LAT01x - LAT Power Off Sequence Test [101200233]

 

 

 

 

 

 

 

LatPowerOff
LAT01x - LAT Power Off Sequence Test

Mon Jan 30 11:17:41 2006

 

 

 

 

 

 

 

Test Summary

tbLatPowerOff.cfg

1.3

L00-01-00

101200233

online-v2r4p0_101200233_rcReport_rcReport.xml

Start Up Step Prerequisite Verification
Check if the SIU is Powered On PASSED PASSED
Check if the DAQ Feed is On PASSED PASSED
Check if the PDU and GASU are Powered On PASSED PASSED
Check if EPU 0 is Powered On PASSED PASSED
Check if EPU 1 is Powered On PASSED PASSED
Check if TEM 12 is Powered On PASSED PASSED
Check if TEM 12 CAL is Powered On PASSED PASSED
Check if TEM 12 TKR is Powered On PASSED PASSED
Check if ACD Free Board 0 is Powered On PASSED PASSED
Check if ACD Free Board 0 HVBS is Turned On PASSED PASSED
Reduce ACD HVBS for Free Board 0 to Minimum PASSED PASSED
Power Off ACD Free Board 0 PASSED PASSED
Reduce TEM 12 TKR Bias Voltage to Minimum PASSED PASSED
Power Off TEM 12 TKR PASSED PASSED
Reduce TEM 12 CAL Bias Voltage to Minimum PASSED PASSED
Power Off TEM 12 CAL PASSED PASSED
Power Off TEM 12 PASSED PASSED
Power Off EPU 1 PASSED PASSED
Power Off EPU 0 PASSED PASSED
Power Off GASU and PDU PASSED PASSED

PASSED

Check if the SIU is Powered On

siuFeedVoltage: SIU 0 feed voltage 28.27V is within [27.0, 29.0]

siuFeedCurrent: SIU 0 feed current 0.70A is within [-1.0, 20.0]

siuVoltage: SIU 0 3.3/5V voltage 2.38V is within [0.0, 6.0]

siuTemp: SIU 0 temperature 34.47C is within [23.0, 50.0]

Check if the DAQ Feed is On

daqFeedVoltage: DAQ feed voltage 27.78V is within [27.0, 29.0]

daqFeedCurrent: DAQ feed current 2.69A is within [-1.0, 20.0]

Check if the PDU and GASU are Powered On

gasuVoltages: AEM/EBM 3.3V voltage 3.34V is within [3.0, 3.6000000000000001]

gasuVoltages: AEM/EBM 2.5V voltage 2.44V is within [2.0, 2.6000000000000001]

gasuVoltages: CRU/GEM 3.3V voltage 3.35V is within [3.0, 3.6000000000000001]

gasuVoltages: CRU/GEM 2.5V voltage 2.46V is within [2.0, 2.6000000000000001]

gasuTemp: GASU temperature 26.43C is within [23.0, 30.0]

pduVoltage: PDU 0 3.3Vvoltage 3.36V is within [0.0, 6.0]

pduTemp: PDU temperature 25.77C is within [23.0, 50.0]

Check if EPU 0 is Powered On

epuTemp: PDU 0 EPU 0 temperature measured as 28.09C and within the required range of [-30.0, 45.0]

epuVoltage: PDU 0 EPU 0 3.3V voltage measured as 2.25V and within the required range of [2.0, 3.5]

epuPwrMgt: PDU 0 EPU 0 power management switch measured as 1 and within the required range of [1, 1]

epuHskTlm: EPU 0 CPU junction temperature measured as 43 and within the required range of [1, 999]

Check if EPU 1 is Powered On

epuTemp: PDU 0 EPU 1 temperature measured as 27.76C and within the required range of [-30.0, 45.0]

epuVoltage: PDU 0 EPU 1 3.3V voltage measured as 2.26V and within the required range of [2.0, 3.5]

epuPwrMgt: PDU 0 EPU 1 power management switch measured as 1 and within the required range of [1, 1]

epuHskTlm: EPU 1 CPU junction temperature measured as 43 and within the required range of [1, 999]

Check if TEM 12 is Powered On

temPsTemp: PDU 0 TEM 12 power supply temperature measured as 26.97C and within the required range of [-40.0, 60.0]

temDaqTemp: PDU 0 TEM 12 DAQ board temperature measured as 29.39C and within the required range of [-40.0, 60.0]

temVoltage: TEM 12 3.3V voltage measured as 3.40V and within the required range of [3.0, 3.5]

temPsVoltage: TEM 12 power supply voltage 0 measured as 27.58V and within the required range of [27.0, 29.0]

temPsVoltage: TEM 12 power supply voltage 1 measured as 27.70V and within the required range of [27.0, 29.0]

temPsCurrent: Warning: Conversion constant for LDETCTEM28I was not in the database, using the data from the configuration file

temPsCurrent: TEM 12 power supply current measured as 1.02A and within the required range of [-1.0, 5.0]

Check if TEM 12 CAL is Powered On

calAfeeTemp: TEM 12 CAL AFEE 0 temperature 1 measured as 33.32C and within the required range of [23.0, 40.0]

calAfeeTemp: TEM 12 CAL AFEE 1 temperature 1 measured as 33.24C and within the required range of [23.0, 40.0]

calAfeeTemp: TEM 12 CAL AFEE 2 temperature 1 measured as 33.58C and within the required range of [23.0, 40.0]

calAfeeTemp: TEM 12 CAL AFEE 3 temperature 1 measured as 33.07C and within the required range of [23.0, 40.0]

cal33V: TEM 12 CAL 3.3V digital measured as 3.43V and within the required range of [3.0, 3.5]

cal33V: TEM 12 CAL 3.3V analog measured as 3.35V and within the required range of [3.0, 3.5]

calBias: TEM 12 CAL bias V0 measured as 0.18V and within the required range of [0.0, 80.0]

calBias: TEM 12 CAL bias V1 measured as 25.71V and within the required range of [0.0, 80.0]

calBias: TEM 12 CAL bias current measured as 0.01A and within the required range of [-1.0, 6.0]

Check if TEM 12 TKR is Powered On

tkrVoltage: TEM 12 TKR 1.5V analog measured as 1.51V and within the required range of [0.0, 2.0]

tkrVoltage: TEM 12 TKR 2.5V digital measured as 2.58V and within the required range of [0.0, 3.0]

tkrVoltage: TEM 12 TKR 2.5V analog measured as 2.62V and within the required range of [0.0, 3.0]

tkrBias: TEM 12 TKR bias V0 measured as 0.31V and within the required range of [0.0, 100.0]

tkrBias: TEM 12 TKR bias V1 measured as 25.65V and within the required range of [0.0, 100.0]

tkrBias: Warning: Conversion constant for LDETCTKRBIASI was not in the database, using the data from the configuration file

tkrBias: TEM 12 TKR bias current measured as 0.01A and within the required range of [-1.0, 10.0]

tkrTemp: TEM 12 TKR cable 0 temperature 0 measured as 34.58C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 12 TKR cable 0 temperature 1 measured as -108.07C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 12 TKR cable 1 temperature 0 measured as 34.80C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 12 TKR cable 1 temperature 1 measured as -108.07C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 12 TKR cable 2 temperature 0 measured as 34.63C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 12 TKR cable 2 temperature 1 measured as -108.07C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 12 TKR cable 3 temperature 0 measured as 36.36C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 12 TKR cable 3 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 12 TKR cable 4 temperature 0 measured as 35.30C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 12 TKR cable 4 temperature 1 measured as -108.07C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 12 TKR cable 5 temperature 0 measured as 35.71C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 12 TKR cable 5 temperature 1 measured as -108.07C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 12 TKR cable 6 temperature 0 measured as 34.80C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 12 TKR cable 6 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 12 TKR cable 7 temperature 0 measured as 35.57C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 12 TKR cable 7 temperature 1 measured as -108.07C and within the required range of [-123.0, 40.0]

Check if ACD Free Board 0 is Powered On

gasuVoltages: AEM/EBM 3.3V voltage 3.32V is within [3.0, 3.6000000000000001]

gasuVoltages: AEM/EBM 2.5V voltage 2.46V is within [2.0, 2.6000000000000001]

freeBoardVoltage: AEM free board 0 voltage measured as 0.00V and within the required range of [0.0, 29.0]

freeBoardCurrent: AEM free board 3.3 current sum measured as 0.00A and within the required range of [-1.0, 10.0]

freeBoardTemp: AEM free board 0 temperature measured as -114.72C and within the required range of [-120.0, 30.0]

Check if ACD Free Board 0 HVBS is Turned On

hvbsVoltage: AEM free board 0 HV1 voltage measured as 29.17V and within the required range of [-100, 950]

hvbsVoltage: AEM free board 0 HV1 voltage measured as 29.17V and within the required range of [-100, 950]

psCurrent: AEM free board 28V current sum measured as 0.00A and within the required range of [-1.0, 10.0]

pmtRailTemp: ACD PMT rail temperature 0 measured as -124.77C and within the required range of [-130.0, 30.0]

pmtRailTemp: ACD PMT rail temperature 1 measured as -124.77C and within the required range of [-130.0, 30.0]

Reduce ACD HVBS for Free Board 0 to Minimum

hvbsVoltage: AEM free board 0 HV1 voltage measured as 30.53V and within the required range of [-60.0, 60.0]

Power Off ACD Free Board 0

gasuVoltages: AEM/EBM 3.3V voltage 3.35V is within [3.0, 3.6000000000000001]

gasuVoltages: AEM/EBM 2.5V voltage 2.48V is within [2.0, 2.6000000000000001]

freeBoardVoltage: AEM free board 0 voltage measured as 0.00V and within the required range of [0.0, 29.0]

Reduce TEM 12 TKR Bias Voltage to Minimum

tkrBias: TEM 12 TKR bias V0 measured as 0.31V and within the required range of [0.0, 100.0]

tkrBias: TEM 12 TKR bias V1 measured as 25.65V and within the required range of [0.0, 100.0]

tkrBias: Warning: Conversion constant for LDETCTKRBIASI was not in the database, using the data from the configuration file

tkrBias: TEM 12 TKR bias current measured as 0.01A and within the required range of [-1.0, 10.0]

Power Off TEM 12 TKR

tkrVoltage: TEM 12 TKR 1.5V analog measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

tkrVoltage: TEM 12 TKR 2.5V digital measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

tkrVoltage: TEM 12 TKR 2.5V analog measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

Reduce TEM 12 CAL Bias Voltage to Minimum

calBias: TEM 12 CAL bias V0 measured as 0.18V and within the required range of [0.0, 80.0]

calBias: TEM 12 CAL bias V1 measured as 25.84V and within the required range of [0.0, 80.0]

calBias: TEM 12 CAL bias current measured as 0.01A and within the required range of [-1.0, 10.0]

Power Off TEM 12 CAL

cal33V: TEM 12 CAL 3.3V digital measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

cal33V: TEM 12 CAL 3.3V analog measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

Power Off TEM 12

temVoltage: TEM 12 3.3V voltage measured as 1.14V and within the required range of [0.0, 2.0]

Power Off EPU 1

epuVoltage: PDU 0 EPU 1 3.3V voltage measured as 0.01V and within the required range of [0.0, 0.5]

Power Off EPU 0

epuVoltage: PDU 0 EPU 0 3.3V voltage measured as 0.01V and within the required range of [0.0, 0.5]

Power Off GASU and PDU