetry for payload LHKTCTKRBV0 are within [0.0, 100.0]
tkrBiasVoltage: Checking if dwell telemetry is in range [0.0, 100.0] for payload LHKTCTKRBV1, values ['0.12', '0.12', '0.06', '0.06', '0.06', '0.06', '0.06', '0.06', '0.06', '25.65', '25.65', '25.65', '25.65', '25.65', '25.65', '25.59', '25.59', '25.59', '25.59', '25.59'] (starting with index:8, margin:5)
tkrBiasVoltage: Dwell telemetry for payload LHKTCTKRBV1 are within [0.0, 100.0]
tkr25VA: Checking if dwell telemetry is in range [0.0, 3.0] for payload LHKTCTKR25VAB, values ['0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '2.63', '2.63', '2.63', '2.63', '2.63', '2.63', '2.63', '2.63', '2.63', '2.63', '2.63', '2.63'] (starting with index:8, margin:5)
tkr25VA: Dwell telemetry for payload LHKTCTKR25VAB are within [0.0, 3.0]
:
daqFeedVoltage: DAQ feed voltage 27.88V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta 0.78A is within [-1.0, 1.0]
temPsCurrent: Warning: Conversion constant for LDETCTEM28I was not in the database, using the data from the configuration file
temPsCurrent: TEM 12 power supply current measured as 1.06A and within the required range of [-1.0, 5.0]
tkrVoltage: TEM 12 TKR 1.5V analog measured as 1.51V and within the required range of [0.0, 2.0]
tkrVoltage: TEM 12 TKR 2.5V digital measured as 2.58V and within the required range of [0.0, 3.0]
tkrVoltage: TEM 12 TKR 2.5V analog measured as 2.63V and within the required range of [0.0, 3.0]
tkrBias: TEM 12 TKR bias V0 measured as 0.31V and within the required range of [0.0, 100.0]
tkrBias: TEM 12 TKR bias V1 measured as 25.65V and within the required range of [0.0, 100.0]
tkrBias: Warning: Conversion constant for LDETCTKRBIASI was not in the database, using the data from the configuration file
tkrBias: TEM 12 TKR bias current measured as 0.01A and within the required range of [-1.0, 10.0]
tkrTemp: TEM 12 TKR cable 0 temperature 0 measured as 33.20C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 0 temperature 1 measured as -108.07C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 1 temperature 0 measured as 33.54C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 1 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 2 temperature 0 measured as 32.53C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 2 temperature 1 measured as -108.07C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 3 temperature 0 measured as 34.36C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 3 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 4 temperature 0 measured as 32.69C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 4 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 5 temperature 0 measured as 33.80C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 5 temperature 1 measured as -108.07C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 6 temperature 0 measured as 32.36C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 6 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 7 temperature 0 measured as 33.92C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 12 TKR cable 7 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
:
gasuVoltages: AEM/EBM 3.3V voltage 3.38V is within [3.0, 3.6000000000000001]
gasuVoltages: AEM/EBM 2.5V voltage 2.44V is within [2.0, 2.6000000000000001]
freeBoardTemp: Warning: Received not ready status for AEM free board 0 temp.
freeBoardTemp: Warning: PowerOnAcdFreeBoard : Prerequisite - Operator forced test freeBoardTemp to pass
freeBoardTemp: Checking if dwell telemetry is in range [-120.0, 30.0] for payload LHKAEMFR0T, values ['-13.56', '-13.56', '-13.56', '-13.56', '-98.71', '-98.71', '-98.71', '-98.71', '-98.71', '-98.71', '-98.71', '-114.72', '-114.72', '-114.72', '-114.72', '-114.72', '-114.72', '-114.72', '-114.72', '-114.72'] (starting with index:20, margin:0)
freeBoardTemp: Dwell telemetry for payload LHKAEMFR0T are within [-120.0, 30.0]
freeBoardVoltage: Checking if dwell telemetry is in range [0.0, 29.0] for payload LHKAEMFR0VD, values ['0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00', '0.00'] (starting with index:20, margin:0)
freeBoardVoltage: Dwell telemetry for payload LHKAEMFR0VD are within [0.0, 29.0]
:
gasuVoltages: AEM/EBM 3.3V voltage 3.28V is within [3.0, 3.6000000000000001]
gasuVoltages: AEM/EBM 2.5V voltage 2.48V is within [2.0, 2.6000000000000001]
freeBoardVoltage: AEM free board 0 voltage measured as 0.00V and within the required range of [0.0, 29.0]
freeBoardCurrent: AEM free board 3.3 current sum measured as 0.00A and within the required range of [-1.0, 10.0]
freeBoardTemp: AEM free board 0 temperature measured as -114.72C and within the required range of [-120.0, 30.0]
:
gasuVoltages: AEM/EBM 3.3V voltage 3.30V is within [3.0, 3.6000000000000001]
gasuVoltages: AEM/EBM 2.5V voltage 2.45V is within [2.0, 2.6000000000000001]
pmtRailTemp: ACD PMT rail temperature 0 measured as -124.77C and within the required range of [-130.0, 30.0]
pmtRailTemp: ACD PMT rail temperature 1 measured as -124.77C and within the required range of [-130.0, 30.0]
:
gasuVoltages: AEM/EBM 3.3V voltage 3.35V is within [3.0, 3.6000000000000001]
gasuVoltages: AEM/EBM 2.5V voltage 2.40V is within [2.0, 2.6000000000000001]
hvbsVoltage: AEM free board 0 HV1 voltage measured as -16.39V and within the required range of [-100, 950]
hvbsVoltage: AEM free board 0 HV1 voltage measured as -15.71V and within the required range of [-100, 950]
psCurrent: AEM free board 0 28V current sum measured as 0.00A and within the required range of [-1.0, 10.0]
pmtRailTemp: ACD PMT rail temperature 0 measured as -124.77C and within the required range of [-130.0, 30.0]
pmtRailTemp: ACD PMT rail temperature 1 measured as -124.77C and within the required range of [-130.0, 30.0]
:
:
badAPID: Bad APID test passed. The result was ('CTS_APIDNOQ', '"APID %d (0x%04x) does not map to an ITC queue"')
invalidPayload: Invalid payload test passed. The result was ('LHK_PRMERR', '"Invalid command parameter: %s %x"')
incompleteCmd: Incomplete command test passed. CVT timeout occurred and EPKTPARM message was observed.
:
:
ambientPower: LAT input power measured as 88.75W and within the required range of [0, 750]
averagePower: LAT average input power measured as 89.71W and within the required range of [0, 650]
peakPower: LAT peak input power measured as 94.75W and within the required range of [0, 750]