LAT13x: LAT-SC Load Shed/Reset Interface Test [556000884]

 

 

 

 

 

 

 

LatScLoadShedInterface
LAT13x: LAT-SC Load Shed/Reset Interface Test

Fri Dec 1 11:17:11 2006

 

 

 

 

 

 

 

Hardware Configuration

1

AA

AA

Primary

Primary

Primary

Primary

Primary

Primary

Primary

0

1

1

Primary

Primary

Test Summary

ObsLoadShed.cfg

1.1

L00-51-03

556000884

556000884_rcReport.xml

Start Up Step Prerequisite Verification
Send Load Shed from SC PASSED PASSED

PASSED

Send Load Shed from SC

shed: LAT emitted Load Shed Alert Diagnostic at 1165000640.6

shed: Waiting 15.000000 seconds before verifying load shed results

Wait for Load Shed: LIM started disabling instrument power in response to a Load-Shed command

Wait for Load Shed: LIM sent the LTC-Stop command to the LTC task

Wait for Load Shed: LIM finished disabling instrument power in response to a Load-Shed command

Wait for Load Shed: LIM is about to reboot the SIU

Wait for Load Shed: All Expected actions recorded ['LIM started disabling instrument power in response to a Load-Shed command', 'LIM sent the LTC-Stop command to the LTC task', 'LIM finished disabling instrument power in response to a Load-Shed command', 'LIM is about to reboot the SIU']

siuPrimaryBoot: SIU Boot Type value is 'Commanded Start' which is one of the allowed values ['Commanded Start', 'Exception Start']

siuPrimaryBoot: SIU in primary boot with expected boot type ['Commanded Start', 'Exception Start']

siuCommCheck: SIU 1 Comm Check passed.

siuMemCheck: Warning: SIU 1 Memory Check did not pass.

siuMemCheck: Warning: loadShed : Verification - Operator forced test siuMemCheck to pass

siuMemCheck: Waiting 5 seconds for SC Feeds to be disabled

Unregulated Bus A Voltage: Warning: SE_PDUA_ESB_V measured as 20302.00 which is not within the required range of [24.0, 35.0]

Unregulated Bus A Voltage: Warning: loadShed : Verification - Operator forced test Unregulated Bus A Voltage to pass

Unregulated Bus B Voltage: Warning: SE_PDUB_ESB_V measured as 30582.00 which is not within the required range of [24.0, 35.0]

Unregulated Bus B Voltage: Warning: loadShed : Verification - Operator forced test Unregulated Bus B Voltage to pass

Siu Feed A Inhibit: Warning: SE_PAL3_SIU_INH telemetry point not present

Siu Feed A Inhibit: Warning: loadShed : Verification - Operator forced test Siu Feed A Inhibit to pass

Siu Feed B Inhibit: Warning: SE_PBL3_SIU_INH telemetry point not present

Siu Feed B Inhibit: Warning: loadShed : Verification - Operator forced test Siu Feed B Inhibit to pass

VCHP Feed A Switch: Warning: SE_PAL3_VCHP_SW telemetry point not present

VCHP Feed A Switch: Warning: loadShed : Verification - Operator forced test VCHP Feed A Switch to pass

VCHP Feed B Switch: Warning: SE_PBL3_VCHP_SW telemetry point not present

VCHP Feed B Switch: Warning: loadShed : Verification - Operator forced test VCHP Feed B Switch to pass

VCHP Feed A Voltage: Warning: L_DAQ_P_RVF_V measured as -93.87 which is not within the required range of [-1.0, 1.0]

VCHP Feed A Voltage: Warning: loadShed : Verification - Operator forced test VCHP Feed A Voltage to pass

VCHP Feed B Voltage: Warning: L_DAQ_R_RVF_V measured as -91.36 which is not within the required range of [-1.0, 1.0]

VCHP Feed B Voltage: Warning: loadShed : Verification - Operator forced test VCHP Feed B Voltage to pass