MD study: characterize staggered L1 chirp -------------------------------------------------------------------------------- observation: beam tails that can be clipped by BC11 collimator suggest something is longitudinally wrong in L1 (or possibly before) -> want to investigate chirp setup in L1 to see how beam quality is affected new chirp setting: --> phi = arcsin[(E1/E2 + 1)*sin(psi)] where: E1, E2 are 11-1,2 ENLDs, psi = old 11-1,2 phase, phi = new 11-2 phase compare (1) current L1 chirp setup and (2) staggered L1 chirp setup: * procedure setup: - stable beam to S20 - 11-1,2 phases verified by scan - should have nominal BC11 BLEN setting on both chirp settings - change chirp -> send beam to TD11 -> let feedbacks converge -> send beam to S20 * measurements: - L2 wire profiles - L2, L3 emittance - IPWS1 wire size - DTOTR2 + SYAG image - XTCAV BLEN - PLIC signal - difference orbit between distributed/staggered chirp if time permits: repeat & compare msmts with BC11 collimator IN