LAT Turbo Power On Sequence [556000650]

 

 

 

 

 

 

 

LatPowerOffHvbsTurbo
LAT Turbo Power On Sequence

Wed May 24 14:49:28 2006

 

 

 

 

 

 

 

Hardware Configuration

1

AA

AA

Primary

Primary

Primary

0

1

1

Primary

Test Summary

tbLatPowerOffTurbo.cfg

1.1

L00-26-00

556000650

556000650_rcReport.xml

Start Up Step Prerequisite Verification
Power Off ACD HV PASSED PASSED
Power Off TKR HV PASSED PASSED
Power Off CAL HV PASSED PASSED

PASSED

Power Off ACD HV

Power Off ACD HV Command: Disabling HV for free boards [0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11]...

Power Off ACD HV Command: Verified HV State Change

hvBiasVoltage: FREE0 HV1 Bias Voltage measured as 45.15 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE1 HV1 Bias Voltage measured as 38.15 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE2 HV1 Bias Voltage measured as 36.12 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE3 HV1 Bias Voltage measured as 38.97 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE4 HV1 Bias Voltage measured as 32.85 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE5 HV1 Bias Voltage measured as 53.19 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE6 HV1 Bias Voltage measured as 40.92 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE7 HV1 Bias Voltage measured as 30.47 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE8 HV1 Bias Voltage measured as 35.15 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE9 HV1 Bias Voltage measured as 52.96 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE10 HV1 Bias Voltage measured as -30.81 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE11 HV1 Bias Voltage measured as 19.10 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE0 HV2 Bias Voltage measured as 50.59 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE1 HV2 Bias Voltage measured as 40.95 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE2 HV2 Bias Voltage measured as 0.42 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE3 HV2 Bias Voltage measured as 51.55 and within the required range of [-60.0, 60.0]

hvBiasVoltage: Warning: Overriding limits [-60.000, 60.000] with new limits [-60.000, 160.000]

hvBiasVoltage: FREE4 HV2 Bias Voltage measured as 123.85 and within the required range of [-60.0, 160.0]

hvBiasVoltage: FREE5 HV2 Bias Voltage measured as 32.19 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE6 HV2 Bias Voltage measured as 32.76 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE7 HV2 Bias Voltage measured as 48.15 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE8 HV2 Bias Voltage measured as 4.21 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE9 HV2 Bias Voltage measured as 40.04 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE10 HV2 Bias Voltage measured as -36.25 and within the required range of [-60.0, 60.0]

hvBiasVoltage: FREE11 HV2 Bias Voltage measured as 2.78 and within the required range of [-60.0, 60.0]

Power Off TKR HV

Power of Tkr HV Command: Disabling HV for Trackers [0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15]...

Power of Tkr HV Command: Verified TKR bias voltage change

hvBiasVoltage: TKR0 HV0 Bias Voltage measured as 0.31 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR0 HV1 Bias Voltage measured as 25.22 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR1 HV0 Bias Voltage measured as 0.25 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR1 HV1 Bias Voltage measured as 25.10 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR2 HV0 Bias Voltage measured as 0.18 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR2 HV1 Bias Voltage measured as 24.91 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR3 HV0 Bias Voltage measured as 0.31 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR3 HV1 Bias Voltage measured as 24.97 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR4 HV0 Bias Voltage measured as 0.25 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR4 HV1 Bias Voltage measured as 25.03 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR5 HV0 Bias Voltage measured as 0.25 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR5 HV1 Bias Voltage measured as 25.10 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR6 HV0 Bias Voltage measured as 0.49 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR6 HV1 Bias Voltage measured as 24.97 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR7 HV0 Bias Voltage measured as 0.18 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR7 HV1 Bias Voltage measured as 24.97 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR8 HV0 Bias Voltage measured as 0.18 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR8 HV1 Bias Voltage measured as 24.97 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR9 HV0 Bias Voltage measured as 0.25 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKR9 HV1 Bias Voltage measured as 25.10 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKRA HV0 Bias Voltage measured as 0.37 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKRA HV1 Bias Voltage measured as 25.22 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKRB HV0 Bias Voltage measured as 0.25 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKRB HV1 Bias Voltage measured as 25.03 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKRC HV0 Bias Voltage measured as 0.31 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKRC HV1 Bias Voltage measured as 25.16 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKRD HV0 Bias Voltage measured as 0.18 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKRD HV1 Bias Voltage measured as 25.03 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKRE HV0 Bias Voltage measured as 0.25 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKRE HV1 Bias Voltage measured as 25.16 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKRF HV0 Bias Voltage measured as 0.37 and within the required range of [-0.0, 110.0]

hvBiasVoltage: TKRF HV1 Bias Voltage measured as 24.91 and within the required range of [-0.0, 110.0]

Power Off CAL HV

Power of CAL HV Command: Disabling HV for Calorimeters [0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15]...

Power of CAL HV Command: Verified CAL bias voltage change

hvBiasVoltage: CAL0 HV0 Bias Voltage measured as 0.31 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL0 HV1 Bias Voltage measured as 24.79 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL1 HV0 Bias Voltage measured as 0.18 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL1 HV1 Bias Voltage measured as 24.97 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL2 HV0 Bias Voltage measured as 0.12 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL2 HV1 Bias Voltage measured as 24.91 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL3 HV0 Bias Voltage measured as 0.18 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL3 HV1 Bias Voltage measured as 24.85 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL4 HV0 Bias Voltage measured as 0.18 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL4 HV1 Bias Voltage measured as 24.91 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL5 HV0 Bias Voltage measured as 0.25 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL5 HV1 Bias Voltage measured as 24.73 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL6 HV0 Bias Voltage measured as 0.18 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL6 HV1 Bias Voltage measured as 24.85 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL7 HV0 Bias Voltage measured as 0.43 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL7 HV1 Bias Voltage measured as 24.85 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL8 HV0 Bias Voltage measured as 0.25 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL8 HV1 Bias Voltage measured as 24.97 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL9 HV0 Bias Voltage measured as 0.25 and within the required range of [0.0, 80.0]

hvBiasVoltage: CAL9 HV1 Bias Voltage measured as 24.85 and within the required range of [0.0, 80.0]

hvBiasVoltage: CALA HV0 Bias Voltage measured as 0.25 and within the required range of [0.0, 80.0]

hvBiasVoltage: CALA HV1 Bias Voltage measured as 25.03 and within the required range of [0.0, 80.0]

hvBiasVoltage: CALB HV0 Bias Voltage measured as 0.31 and within the required range of [0.0, 80.0]

hvBiasVoltage: CALB HV1 Bias Voltage measured as 24.79 and within the required range of [0.0, 80.0]

hvBiasVoltage: CALC HV0 Bias Voltage measured as 0.18 and within the required range of [0.0, 80.0]

hvBiasVoltage: CALC HV1 Bias Voltage measured as 25.03 and within the required range of [0.0, 80.0]

hvBiasVoltage: CALD HV0 Bias Voltage measured as 0.18 and within the required range of [0.0, 80.0]

hvBiasVoltage: CALD HV1 Bias Voltage measured as 24.91 and within the required range of [0.0, 80.0]

hvBiasVoltage: CALE HV0 Bias Voltage measured as 0.49 and within the required range of [0.0, 80.0]

hvBiasVoltage: CALE HV1 Bias Voltage measured as 24.97 and within the required range of [0.0, 80.0]

hvBiasVoltage: CALF HV0 Bias Voltage measured as 0.18 and within the required range of [0.0, 80.0]

hvBiasVoltage: CALF HV1 Bias Voltage measured as 24.79 and within the required range of [0.0, 80.0]