siuFeedVoltage: SIU 1 feed voltage 28.27V is within [27.0, 29.0]
siuFeedCurrent: SIU 1 feed current 0.50A is within [-1.0, 1.0]
siuVoltage: SIU 1 3.3/5V voltage 2.34V is within [0.0, 6.0]
siuBootTlm: SIU boot telemetry received.
:
siuVoltage: SIU 1 3.3/5V voltage 2.34V is within [0.0, 6.0]
siuMemCheck: SIU 1 Memory Check passed.
siuCommCheck: SIU 1 Comm Check passed.
siuBootTlm: SIU boot telemetry received.
siuTemp: SIU 1 temperature 25.41C is within [23.0, 50.0]
siuTemp: Sending secondary boot command to SIU 1 using flags hi=0x5400, lo=0xc000 ...
:
latHskTlm: LAT housekeeping telemetry received.
siuTemp: SIU 1 temperature 25.41C is within [23.0, 50.0]
:
readSiuCurrent: Read the SIU feed current as 0.00A
siuFeedVoltage: SIU 1 feed voltage 0.73V is within [-1.0, 1.0]
siuTemp: SIU 1 temperature 25.92C is within [23.0, 50.0]
:
siuFeedVoltage: SIU 1 feed voltage 28.08V is within [27.0, 29.0]
siuFeedCurrent: SIU 1 feed current 0.51A is within [-1.0, 1.0]
siuVoltage: SIU 1 3.3/5V voltage 2.35V is within [0.0, 6.0]
siuBootTlm: SIU boot telemetry received.
:
readDaqFeedCurrent: Read the DAQ feed current as -0.10A
daqFeedVoltage: DAQ feed voltage -0.05V is within [-1.0, 1.0]
:
daqFeedVoltage: DAQ feed voltage 27.93V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta 0.24A is within [-1.0, 1.0]
pduVoltage: Warning: PDU 1 3.3V voltage -0.00V is not within [0.0, 6.0]
pduVoltage: Warning: enableDaqFeed : Verification - Operator forced test pduVoltage to pass
readDaqFeedCurrent: Read the DAQ feed current as -0.20A
:
daqFeedVoltage: DAQ feed voltage 27.73V is within [27.0, 29.0]
daqFeedVoltage: Starting Power State: Primary PDU is off Redundant PDU is off
daqFeedVoltage: Ending Power State: Primary PDU is off Redundant PDU is on
:
daqFeedVoltage: DAQ feed voltage 27.93V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta 0.15A is within [-1.0, 1.5]
pduVoltage: PDU 1 3.3Vvoltage 3.35V is within [0.0, 6.0]
pduOnVerify: Ending Power State: Redundant PDU is on
readDaqFeedCurrent: Read the DAQ feed current as -0.20A
:
daqFeedVoltage: DAQ feed voltage 27.73V is within [27.0, 29.0]
daqFeedVoltage: Starting Power State: Primary Gasu is off Redundant Gasu is off
daqFeedVoltage: Ending Power State: Primary GASU is on Redundant GASU is off
:
daqFeedVoltage: DAQ feed voltage 28.12V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta 0.83A is within [-1.0, 1.5]
pduVoltage: PDU 1 3.3Vvoltage 3.32V is within [0.0, 6.0]
gasuVoltages: AEM/EBM 3.3V voltage 3.35V is within [3.0, 3.6000000000000001]
gasuVoltages: AEM/EBM 2.5V voltage 2.48V is within [2.0, 2.6000000000000001]
gasuVoltages: CRU/GEM 3.3V voltage 3.35V is within [3.0, 3.6000000000000001]
gasuVoltages: CRU/GEM 2.5V voltage 2.44V is within [2.0, 2.6000000000000001]
readDaqFeedCurrent: Read the DAQ feed current as 0.49A
:
siuVoltage: SIU 1 3.3/5V voltage 2.34V is within [0.0, 6.0]
siuMemCheck: SIU 1 Memory Check passed.
siuCommCheck: SIU 1 Comm Check passed.
siuBootTlm: SIU boot telemetry received.
siuTemp: SIU 1 temperature 27.40C is within [23.0, 50.0]
siuTemp: Sending secondary boot command to SIU 1 using flags hi=0x5400, lo=0xc000 ...
:
latHskTlm: LAT housekeeping telemetry received.
siuTemp: SIU 1 temperature 27.09C is within [23.0, 50.0]
:
daqFeedVoltage: DAQ feed voltage 28.27V is within [27.0, 29.0]
:
daqFeedVoltage: DAQ feed voltage 28.08V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta -0.15A is within [-1.0, 1.5]
pduVoltage: PDU 1 3.3Vvoltage 3.35V is within [0.0, 6.0]
gasuVoltages: AEM/EBM 3.3V voltage 3.34V is within [3.0, 3.6000000000000001]
gasuVoltages: AEM/EBM 2.5V voltage 2.50V is within [2.0, 2.6000000000000001]
gasuVoltages: CRU/GEM 3.3V voltage 3.32V is within [3.0, 3.6000000000000001]
gasuVoltages: CRU/GEM 2.5V voltage 2.46V is within [2.0, 2.6000000000000001]
readDaqFeedCurrent: Read the DAQ feed current as 0.34A
:
daqFeedVoltage: DAQ feed voltage 28.12V is within [27.0, 29.0]
readDaqFeedCurrent: Read the DAQ feed current as 0.20A
epuTemp: PDU 1 EPU 0 temperature measured as 18.80C and within the required range of [-30.0, 45.0]
:
daqFeedVoltage: DAQ feed voltage 27.93V is within [27.0, 29.0]
epuVoltage: PDU 1 EPU 0 3.3V voltage measured as 2.24V and within the required range of [2.0, 3.5]
epuTemp: PDU 1 EPU 0 temperature measured as 19.45C and within the required range of [-30.0, 45.0]
readDaqFeedCurrent: Read the DAQ feed current as 0.93A
:
:
epuVoltage: PDU 1 EPU 0 3.3V voltage measured as 0.01V and within the required range of [0.0, 0.5]
:
daqFeedVoltage: DAQ feed voltage 28.17V is within [27.0, 29.0]
readDaqFeedCurrent: Read the DAQ feed current as 0.59A
temDaqTemp: PDU 1 TEM 0 DAQ board temperature measured as 18.89C and within the required range of [-40.0, 60.0]
temPsTemp: PDU 1 TEM 0 power supply temperature measured as 19.17C and within the required range of [-40.0, 60.0]
:
daqFeedVoltage: DAQ feed voltage 28.03V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta -0.20A is within [-1.0, 1.0]
temPsCurrent: Warning: Conversion constant for LDET0TEM28I was not in the database, using the data from the configuration file
temPsCurrent: TEM 0 power supply current measured as -0.41A and within the required range of [-1.0, 5.0]
temVoltage: TEM 0 3.3V voltage measured as 3.40V and within the required range of [3.0, 3.5]
temDaqTemp: PDU 1 TEM 0 DAQ board temperature measured as 18.97C and within the required range of [-40.0, 60.0]
temPsTemp: PDU 1 TEM 0 power supply temperature measured as 19.20C and within the required range of [-40.0, 60.0]
readDaqFeedCurrent: Read the DAQ feed current as 0.54A
:
daqFeedVoltage: DAQ feed voltage 27.73V is within [27.0, 29.0]
readDaqFeedCurrent: Read the DAQ feed current as 0.34A
temPsTemp: PDU 1 TEM 0 power supply temperature measured as 19.23C and within the required range of [-30.0, 45.0]
calAfeeTemp: TEM 0 CAL AFEE 0 temperature 1 measured as 25.93C and within the required range of [23.0, 40.0]
calAfeeTemp: TEM 0 CAL AFEE 1 temperature 1 measured as 25.49C and within the required range of [23.0, 40.0]
calAfeeTemp: TEM 0 CAL AFEE 2 temperature 1 measured as 26.03C and within the required range of [23.0, 40.0]
calAfeeTemp: TEM 0 CAL AFEE 3 temperature 1 measured as 25.12C and within the required range of [23.0, 40.0]
:
daqFeedVoltage: DAQ feed voltage 27.93V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta 0.49A is within [-1.0, 1.0]
temPsCurrent: Warning: Conversion constant for LDET0TEM28I was not in the database, using the data from the configuration file
temPsCurrent: TEM 0 power supply current measured as -0.17A and within the required range of [-1.0, 5.0]
cal33V: TEM 0 CAL 3.3V digital measured as 3.36V and within the required range of [3.0, 3.5]
cal33V: TEM 0 CAL 3.3V analog measured as 3.38V and within the required range of [3.0, 3.5]
calBias: TEM 0 CAL bias V0 measured as 0.18V and within the required range of [0.0, 80.0]
calBias: TEM 0 CAL bias V1 measured as 25.77V and within the required range of [0.0, 80.0]
calBias: Warning: Conversion constant for LDET0CALBIASI was not in the database, using the data from the configuration file
calBias: TEM 0 CAL bias current measured as 0.01A and within the required range of [-1.0, 6.0]
calAfeeTemp: TEM 0 CAL AFEE 0 temperature 1 measured as 25.96C and within the required range of [23.0, 40.0]
calAfeeTemp: TEM 0 CAL AFEE 1 temperature 1 measured as 25.49C and within the required range of [23.0, 40.0]
calAfeeTemp: TEM 0 CAL AFEE 2 temperature 1 measured as 26.06C and within the required range of [23.0, 40.0]
calAfeeTemp: TEM 0 CAL AFEE 3 temperature 1 measured as 25.19C and within the required range of [23.0, 40.0]
readDaqFeedCurrent: Read the DAQ feed current as 0.59A
:
:
cal33V: TEM 0 CAL 3.3V digital measured as 0.00V and within the required range of [0.0, 0.10000000000000001]
cal33V: TEM 0 CAL 3.3V analog measured as 0.00V and within the required range of [0.0, 0.10000000000000001]
:
daqFeedVoltage: DAQ feed voltage 28.12V is within [27.0, 29.0]
readDaqFeedCurrent: Read the DAQ feed current as 0.24A
temPsTemp: PDU 1 TEM 0 power supply temperature measured as 19.42C and within the required range of [-30.0, 45.0]
tkrTemp: TEM 0 TKR cable 0 temperature 0 measured as 25.46C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 0 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 1 temperature 0 measured as 25.66C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 1 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 2 temperature 0 measured as 24.96C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 2 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 3 temperature 0 measured as 27.03C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 3 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 4 temperature 0 measured as 25.32C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 4 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 5 temperature 0 measured as 26.40C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 5 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 6 temperature 0 measured as 24.80C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 6 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 7 temperature 0 measured as 25.52C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 7 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
:
daqFeedVoltage: DAQ feed voltage 27.73V is within [27.0, 29.0]
daqCurrentDelta: DAQ feed current delta 0.54A is within [-1.0, 1.0]
temPsCurrent: Warning: Conversion constant for LDET0TEM28I was not in the database, using the data from the configuration file
temPsCurrent: TEM 0 power supply current measured as 0.08A and within the required range of [-1.0, 5.0]
tkrVoltage: TEM 0 TKR 1.5V analog measured as 1.44V and within the required range of [0.0, 2.0]
tkrVoltage: TEM 0 TKR 2.5V digital measured as 2.53V and within the required range of [0.0, 3.0]
tkrVoltage: TEM 0 TKR 2.5V analog measured as 2.57V and within the required range of [0.0, 3.0]
tkrBias: TEM 0 TKR bias V0 measured as 0.25V and within the required range of [0.0, 100.0]
tkrBias: TEM 0 TKR bias V1 measured as 26.02V and within the required range of [0.0, 100.0]
tkrBias: Warning: Conversion constant for LDET0TKRBIASI was not in the database, using the data from the configuration file
tkrBias: TEM 0 TKR bias current measured as -0.00A and within the required range of [-1.0, 10.0]
tkrTemp: TEM 0 TKR cable 0 temperature 0 measured as 25.46C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 0 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 1 temperature 0 measured as 25.69C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 1 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 2 temperature 0 measured as 24.96C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 2 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 3 temperature 0 measured as 27.06C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 3 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 4 temperature 0 measured as 25.32C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 4 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 5 temperature 0 measured as 26.44C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 5 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 6 temperature 0 measured as 24.80C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 6 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 7 temperature 0 measured as 25.69C and within the required range of [-123.0, 40.0]
tkrTemp: TEM 0 TKR cable 7 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]
readDaqFeedCurrent: Read the DAQ feed current as 0.78A
:
stopTkrPrompt: Warning: Unhandled test: stopTkrPrompt in powerOffTkr Action
:
tkrVoltage: TEM 0 TKR 1.5V analog measured as 0.00V and within the required range of [0.0, 0.10000000000000001]
tkrVoltage: TEM 0 TKR 2.5V digital measured as 0.00V and within the required range of [0.0, 0.10000000000000001]
tkrVoltage: TEM 0 TKR 2.5V analog measured as 0.00V and within the required range of [0.0, 0.10000000000000001]
:
stopTemPrompt: Warning: Unhandled test: stopTemPrompt in powerOffTem Action
:
temVoltage: TEM 0 3.3V voltage measured as 1.14V and within the required range of [0.0, 2.0]
:
gasuVoltages: AEM/EBM 3.3V voltage 3.28V is within [3.0, 3.6000000000000001]
gasuVoltages: AEM/EBM 2.5V voltage 2.50V is within [2.0, 2.6000000000000001]
:
gasuVoltages: AEM/EBM 3.3V voltage 3.30V is within [3.0, 3.6000000000000001]
gasuVoltages: AEM/EBM 2.5V voltage 2.51V is within [2.0, 2.6000000000000001]
freeBoardVoltage: AEM free board 0 voltage measured as 0.00V and within the required range of [0.0, 0.10000000000000001]
freeBoardCurrentDelta: Warning: Can not find a previous free board current measurement, caching it now...
freeBoardCurrentDelta: Read the free board current as 0.00A
freeBoardCurrentDelta: Free board current delta 0.00A is within [0.0, 0.90000000000000002]
freeBoardTemp: AEM free board 0 temperature measured as -114.72C and within the required range of [-120.0, 30.0]
:
gasuVoltages: AEM/EBM 3.3V voltage 3.35V is within [3.0, 3.6000000000000001]
gasuVoltages: AEM/EBM 2.5V voltage 2.46V is within [2.0, 2.6000000000000001]
:
gasuVoltages: AEM/EBM 3.3V voltage 3.28V is within [3.0, 3.6000000000000001]
gasuVoltages: AEM/EBM 2.5V voltage 2.46V is within [2.0, 2.6000000000000001]
freeBoardVoltage: AEM free board 0 voltage measured as 3.71V and within the required range of [3.0, 3.7999999999999998]
freeBoardCurrentDelta: Free board current delta 0.00A is within [0.0, 0.90000000000000002]
freeBoardTemp: AEM free board 0 temperature measured as -114.72C and within the required range of [-120.0, 30.0]
:
:
gasuVoltages: AEM/EBM 3.3V voltage 3.36V is within [3.0, 3.6000000000000001]
gasuVoltages: AEM/EBM 2.5V voltage 2.53V is within [2.0, 2.6000000000000001]
freeBoardVoltage: AEM free board 0 voltage measured as 0.00V and within the required range of [-0.10000000000000001, 0.80000000000000004]
:
freeBoardVoltage: AEM free board 0 voltage measured as 0.00V and within the required range of [-0.10000000000000001, 0.80000000000000004]
:
:
: