siuTemp: SIU 1 temperature 34.47C is within [15.0, 50.0]
:
siuFeedVoltage: SIU 1 feed voltage 28.47V is within [27.0, 29.0]
siuVoltage: SIU 1 3.3/5V voltage 2.34V is within [1.7, 2.5]
siuMemCheck: SIU 1 Memory Check passed.
siuCommCheck: SIU 1 Comm Check passed.
siuBootTlm: SIU boot telemetry received.
siuTemp: SIU 1 temperature 36.02C is within [15.0, 50.0]
:
siuVoltage: SIU 1 3.3/5V voltage 2.33V is within [1.7, 2.5]
siuMemCheck: SIU 1 Memory Check passed.
siuCommCheck: SIU 1 Comm Check passed.
siuBootTlm: SIU boot telemetry received.
siuTemp: SIU 1 temperature 36.12C is within [15.0, 50.0]
siuTemp: Sending secondary boot command to SIU 1 using flags hi=0x9400, lo=0xc000 ...
:
siuTemp: Waiting 30 seconds for the SIU 1 secondary boot code load to complete...
latHskTlm: LAT housekeeping telemetry received.
siuTemp: SIU 1 temperature 34.47C is within [15.0, 50.0]
:
pduTemp: PDU temperature 24.22C is within [15.0, 50.0]
:
daqFeedVoltage: DAQ feed voltage 28.12V is within [27.0, 29.0]
pduTemp: PDU temperature 24.08C is within [15.0, 50.0]
pduVoltage: PDU 0 3.3Vvoltage -0.02V is within [-1.0, 6.0]
readDaqFeedCurrent: Read the DAQ feed current as 0.00A
:
daqFeedVoltage: DAQ feed voltage 28.22V is within [27.0, 29.0]
pduTemp: PDU temperature 23.74C is within [15.0, 50.0]
gasuTemp: GASU temperature 24.22C is within [15.0, 50.0]
gasu33V: Checking if dwell telemetry is in range [3.000, 3.600] for payload L_DAQ_P_EBM33V, values [1.01, 3.32, 3.32, 3.35, 3.28] (starting with index:2, margin:0)
gasu33V: Dwell telemetry for payload L_DAQ_P_EBM33V are within [3.000, 3.600]
daqFeedVoltage: Checking if dwell telemetry is in range [27.000, 29.000] for payload VSC_RBPU_DAQ_V, values [28.27, 28.47, 28.47, 28.12, 28.32] (starting with index:2, margin:0)
daqFeedVoltage: Dwell telemetry for payload VSC_RBPU_DAQ_V are within [27.000, 29.000]
gasuTemp: Checking if dwell telemetry is in range [15.000, 50.000] for payload L_DAQ_P_GASU_T, values [23.74, 23.54, 23.27, 24.08, 24.01] (starting with index:2, margin:0)
gasuTemp: Dwell telemetry for payload L_DAQ_P_GASU_T are within [15.000, 50.000]
pduVoltage: Checking if dwell telemetry is in range [0.000, 6.000] for payload L_DAQ_P_PDU_V, values [-0.02, 3.34, 3.37, 3.36, 3.36] (starting with index:2, margin:0)
pduVoltage: Dwell telemetry for payload L_DAQ_P_PDU_V are within [0.000, 6.000]
pduTemp: Checking if dwell telemetry is in range [15.000, 50.000] for payload L_DAQ_P_PDU_T, values [23.61, 24.01, 23.67, 24.01, 24.01] (starting with index:2, margin:0)
pduTemp: Dwell telemetry for payload L_DAQ_P_PDU_T are within [15.000, 50.000]
gasu25V: Checking if dwell telemetry is in range [2.000, 2.600] for payload L_DAQ_P_EBM25V, values [0.04, 2.48, 2.51, 2.46, 2.45] (starting with index:2, margin:0)
gasu25V: Dwell telemetry for payload L_DAQ_P_EBM25V are within [2.000, 2.600]
gasu25V: Checking if dwell telemetry is in range [2.000, 2.600] for payload L_DAQ_P_GEM25V, values [-0.04, 2.42, 2.46, 2.50, 2.50] (starting with index:2, margin:0)
gasu25V: Dwell telemetry for payload L_DAQ_P_GEM25V are within [2.000, 2.600]
gasu33V: Checking if dwell telemetry is in range [3.000, 3.600] for payload L_DAQ_P_GEM33V, values [1.05, 3.32, 3.32, 3.28, 3.28] (starting with index:2, margin:0)
gasu33V: Dwell telemetry for payload L_DAQ_P_GEM33V are within [3.000, 3.600]
daqCurrentDelta: Checking if dwell telemetry is in range [-1.000, 1.500] for payload VSC_RBPU_DAQ_C, values [-0.39, 0.44, 0.34, 0.29, 0.54] (starting with index:2, margin:0)
daqCurrentDelta: Dwell telemetry for payload VSC_RBPU_DAQ_C are within [-1.000, 1.500]
:
daqFeedVoltage: DAQ feed voltage 28.71V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta 0.73A is within [-1.0, 1.5]
pduTemp: PDU temperature 24.29C is within [15.0, 50.0]
pduVoltage: PDU 0 3.3Vvoltage 3.37V is within [0.0, 6.0]
gasuTemp: GASU temperature 24.22C is within [15.0, 50.0]
gasuVoltages: AEM/EBM 3.3V voltage 3.36V is within [3.0, 3.6000000000000001]
gasuVoltages: AEM/EBM 2.5V voltage 2.46V is within [2.0, 2.6000000000000001]
gasuVoltages: CRU/GEM 3.3V voltage 3.32V is within [3.0, 3.6000000000000001]
gasuVoltages: CRU/GEM 2.5V voltage 2.42V is within [2.0, 2.6000000000000001]
readDaqFeedCurrent: Read the DAQ feed current as 0.34A
:
daqFeedVoltage: DAQ feed voltage 28.08V is within [27.0, 29.0]
epuTemp: PDU 0 EPU 0 temperature measured as 21.39C and within the required range of [15.0, 50.0]
epuPwrMgt: Checking if dwell telemetry is in range [1.000, 1.000] for payload LHKP0EPU0PM, values [0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00] (starting with index:8, margin:5)
epuPwrMgt: Dwell telemetry for payload LHKP0EPU0PM are within [1.000, 1.000]
epuTemp: Checking if dwell telemetry is in range [15.000, 50.000] for payload LHKP0EPU0T, values [21.39, 21.39, 21.39, 21.39, 21.39, 21.39, 21.39, 21.39, 21.39, 21.39, 21.39, 21.39, 21.39, 21.39, 21.39, 21.39, 21.39, 21.39, 21.39, 21.39] (starting with index:8, margin:5)
epuTemp: Dwell telemetry for payload LHKP0EPU0T are within [15.000, 50.000]
epuCnvt: Checking if dwell telemetry is in range [0.000, 0.000] for payload LHKP0EPU0CNVT, values [0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00] (starting with index:8, margin:5)
epuCnvt: Dwell telemetry for payload LHKP0EPU0CNVT are within [0.000, 0.000]
:
daqFeedVoltage: DAQ feed voltage 28.27V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta 0.10A is within [-1.0, 1.0]
epuVoltage: PDU 0 EPU 0 3.3V voltage measured as 2.26V and within the required range of [2.0, 3.5]
epuBootTlm: EPU 0 boot telemetry received.
epuTemp: PDU 0 EPU 0 temperature measured as 21.45C and within the required range of [15.0, 50.0]
readDaqFeedCurrent: Read the DAQ feed current as 0.78A
:
epuVoltage: PDU 0 EPU 0 3.3V voltage measured as 2.26V and within the required range of [2.0, 3.5]
epuTemp: PDU 0 EPU 0 temperature measured as 21.48C and within the required range of [15.0, 50.0]
epuTemp: Sending secondary boot command to EPU 0 using flags hi=0xa800, lo=0xc000 ...
:
epuTemp: Waiting 30 seconds for the EPU 0 secondary boot code load to complete...
epuHskTlm: EPU 0 CPU junction temperature measured as 43 and within the required range of [1, 999]
epuTemp: PDU 0 EPU 0 temperature measured as 21.60C and within the required range of [15.0, 50.0]
:
daqFeedVoltage: DAQ feed voltage 28.27V is within [27.0, 29.0]
epuTemp: PDU 0 EPU 1 temperature measured as 21.09C and within the required range of [15.0, 50.0]
epuPwrMgt: Checking if dwell telemetry is in range [1.000, 1.000] for payload LHKP0EPU1PM, values [0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00] (starting with index:8, margin:5)
epuPwrMgt: Dwell telemetry for payload LHKP0EPU1PM are within [1.000, 1.000]
epuCnvt: Checking if dwell telemetry is in range [0.000, 0.000] for payload LHKP0EPU1CNVT, values [0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00] (starting with index:8, margin:5)
epuCnvt: Dwell telemetry for payload LHKP0EPU1CNVT are within [0.000, 0.000]
epuTemp: Checking if dwell telemetry is in range [15.000, 50.000] for payload LHKP0EPU1T, values [21.09, 21.09, 21.09, 21.09, 21.12, 21.12, 21.12, 21.12, 21.12, 21.12, 21.12, 21.12, 21.12, 21.09, 21.09, 21.09, 21.09, 21.09, 21.09, 21.09] (starting with index:8, margin:5)
epuTemp: Dwell telemetry for payload LHKP0EPU1T are within [15.000, 50.000]
:
daqFeedVoltage: DAQ feed voltage 28.42V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta 0.68A is within [-1.0, 1.0]
epuVoltage: PDU 0 EPU 1 3.3V voltage measured as 2.27V and within the required range of [2.0, 3.5]
epuBootTlm: EPU 1 boot telemetry received.
epuTemp: PDU 0 EPU 1 temperature measured as 21.12C and within the required range of [15.0, 50.0]
readDaqFeedCurrent: Read the DAQ feed current as 1.71A
:
epuVoltage: PDU 0 EPU 1 3.3V voltage measured as 2.27V and within the required range of [2.0, 3.5]
epuTemp: PDU 0 EPU 1 temperature measured as 21.15C and within the required range of [15.0, 50.0]
epuTemp: Sending secondary boot command to EPU 1 using flags hi=0xa800, lo=0xc000 ...
:
epuTemp: Waiting 30 seconds for the EPU 1 secondary boot code load to complete...
epuHskTlm: EPU 1 CPU junction temperature measured as 39 and within the required range of [1, 999]
epuTemp: PDU 0 EPU 1 temperature measured as 21.26C and within the required range of [15.0, 50.0]
:
daqFeedVoltage: DAQ Feed Voltage measured as 28.47 and within the required range of [27.0, 29.0]
temDaqTemp: PDU0, TEM0 DAQ temperature measured as 21.63 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM1 DAQ temperature measured as 21.72 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM2 DAQ temperature measured as 21.70 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM3 DAQ temperature measured as 21.38 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM4 DAQ temperature measured as 22.54 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM5 DAQ temperature measured as 22.94 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM6 DAQ temperature measured as 23.11 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM7 DAQ temperature measured as 22.05 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM8 DAQ temperature measured as 23.18 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM9 DAQ temperature measured as 23.24 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEMA DAQ temperature measured as 23.36 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEMB DAQ temperature measured as 26.24 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEMC DAQ temperature measured as 24.09 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEMD DAQ temperature measured as 24.33 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEME DAQ temperature measured as 24.26 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEMF DAQ temperature measured as 24.19 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM0 TPS temperature measured as 21.63 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM1 TPS temperature measured as 21.97 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM2 TPS temperature measured as 21.85 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM3 TPS temperature measured as 21.50 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM4 TPS temperature measured as 22.68 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM5 TPS temperature measured as 22.87 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM6 TPS temperature measured as 23.11 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM7 TPS temperature measured as 22.23 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM8 TPS temperature measured as 23.36 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM9 TPS temperature measured as 23.64 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMA TPS temperature measured as 23.62 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMB TPS temperature measured as 25.46 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMC TPS temperature measured as 24.16 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMD TPS temperature measured as 24.71 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEME TPS temperature measured as 24.49 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMF TPS temperature measured as 24.37 and within the required range of [15.0, 50.0]
Power On Command: Powering on TEM[0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15] on PDU0...
Power On Command: Verified power on action.
:
daqFeedVoltage: DAQ Feed Voltage measured as 28.08 and within the required range of [27.0, 29.0]
temPsCurrent: Warning: Conversion constant for LDET0TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM0 power supply current measured as -0.45 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET1TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM1 power supply current measured as 1.27 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET2TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM2 power supply current measured as -0.60 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET3TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM3 power supply current measured as -0.66 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET4TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM4 power supply current measured as 0.01 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET5TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM5 power supply current measured as 0.42 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET6TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM6 power supply current measured as -0.12 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET7TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM7 power supply current measured as -0.84 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET8TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM8 power supply current measured as -0.04 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET9TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM9 power supply current measured as 0.06 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETATEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM10 power supply current measured as -0.06 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETBTEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM11 power supply current measured as 1.45 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETCTEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM12 power supply current measured as 0.23 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETDTEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM13 power supply current measured as 0.88 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETETEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM14 power supply current measured as 0.54 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETFTEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM15 power supply current measured as 0.87 and within the required range of [-1.0, 5.0]
temVoltage: TEM0 3.3V measured as 3.40 and within the required range of [3.0, 3.5]
temVoltage: TEM1 3.3V measured as 3.39 and within the required range of [3.0, 3.5]
temVoltage: TEM2 3.3V measured as 3.38 and within the required range of [3.0, 3.5]
temVoltage: TEM3 3.3V measured as 3.39 and within the required range of [3.0, 3.5]
temVoltage: TEM4 3.3V measured as 3.34 and within the required range of [3.0, 3.5]
temVoltage: TEM5 3.3V measured as 3.36 and within the required range of [3.0, 3.5]
temVoltage: TEM6 3.3V measured as 3.34 and within the required range of [3.0, 3.5]
temVoltage: TEM7 3.3V measured as 3.38 and within the required range of [3.0, 3.5]
temVoltage: TEM8 3.3V measured as 3.37 and within the required range of [3.0, 3.5]
temVoltage: TEM9 3.3V measured as 3.37 and within the required range of [3.0, 3.5]
temVoltage: TEMA 3.3V measured as 3.43 and within the required range of [3.0, 3.5]
temVoltage: TEMB 3.3V measured as 3.37 and within the required range of [3.0, 3.5]
temVoltage: TEMC 3.3V measured as 3.40 and within the required range of [3.0, 3.5]
temVoltage: TEMD 3.3V measured as 3.37 and within the required range of [3.0, 3.5]
temVoltage: TEME 3.3V measured as 3.39 and within the required range of [3.0, 3.5]
temVoltage: TEMF 3.3V measured as 3.35 and within the required range of [3.0, 3.5]
temDaqTemp: PDU0, TEM0 DAQ temperature measured as 21.66 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM1 DAQ temperature measured as 21.75 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM2 DAQ temperature measured as 21.70 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM3 DAQ temperature measured as 21.41 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM4 DAQ temperature measured as 22.54 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM5 DAQ temperature measured as 22.94 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM6 DAQ temperature measured as 23.11 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM7 DAQ temperature measured as 22.02 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM8 DAQ temperature measured as 23.18 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEM9 DAQ temperature measured as 23.27 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEMA DAQ temperature measured as 23.36 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEMB DAQ temperature measured as 26.27 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEMC DAQ temperature measured as 24.09 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEMD DAQ temperature measured as 24.36 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEME DAQ temperature measured as 24.29 and within the required range of [15.0, 50.0]
temDaqTemp: PDU0, TEMF DAQ temperature measured as 24.19 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM0 TPS temperature measured as 21.63 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM1 TPS temperature measured as 21.97 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM2 TPS temperature measured as 21.85 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM3 TPS temperature measured as 21.50 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM4 TPS temperature measured as 22.68 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM5 TPS temperature measured as 22.87 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM6 TPS temperature measured as 23.08 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM7 TPS temperature measured as 22.23 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM8 TPS temperature measured as 23.39 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM9 TPS temperature measured as 23.64 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMA TPS temperature measured as 23.62 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMB TPS temperature measured as 25.42 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMC TPS temperature measured as 24.19 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMD TPS temperature measured as 24.71 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEME TPS temperature measured as 24.49 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMF TPS temperature measured as 24.34 and within the required range of [15.0, 50.0]
daqFeedCurrentDelta: DAQ Feed Current Delta measured as 2.10 and within the required range of [1.0, 2.5]
:
temPsTemp: PDU0, TEM0 TPS temperature measured as 21.66 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM1 TPS temperature measured as 21.97 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM2 TPS temperature measured as 21.85 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM3 TPS temperature measured as 21.53 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM4 TPS temperature measured as 22.68 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM5 TPS temperature measured as 22.87 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM6 TPS temperature measured as 23.08 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM7 TPS temperature measured as 22.26 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM8 TPS temperature measured as 23.36 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM9 TPS temperature measured as 23.64 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMA TPS temperature measured as 23.62 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMB TPS temperature measured as 25.42 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMC TPS temperature measured as 24.16 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMD TPS temperature measured as 24.71 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEME TPS temperature measured as 24.49 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMF TPS temperature measured as 24.37 and within the required range of [15.0, 50.0]
Power On Command: Powering on CAL[0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15] ...
Power On Command: Verified power on action.
:
daqFeedVoltage: DAQ Feed Voltage measured as 27.93 and within the required range of [27.0, 29.0]
temPsCurrent: Warning: Conversion constant for LDET0TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM0 power supply current measured as -0.17 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET1TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM1 power supply current measured as 1.54 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET2TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM2 power supply current measured as -0.28 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET3TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM3 power supply current measured as -0.33 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET4TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM4 power supply current measured as 0.30 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET5TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM5 power supply current measured as 0.65 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET6TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM6 power supply current measured as 0.12 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET7TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM7 power supply current measured as -0.60 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET8TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM8 power supply current measured as 0.24 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET9TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM9 power supply current measured as 0.30 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETATEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM10 power supply current measured as 0.14 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETBTEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM11 power supply current measured as 1.69 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETCTEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM12 power supply current measured as 0.50 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETDTEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM13 power supply current measured as 1.20 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETETEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM14 power supply current measured as 0.74 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETFTEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM15 power supply current measured as 1.15 and within the required range of [-1.0, 5.0]
cal33V: TEM0 CAL Digital 3.3V measured as 3.36 and within the required range of [3.0, 3.5]
cal33V: TEM0 CAL Analog 3.3V measured as 3.39 and within the required range of [3.0, 3.5]
cal33V: TEM1 CAL Digital 3.3V measured as 3.35 and within the required range of [3.0, 3.5]
cal33V: TEM1 CAL Analog 3.3V measured as 3.36 and within the required range of [3.0, 3.5]
cal33V: TEM2 CAL Digital 3.3V measured as 3.33 and within the required range of [3.0, 3.5]
cal33V: TEM2 CAL Analog 3.3V measured as 3.35 and within the required range of [3.0, 3.5]
cal33V: TEM3 CAL Digital 3.3V measured as 3.35 and within the required range of [3.0, 3.5]
cal33V: TEM3 CAL Analog 3.3V measured as 3.36 and within the required range of [3.0, 3.5]
cal33V: TEM4 CAL Digital 3.3V measured as 3.35 and within the required range of [3.0, 3.5]
cal33V: TEM4 CAL Analog 3.3V measured as 3.36 and within the required range of [3.0, 3.5]
cal33V: TEM5 CAL Digital 3.3V measured as 3.35 and within the required range of [3.0, 3.5]
cal33V: TEM5 CAL Analog 3.3V measured as 3.33 and within the required range of [3.0, 3.5]
cal33V: TEM6 CAL Digital 3.3V measured as 3.36 and within the required range of [3.0, 3.5]
cal33V: TEM6 CAL Analog 3.3V measured as 3.32 and within the required range of [3.0, 3.5]
cal33V: TEM7 CAL Digital 3.3V measured as 3.34 and within the required range of [3.0, 3.5]
cal33V: TEM7 CAL Analog 3.3V measured as 3.35 and within the required range of [3.0, 3.5]
cal33V: TEM8 CAL Digital 3.3V measured as 3.36 and within the required range of [3.0, 3.5]
cal33V: TEM8 CAL Analog 3.3V measured as 3.36 and within the required range of [3.0, 3.5]
cal33V: TEM9 CAL Digital 3.3V measured as 3.35 and within the required range of [3.0, 3.5]
cal33V: TEM9 CAL Analog 3.3V measured as 3.34 and within the required range of [3.0, 3.5]
cal33V: TEMA CAL Digital 3.3V measured as 3.36 and within the required range of [3.0, 3.5]
cal33V: TEMA CAL Analog 3.3V measured as 3.34 and within the required range of [3.0, 3.5]
cal33V: TEMB CAL Digital 3.3V measured as 3.32 and within the required range of [3.0, 3.5]
cal33V: TEMB CAL Analog 3.3V measured as 3.32 and within the required range of [3.0, 3.5]
cal33V: TEMC CAL Digital 3.3V measured as 3.44 and within the required range of [3.0, 3.5]
cal33V: TEMC CAL Analog 3.3V measured as 3.36 and within the required range of [3.0, 3.5]
cal33V: TEMD CAL Digital 3.3V measured as 3.39 and within the required range of [3.0, 3.5]
cal33V: TEMD CAL Analog 3.3V measured as 3.36 and within the required range of [3.0, 3.5]
cal33V: TEME CAL Digital 3.3V measured as 3.36 and within the required range of [3.0, 3.5]
cal33V: TEME CAL Analog 3.3V measured as 3.38 and within the required range of [3.0, 3.5]
cal33V: TEMF CAL Digital 3.3V measured as 3.35 and within the required range of [3.0, 3.5]
cal33V: TEMF CAL Analog 3.3V measured as 3.38 and within the required range of [3.0, 3.5]
daqFeedCurrentDelta: DAQ Feed Current Delta measured as 3.66 and within the required range of [3.0, 6.0]
:
temPsTemp: PDU0, TEM0 TPS temperature measured as 21.66 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM1 TPS temperature measured as 21.97 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM2 TPS temperature measured as 21.85 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM3 TPS temperature measured as 21.53 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM4 TPS temperature measured as 22.68 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM5 TPS temperature measured as 22.87 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM6 TPS temperature measured as 23.11 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM7 TPS temperature measured as 22.26 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM8 TPS temperature measured as 23.39 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEM9 TPS temperature measured as 23.64 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMA TPS temperature measured as 23.62 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMB TPS temperature measured as 25.42 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMC TPS temperature measured as 24.19 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMD TPS temperature measured as 24.71 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEME TPS temperature measured as 24.52 and within the required range of [15.0, 50.0]
temPsTemp: PDU0, TEMF TPS temperature measured as 24.34 and within the required range of [15.0, 50.0]
Power On Command: Powering on TKR[0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15]...
Power On Command: Verified power on action.
:
daqFeedVoltage: DAQ Feed Voltage measured as 28.17 and within the required range of [27.0, 29.0]
temPsCurrent: Warning: Conversion constant for LDET0TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM0 power supply current measured as 0.32 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET1TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM1 power supply current measured as 2.09 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET2TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM2 power supply current measured as 0.33 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET3TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM3 power supply current measured as 0.15 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET4TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM4 power supply current measured as 0.83 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET5TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM5 power supply current measured as 1.21 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET6TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM6 power supply current measured as 0.64 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET7TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM7 power supply current measured as -0.03 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET8TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM8 power supply current measured as 0.80 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDET9TEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM9 power supply current measured as 0.85 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETATEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM10 power supply current measured as 0.75 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETBTEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM11 power supply current measured as 2.25 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETCTEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM12 power supply current measured as 1.06 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETDTEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM13 power supply current measured as 1.72 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETETEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM14 power supply current measured as 1.26 and within the required range of [-1.0, 5.0]
temPsCurrent: Warning: Conversion constant for LDETFTEM28I was not in database, using the data from the configuration file
temPsCurrent: TEM15 power supply current measured as 1.66 and within the required range of [-1.0, 5.0]
tkrVoltage: TEM0 TKR Analog 1.5V measured as 1.45 and within the required range of [1.3, 1.7]
tkrVoltage: TEM0 TKR Digital 2.5V measured as 2.54 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM0 TKR Analog 2.5V measured as 2.58 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM1 TKR Analog 1.5V measured as 1.55 and within the required range of [1.3, 1.7]
tkrVoltage: TEM1 TKR Digital 2.5V measured as 2.63 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM1 TKR Analog 2.5V measured as 2.66 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM2 TKR Analog 1.5V measured as 1.48 and within the required range of [1.3, 1.7]
tkrVoltage: TEM2 TKR Digital 2.5V measured as 2.56 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM2 TKR Analog 2.5V measured as 2.62 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM3 TKR Analog 1.5V measured as 1.49 and within the required range of [1.3, 1.7]
tkrVoltage: TEM3 TKR Digital 2.5V measured as 2.59 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM3 TKR Analog 2.5V measured as 2.61 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM4 TKR Analog 1.5V measured as 1.45 and within the required range of [1.3, 1.7]
tkrVoltage: TEM4 TKR Digital 2.5V measured as 2.60 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM4 TKR Analog 2.5V measured as 2.64 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM5 TKR Analog 1.5V measured as 1.48 and within the required range of [1.3, 1.7]
tkrVoltage: TEM5 TKR Digital 2.5V measured as 2.55 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM5 TKR Analog 2.5V measured as 2.60 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM6 TKR Analog 1.5V measured as 1.46 and within the required range of [1.3, 1.7]
tkrVoltage: TEM6 TKR Digital 2.5V measured as 2.52 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM6 TKR Analog 2.5V measured as 2.59 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM7 TKR Analog 1.5V measured as 1.41 and within the required range of [1.3, 1.7]
tkrVoltage: TEM7 TKR Digital 2.5V measured as 2.57 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM7 TKR Analog 2.5V measured as 2.66 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM8 TKR Analog 1.5V measured as 1.49 and within the required range of [1.3, 1.7]
tkrVoltage: TEM8 TKR Digital 2.5V measured as 2.57 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM8 TKR Analog 2.5V measured as 2.64 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM9 TKR Analog 1.5V measured as 1.55 and within the required range of [1.3, 1.7]
tkrVoltage: TEM9 TKR Digital 2.5V measured as 2.58 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEM9 TKR Analog 2.5V measured as 2.60 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEMA TKR Analog 1.5V measured as 1.45 and within the required range of [1.3, 1.7]
tkrVoltage: TEMA TKR Digital 2.5V measured as 2.57 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEMA TKR Analog 2.5V measured as 2.61 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEMB TKR Analog 1.5V measured as 1.51 and within the required range of [1.3, 1.7]
tkrVoltage: TEMB TKR Digital 2.5V measured as 2.59 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEMB TKR Analog 2.5V measured as 2.59 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEMC TKR Analog 1.5V measured as 1.52 and within the required range of [1.3, 1.7]
tkrVoltage: TEMC TKR Digital 2.5V measured as 2.60 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEMC TKR Analog 2.5V measured as 2.64 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEMD TKR Analog 1.5V measured as 1.45 and within the required range of [1.3, 1.7]
tkrVoltage: TEMD TKR Digital 2.5V measured as 2.58 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEMD TKR Analog 2.5V measured as 2.63 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEME TKR Analog 1.5V measured as 1.49 and within the required range of [1.3, 1.7]
tkrVoltage: TEME TKR Digital 2.5V measured as 2.56 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEME TKR Analog 2.5V measured as 2.62 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEMF TKR Analog 1.5V measured as 1.44 and within the required range of [1.3, 1.7]
tkrVoltage: TEMF TKR Digital 2.5V measured as 2.60 and within the required range of [2.2999999999999998, 3.0]
tkrVoltage: TEMF TKR Analog 2.5V measured as 2.59 and within the required range of [2.2999999999999998, 3.0]
daqFeedCurrentDelta: DAQ Feed Current Delta measured as 8.64 and within the required range of [8.0, 13.0]
:
gasuVoltages: P GASU EBM/AEM 3.3V measured as 3.36 and within the required range of [3.0, 3.6000000000000001]
gasuVoltages: P GASU EBM/AEM 2.5V measured as 2.53 and within the required range of [2.0, 2.6000000000000001]
gasuVoltages: P GASU CRU/GEM 3.3V measured as 3.30 and within the required range of [3.0, 3.6000000000000001]
gasuVoltages: P GASU CRU/GEM 2.5V measured as 2.51 and within the required range of [2.0, 2.6000000000000001]
Power On Command: Powering on free boards [0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11]...
Power On Command: Verified power on action.
:
gasuVoltages: P GASU EBM/AEM 3.3V measured as 3.32 and within the required range of [3.0, 3.6000000000000001]
gasuVoltages: P GASU EBM/AEM 2.5V measured as 2.42 and within the required range of [2.0, 2.6000000000000001]
gasuVoltages: P GASU CRU/GEM 3.3V measured as 3.35 and within the required range of [3.0, 3.6000000000000001]
gasuVoltages: P GASU CRU/GEM 2.5V measured as 2.44 and within the required range of [2.0, 2.6000000000000001]
freeBoardVoltage: FREE0 Voltage measured as 3.70 and within the required range of [3.0, 4.0]
freeBoardVoltage: FREE1 Voltage measured as 3.69 and within the required range of [3.0, 4.0]
freeBoardVoltage: FREE2 Voltage measured as 3.69 and within the required range of [3.0, 4.0]
freeBoardVoltage: FREE3 Voltage measured as 3.70 and within the required range of [3.0, 4.0]
freeBoardVoltage: FREE4 Voltage measured as 3.69 and within the required range of [3.0, 4.0]
freeBoardVoltage: FREE5 Voltage measured as 3.70 and within the required range of [3.0, 4.0]
freeBoardVoltage: FREE6 Voltage measured as 3.68 and within the required range of [3.0, 4.0]
freeBoardVoltage: FREE7 Voltage measured as 3.69 and within the required range of [3.0, 4.0]
freeBoardVoltage: FREE8 Voltage measured as 3.68 and within the required range of [3.0, 4.0]
freeBoardVoltage: FREE9 Voltage measured as 3.68 and within the required range of [3.0, 4.0]
freeBoardVoltage: FREE10 Voltage measured as 3.69 and within the required range of [3.0, 4.0]
freeBoardVoltage: FREE11 Voltage measured as 3.68 and within the required range of [3.0, 4.0]
freeBoardCurrent: FREE 3.3V Current sum measured as 0.00 and within the required range of [0.0, 1.2]
freeBoardTemp: FREE0 Temperature measured as -114.72 and within the required range of [-120.0, 30.0]
freeBoardTemp: FREE1 Temperature measured as -114.72 and within the required range of [-120.0, 30.0]
freeBoardTemp: FREE2 Temperature measured as -114.72 and within the required range of [-120.0, 30.0]
freeBoardTemp: FREE3 Temperature measured as -114.72 and within the required range of [-120.0, 30.0]
freeBoardTemp: FREE4 Temperature measured as -114.72 and within the required range of [-120.0, 30.0]
freeBoardTemp: FREE5 Temperature measured as -114.72 and within the required range of [-120.0, 30.0]
freeBoardTemp: FREE6 Temperature measured as -114.72 and within the required range of [-120.0, 30.0]
freeBoardTemp: FREE7 Temperature measured as -114.72 and within the required range of [-120.0, 30.0]
freeBoardTemp: FREE8 Temperature measured as -114.72 and within the required range of [-120.0, 30.0]
freeBoardTemp: FREE9 Temperature measured as -114.72 and within the required range of [-120.0, 30.0]
freeBoardTemp: FREE10 Temperature measured as -114.72 and within the required range of [-120.0, 30.0]
freeBoardTemp: FREE11 Temperature measured as -114.72 and within the required range of [-120.0, 30.0]