LAT01x - LAT Power Off Sequence Test [101200100]

 

 

 

 

 

 

 

LatPowerOff
LAT01x - LAT Power Off Sequence Test

Thu Jan 12 13:50:40 2006

 

 

 

 

 

 

 

Test Summary

tbLatPowerOff.cfg

1.1

101200100

online-v2r4p0_101200100_rcReport_rcReport.xml

Start Up Step Prerequisite Verification
Reduce ACD HVBS for Free Board 0 to Minimum PASSED PASSED
Power Off ACD Free Board 0 PASSED PASSED
Reduce TEM 12 TKR Bias Voltage to Minimum PASSED PASSED
Power Off TEM 12 TKR PASSED PASSED
Reduce TEM 12 CAL Bias Voltage to Minimum PASSED PASSED
Power Off TEM 12 CAL PASSED PASSED
Power Off TEM 12 PASSED PASSED
Power Off EPU 1 PASSED PASSED
Power Off EPU 0 PASSED PASSED
Power Off GASU and PDU PASSED PASSED

PASSED

Reduce ACD HVBS for Free Board 0 to Minimum

hvbsVoltage: AEM free board 0 HV1 voltage measured as 45.83V and within the required range of [-60.0, 60.0]

Power Off ACD Free Board 0

gasuVoltages: AEM/EBM 3.3V voltage 3.35V is within [3.0, 3.6000000000000001]

gasuVoltages: AEM/EBM 2.5V voltage 2.42V is within [2.0, 2.6000000000000001]

freeBoardVoltage: AEM free board 0 voltage measured as 0.00V and within the required range of [0.0, 29.0]

Reduce TEM 12 TKR Bias Voltage to Minimum

tkrBiasVoltage: TEM 12 TKR bias V0 measured as 0.31V and within the required range of [0.0, 100.0]

tkrBiasVoltage: TEM 12 TKR bias V1 measured as 25.53V and within the required range of [0.0, 100.0]

Power Off TEM 12 TKR

tkrVoltage: TEM 12 TKR 1.5V analog measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

tkrVoltage: TEM 12 TKR 2.5V digital measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

tkrVoltage: TEM 12 TKR 2.5V analog measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

Reduce TEM 12 CAL Bias Voltage to Minimum

calBiasVoltage: TEM 12 CAL bias V0 measured as 0.18V and within the required range of [0.0, 80.0]

calBiasVoltage: TEM 12 CAL bias V1 measured as 25.84V and within the required range of [0.0, 80.0]

Power Off TEM 12 CAL

cal33V: TEM 12 CAL 3.3V digital measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

cal33V: TEM 12 CAL 3.3V analog measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

Power Off TEM 12

temVoltage: TEM 12 3.3V voltage measured as 1.14V and within the required range of [0.0, 2.0]

Power Off EPU 1

epuVoltage: PDU 0 EPU 1 3.3V voltage measured as 0.00V and within the required range of [0.0, 0.5]

Power Off EPU 0

epuVoltage: PDU 0 EPU 0 3.3V voltage measured as 0.01V and within the required range of [0.0, 0.5]

Power Off GASU and PDU