Power Off ACD HV Command: Disabling HV for free boards [0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11]...
Power Off ACD HV Command: Verified HV State Change
:
hvBiasVoltage: FREE0 HV1 Bias Voltage measured as 45.15 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE1 HV1 Bias Voltage measured as 38.15 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE2 HV1 Bias Voltage measured as 36.12 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE3 HV1 Bias Voltage measured as 38.97 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE4 HV1 Bias Voltage measured as 32.85 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE5 HV1 Bias Voltage measured as 53.19 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE6 HV1 Bias Voltage measured as 40.92 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE7 HV1 Bias Voltage measured as 30.47 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE8 HV1 Bias Voltage measured as 35.15 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE9 HV1 Bias Voltage measured as 52.96 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE10 HV1 Bias Voltage measured as -30.81 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE11 HV1 Bias Voltage measured as 19.10 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE0 HV2 Bias Voltage measured as 50.59 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE1 HV2 Bias Voltage measured as 40.95 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE2 HV2 Bias Voltage measured as 0.42 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE3 HV2 Bias Voltage measured as 51.55 and within the required range of [-60.0, 60.0]
hvBiasVoltage: Warning: Overriding limits [-60.000, 60.000] with new limits [-60.000, 160.000]
hvBiasVoltage: FREE4 HV2 Bias Voltage measured as 123.85 and within the required range of [-60.0, 160.0]
hvBiasVoltage: FREE5 HV2 Bias Voltage measured as 32.19 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE6 HV2 Bias Voltage measured as 32.76 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE7 HV2 Bias Voltage measured as 48.15 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE8 HV2 Bias Voltage measured as 4.21 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE9 HV2 Bias Voltage measured as 40.04 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE10 HV2 Bias Voltage measured as -36.25 and within the required range of [-60.0, 60.0]
hvBiasVoltage: FREE11 HV2 Bias Voltage measured as 2.78 and within the required range of [-60.0, 60.0]
:
Power of Tkr HV Command: Disabling HV for Trackers [0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15]...
Power of Tkr HV Command: Verified TKR bias voltage change
:
hvBiasVoltage: TKR0 HV0 Bias Voltage measured as 0.31 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR0 HV1 Bias Voltage measured as 25.22 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR1 HV0 Bias Voltage measured as 0.25 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR1 HV1 Bias Voltage measured as 25.10 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR2 HV0 Bias Voltage measured as 0.18 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR2 HV1 Bias Voltage measured as 24.91 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR3 HV0 Bias Voltage measured as 0.31 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR3 HV1 Bias Voltage measured as 24.97 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR4 HV0 Bias Voltage measured as 0.25 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR4 HV1 Bias Voltage measured as 25.03 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR5 HV0 Bias Voltage measured as 0.25 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR5 HV1 Bias Voltage measured as 25.10 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR6 HV0 Bias Voltage measured as 0.49 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR6 HV1 Bias Voltage measured as 24.97 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR7 HV0 Bias Voltage measured as 0.18 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR7 HV1 Bias Voltage measured as 24.97 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR8 HV0 Bias Voltage measured as 0.18 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR8 HV1 Bias Voltage measured as 24.97 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR9 HV0 Bias Voltage measured as 0.25 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKR9 HV1 Bias Voltage measured as 25.10 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKRA HV0 Bias Voltage measured as 0.37 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKRA HV1 Bias Voltage measured as 25.22 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKRB HV0 Bias Voltage measured as 0.25 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKRB HV1 Bias Voltage measured as 25.03 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKRC HV0 Bias Voltage measured as 0.31 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKRC HV1 Bias Voltage measured as 25.16 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKRD HV0 Bias Voltage measured as 0.18 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKRD HV1 Bias Voltage measured as 25.03 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKRE HV0 Bias Voltage measured as 0.25 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKRE HV1 Bias Voltage measured as 25.16 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKRF HV0 Bias Voltage measured as 0.37 and within the required range of [-0.0, 110.0]
hvBiasVoltage: TKRF HV1 Bias Voltage measured as 24.91 and within the required range of [-0.0, 110.0]
:
Power of CAL HV Command: Disabling HV for Calorimeters [0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15]...
Power of CAL HV Command: Verified CAL bias voltage change
:
hvBiasVoltage: CAL0 HV0 Bias Voltage measured as 0.31 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL0 HV1 Bias Voltage measured as 24.79 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL1 HV0 Bias Voltage measured as 0.18 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL1 HV1 Bias Voltage measured as 24.97 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL2 HV0 Bias Voltage measured as 0.12 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL2 HV1 Bias Voltage measured as 24.91 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL3 HV0 Bias Voltage measured as 0.18 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL3 HV1 Bias Voltage measured as 24.85 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL4 HV0 Bias Voltage measured as 0.18 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL4 HV1 Bias Voltage measured as 24.91 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL5 HV0 Bias Voltage measured as 0.25 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL5 HV1 Bias Voltage measured as 24.73 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL6 HV0 Bias Voltage measured as 0.18 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL6 HV1 Bias Voltage measured as 24.85 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL7 HV0 Bias Voltage measured as 0.43 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL7 HV1 Bias Voltage measured as 24.85 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL8 HV0 Bias Voltage measured as 0.25 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL8 HV1 Bias Voltage measured as 24.97 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL9 HV0 Bias Voltage measured as 0.25 and within the required range of [0.0, 80.0]
hvBiasVoltage: CAL9 HV1 Bias Voltage measured as 24.85 and within the required range of [0.0, 80.0]
hvBiasVoltage: CALA HV0 Bias Voltage measured as 0.25 and within the required range of [0.0, 80.0]
hvBiasVoltage: CALA HV1 Bias Voltage measured as 25.03 and within the required range of [0.0, 80.0]
hvBiasVoltage: CALB HV0 Bias Voltage measured as 0.31 and within the required range of [0.0, 80.0]
hvBiasVoltage: CALB HV1 Bias Voltage measured as 24.79 and within the required range of [0.0, 80.0]
hvBiasVoltage: CALC HV0 Bias Voltage measured as 0.18 and within the required range of [0.0, 80.0]
hvBiasVoltage: CALC HV1 Bias Voltage measured as 25.03 and within the required range of [0.0, 80.0]
hvBiasVoltage: CALD HV0 Bias Voltage measured as 0.18 and within the required range of [0.0, 80.0]
hvBiasVoltage: CALD HV1 Bias Voltage measured as 24.91 and within the required range of [0.0, 80.0]
hvBiasVoltage: CALE HV0 Bias Voltage measured as 0.49 and within the required range of [0.0, 80.0]
hvBiasVoltage: CALE HV1 Bias Voltage measured as 24.97 and within the required range of [0.0, 80.0]
hvBiasVoltage: CALF HV0 Bias Voltage measured as 0.18 and within the required range of [0.0, 80.0]
hvBiasVoltage: CALF HV1 Bias Voltage measured as 24.79 and within the required range of [0.0, 80.0]