LAT03x - LAT EPS Performance Test [801000089]

 

 

 

 

 

 

 

EpsPerformance
LAT03x - LAT EPS Performance Test

Sun Apr 9 18:13:19 2006

 

 

 

 

 

 

 

Hardware Configuration

AA

AA

Primary

Primary

Primary

0

1

1

Redundant

Test Summary

tbEpsPerformance.cfg

1.3

L00-16-00

801000089

801000089_rcReport.xml

Start Up Step Prerequisite Verification
Primary SIU boot PASSED PASSED
Secondary SIU boot PASSED PASSED
Primary SIU boot 2 PASSED PASSED
Enable DAQ Feed PASSED PASSED
Power On PDU PASSED PASSED
Power On GASU PASSED PASSED
Secondary SIU boot 2 PASSED PASSED
Main Feed On PASSED PASSED
Power On EPU A PASSED PASSED
Power Off EPU A PASSED PASSED
Power On TEM 0 PASSED PASSED
Power On CAL 0 PASSED PASSED
Power Off CAL 0 PASSED PASSED
Power On TKR 0 PASSED PASSED
Power Off TKR 0 PASSED PASSED
Power Off TEM 0 PASSED PASSED
Power On AEM PASSED PASSED
Power On ACD free board 0 PASSED PASSED
Power Off ACD Free Board 0 PASSED PASSED
Power Off AEM PASSED PASSED
Power Off GASU and PDU PASSED PASSED

PASSED

Primary SIU boot

siuFeedVoltage: SIU 1 feed voltage 28.27V is within [27.0, 29.0]

siuFeedCurrent: SIU 1 feed current 0.50A is within [-1.0, 1.0]

siuVoltage: SIU 1 3.3/5V voltage 2.34V is within [0.0, 6.0]

siuBootTlm: SIU boot telemetry received.

Secondary SIU boot

siuVoltage: SIU 1 3.3/5V voltage 2.34V is within [0.0, 6.0]

siuMemCheck: SIU 1 Memory Check passed.

siuCommCheck: SIU 1 Comm Check passed.

siuBootTlm: SIU boot telemetry received.

siuTemp: SIU 1 temperature 25.41C is within [23.0, 50.0]

siuTemp: Sending secondary boot command to SIU 1 using flags hi=0x5400, lo=0xc000 ...

latHskTlm: LAT housekeeping telemetry received.

siuTemp: SIU 1 temperature 25.41C is within [23.0, 50.0]

Primary SIU boot 2

readSiuCurrent: Read the SIU feed current as 0.00A

siuFeedVoltage: SIU 1 feed voltage 0.73V is within [-1.0, 1.0]

siuTemp: SIU 1 temperature 25.92C is within [23.0, 50.0]

siuFeedVoltage: SIU 1 feed voltage 28.08V is within [27.0, 29.0]

siuFeedCurrent: SIU 1 feed current 0.51A is within [-1.0, 1.0]

siuVoltage: SIU 1 3.3/5V voltage 2.35V is within [0.0, 6.0]

siuBootTlm: SIU boot telemetry received.

Enable DAQ Feed

readDaqFeedCurrent: Read the DAQ feed current as -0.10A

daqFeedVoltage: DAQ feed voltage -0.05V is within [-1.0, 1.0]

daqFeedVoltage: DAQ feed voltage 27.93V is within [27.0, 29.0]

daqCurrentDelta: DAQ feed current delta 0.24A is within [-1.0, 1.0]

pduVoltage: Warning: PDU 1 3.3V voltage -0.00V is not within [0.0, 6.0]

pduVoltage: Warning: enableDaqFeed : Verification - Operator forced test pduVoltage to pass

readDaqFeedCurrent: Read the DAQ feed current as -0.20A

Power On PDU

daqFeedVoltage: DAQ feed voltage 27.73V is within [27.0, 29.0]

daqFeedVoltage: Starting Power State: Primary PDU is off Redundant PDU is off

daqFeedVoltage: Ending Power State: Primary PDU is off Redundant PDU is on

daqFeedVoltage: DAQ feed voltage 27.93V is within [27.0, 29.0]

daqCurrentDelta: DAQ feed current delta 0.15A is within [-1.0, 1.5]

pduVoltage: PDU 1 3.3Vvoltage 3.35V is within [0.0, 6.0]

pduOnVerify: Ending Power State: Redundant PDU is on

readDaqFeedCurrent: Read the DAQ feed current as -0.20A

Power On GASU

daqFeedVoltage: DAQ feed voltage 27.73V is within [27.0, 29.0]

daqFeedVoltage: Starting Power State: Primary Gasu is off Redundant Gasu is off

daqFeedVoltage: Ending Power State: Primary GASU is on Redundant GASU is off

daqFeedVoltage: DAQ feed voltage 28.12V is within [27.0, 29.0]

daqCurrentDelta: DAQ feed current delta 0.83A is within [-1.0, 1.5]

pduVoltage: PDU 1 3.3Vvoltage 3.32V is within [0.0, 6.0]

gasuVoltages: AEM/EBM 3.3V voltage 3.35V is within [3.0, 3.6000000000000001]

gasuVoltages: AEM/EBM 2.5V voltage 2.48V is within [2.0, 2.6000000000000001]

gasuVoltages: CRU/GEM 3.3V voltage 3.35V is within [3.0, 3.6000000000000001]

gasuVoltages: CRU/GEM 2.5V voltage 2.44V is within [2.0, 2.6000000000000001]

readDaqFeedCurrent: Read the DAQ feed current as 0.49A

Secondary SIU boot 2

siuVoltage: SIU 1 3.3/5V voltage 2.34V is within [0.0, 6.0]

siuMemCheck: SIU 1 Memory Check passed.

siuCommCheck: SIU 1 Comm Check passed.

siuBootTlm: SIU boot telemetry received.

siuTemp: SIU 1 temperature 27.40C is within [23.0, 50.0]

siuTemp: Sending secondary boot command to SIU 1 using flags hi=0x5400, lo=0xc000 ...

latHskTlm: LAT housekeeping telemetry received.

siuTemp: SIU 1 temperature 27.09C is within [23.0, 50.0]

Main Feed On

daqFeedVoltage: DAQ feed voltage 28.27V is within [27.0, 29.0]

daqFeedVoltage: DAQ feed voltage 28.08V is within [27.0, 29.0]

daqCurrentDelta: DAQ feed current delta -0.15A is within [-1.0, 1.5]

pduVoltage: PDU 1 3.3Vvoltage 3.35V is within [0.0, 6.0]

gasuVoltages: AEM/EBM 3.3V voltage 3.34V is within [3.0, 3.6000000000000001]

gasuVoltages: AEM/EBM 2.5V voltage 2.50V is within [2.0, 2.6000000000000001]

gasuVoltages: CRU/GEM 3.3V voltage 3.32V is within [3.0, 3.6000000000000001]

gasuVoltages: CRU/GEM 2.5V voltage 2.46V is within [2.0, 2.6000000000000001]

readDaqFeedCurrent: Read the DAQ feed current as 0.34A

Power On EPU A

daqFeedVoltage: DAQ feed voltage 28.12V is within [27.0, 29.0]

readDaqFeedCurrent: Read the DAQ feed current as 0.20A

epuTemp: PDU 1 EPU 0 temperature measured as 18.80C and within the required range of [-30.0, 45.0]

daqFeedVoltage: DAQ feed voltage 27.93V is within [27.0, 29.0]

epuVoltage: PDU 1 EPU 0 3.3V voltage measured as 2.24V and within the required range of [2.0, 3.5]

epuTemp: PDU 1 EPU 0 temperature measured as 19.45C and within the required range of [-30.0, 45.0]

readDaqFeedCurrent: Read the DAQ feed current as 0.93A

Power Off EPU A

epuVoltage: PDU 1 EPU 0 3.3V voltage measured as 0.01V and within the required range of [0.0, 0.5]

Power On TEM 0

daqFeedVoltage: DAQ feed voltage 28.17V is within [27.0, 29.0]

readDaqFeedCurrent: Read the DAQ feed current as 0.59A

temDaqTemp: PDU 1 TEM 0 DAQ board temperature measured as 18.89C and within the required range of [-40.0, 60.0]

temPsTemp: PDU 1 TEM 0 power supply temperature measured as 19.17C and within the required range of [-40.0, 60.0]

daqFeedVoltage: DAQ feed voltage 28.03V is within [27.0, 29.0]

daqCurrentDelta: DAQ feed current delta -0.20A is within [-1.0, 1.0]

temPsCurrent: Warning: Conversion constant for LDET0TEM28I was not in the database, using the data from the configuration file

temPsCurrent: TEM 0 power supply current measured as -0.41A and within the required range of [-1.0, 5.0]

temVoltage: TEM 0 3.3V voltage measured as 3.40V and within the required range of [3.0, 3.5]

temDaqTemp: PDU 1 TEM 0 DAQ board temperature measured as 18.97C and within the required range of [-40.0, 60.0]

temPsTemp: PDU 1 TEM 0 power supply temperature measured as 19.20C and within the required range of [-40.0, 60.0]

readDaqFeedCurrent: Read the DAQ feed current as 0.54A

Power On CAL 0

daqFeedVoltage: DAQ feed voltage 27.73V is within [27.0, 29.0]

readDaqFeedCurrent: Read the DAQ feed current as 0.34A

temPsTemp: PDU 1 TEM 0 power supply temperature measured as 19.23C and within the required range of [-30.0, 45.0]

calAfeeTemp: TEM 0 CAL AFEE 0 temperature 1 measured as 25.93C and within the required range of [23.0, 40.0]

calAfeeTemp: TEM 0 CAL AFEE 1 temperature 1 measured as 25.49C and within the required range of [23.0, 40.0]

calAfeeTemp: TEM 0 CAL AFEE 2 temperature 1 measured as 26.03C and within the required range of [23.0, 40.0]

calAfeeTemp: TEM 0 CAL AFEE 3 temperature 1 measured as 25.12C and within the required range of [23.0, 40.0]

daqFeedVoltage: DAQ feed voltage 27.93V is within [27.0, 29.0]

daqCurrentDelta: DAQ feed current delta 0.49A is within [-1.0, 1.0]

temPsCurrent: Warning: Conversion constant for LDET0TEM28I was not in the database, using the data from the configuration file

temPsCurrent: TEM 0 power supply current measured as -0.17A and within the required range of [-1.0, 5.0]

cal33V: TEM 0 CAL 3.3V digital measured as 3.36V and within the required range of [3.0, 3.5]

cal33V: TEM 0 CAL 3.3V analog measured as 3.38V and within the required range of [3.0, 3.5]

calBias: TEM 0 CAL bias V0 measured as 0.18V and within the required range of [0.0, 80.0]

calBias: TEM 0 CAL bias V1 measured as 25.77V and within the required range of [0.0, 80.0]

calBias: Warning: Conversion constant for LDET0CALBIASI was not in the database, using the data from the configuration file

calBias: TEM 0 CAL bias current measured as 0.01A and within the required range of [-1.0, 6.0]

calAfeeTemp: TEM 0 CAL AFEE 0 temperature 1 measured as 25.96C and within the required range of [23.0, 40.0]

calAfeeTemp: TEM 0 CAL AFEE 1 temperature 1 measured as 25.49C and within the required range of [23.0, 40.0]

calAfeeTemp: TEM 0 CAL AFEE 2 temperature 1 measured as 26.06C and within the required range of [23.0, 40.0]

calAfeeTemp: TEM 0 CAL AFEE 3 temperature 1 measured as 25.19C and within the required range of [23.0, 40.0]

readDaqFeedCurrent: Read the DAQ feed current as 0.59A

Power Off CAL 0

cal33V: TEM 0 CAL 3.3V digital measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

cal33V: TEM 0 CAL 3.3V analog measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

Power On TKR 0

daqFeedVoltage: DAQ feed voltage 28.12V is within [27.0, 29.0]

readDaqFeedCurrent: Read the DAQ feed current as 0.24A

temPsTemp: PDU 1 TEM 0 power supply temperature measured as 19.42C and within the required range of [-30.0, 45.0]

tkrTemp: TEM 0 TKR cable 0 temperature 0 measured as 25.46C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 0 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 1 temperature 0 measured as 25.66C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 1 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 2 temperature 0 measured as 24.96C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 2 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 3 temperature 0 measured as 27.03C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 3 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 4 temperature 0 measured as 25.32C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 4 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 5 temperature 0 measured as 26.40C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 5 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 6 temperature 0 measured as 24.80C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 6 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 7 temperature 0 measured as 25.52C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 7 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

daqFeedVoltage: DAQ feed voltage 27.73V is within [27.0, 29.0]

daqCurrentDelta: DAQ feed current delta 0.54A is within [-1.0, 1.0]

temPsCurrent: Warning: Conversion constant for LDET0TEM28I was not in the database, using the data from the configuration file

temPsCurrent: TEM 0 power supply current measured as 0.08A and within the required range of [-1.0, 5.0]

tkrVoltage: TEM 0 TKR 1.5V analog measured as 1.44V and within the required range of [0.0, 2.0]

tkrVoltage: TEM 0 TKR 2.5V digital measured as 2.53V and within the required range of [0.0, 3.0]

tkrVoltage: TEM 0 TKR 2.5V analog measured as 2.57V and within the required range of [0.0, 3.0]

tkrBias: TEM 0 TKR bias V0 measured as 0.25V and within the required range of [0.0, 100.0]

tkrBias: TEM 0 TKR bias V1 measured as 26.02V and within the required range of [0.0, 100.0]

tkrBias: Warning: Conversion constant for LDET0TKRBIASI was not in the database, using the data from the configuration file

tkrBias: TEM 0 TKR bias current measured as -0.00A and within the required range of [-1.0, 10.0]

tkrTemp: TEM 0 TKR cable 0 temperature 0 measured as 25.46C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 0 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 1 temperature 0 measured as 25.69C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 1 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 2 temperature 0 measured as 24.96C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 2 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 3 temperature 0 measured as 27.06C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 3 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 4 temperature 0 measured as 25.32C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 4 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 5 temperature 0 measured as 26.44C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 5 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 6 temperature 0 measured as 24.80C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 6 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 7 temperature 0 measured as 25.69C and within the required range of [-123.0, 40.0]

tkrTemp: TEM 0 TKR cable 7 temperature 1 measured as -114.72C and within the required range of [-123.0, 40.0]

readDaqFeedCurrent: Read the DAQ feed current as 0.78A

Power Off TKR 0

stopTkrPrompt: Warning: Unhandled test: stopTkrPrompt in powerOffTkr Action

tkrVoltage: TEM 0 TKR 1.5V analog measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

tkrVoltage: TEM 0 TKR 2.5V digital measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

tkrVoltage: TEM 0 TKR 2.5V analog measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

Power Off TEM 0

stopTemPrompt: Warning: Unhandled test: stopTemPrompt in powerOffTem Action

temVoltage: TEM 0 3.3V voltage measured as 1.14V and within the required range of [0.0, 2.0]

Power On AEM

gasuVoltages: AEM/EBM 3.3V voltage 3.28V is within [3.0, 3.6000000000000001]

gasuVoltages: AEM/EBM 2.5V voltage 2.50V is within [2.0, 2.6000000000000001]

gasuVoltages: AEM/EBM 3.3V voltage 3.30V is within [3.0, 3.6000000000000001]

gasuVoltages: AEM/EBM 2.5V voltage 2.51V is within [2.0, 2.6000000000000001]

freeBoardVoltage: AEM free board 0 voltage measured as 0.00V and within the required range of [0.0, 0.10000000000000001]

freeBoardCurrentDelta: Warning: Can not find a previous free board current measurement, caching it now...

freeBoardCurrentDelta: Read the free board current as 0.00A

freeBoardCurrentDelta: Free board current delta 0.00A is within [0.0, 0.90000000000000002]

freeBoardTemp: AEM free board 0 temperature measured as -114.72C and within the required range of [-120.0, 30.0]

Power On ACD free board 0

gasuVoltages: AEM/EBM 3.3V voltage 3.35V is within [3.0, 3.6000000000000001]

gasuVoltages: AEM/EBM 2.5V voltage 2.46V is within [2.0, 2.6000000000000001]

gasuVoltages: AEM/EBM 3.3V voltage 3.28V is within [3.0, 3.6000000000000001]

gasuVoltages: AEM/EBM 2.5V voltage 2.46V is within [2.0, 2.6000000000000001]

freeBoardVoltage: AEM free board 0 voltage measured as 3.71V and within the required range of [3.0, 3.7999999999999998]

freeBoardCurrentDelta: Free board current delta 0.00A is within [0.0, 0.90000000000000002]

freeBoardTemp: AEM free board 0 temperature measured as -114.72C and within the required range of [-120.0, 30.0]

Power Off ACD Free Board 0

gasuVoltages: AEM/EBM 3.3V voltage 3.36V is within [3.0, 3.6000000000000001]

gasuVoltages: AEM/EBM 2.5V voltage 2.53V is within [2.0, 2.6000000000000001]

freeBoardVoltage: AEM free board 0 voltage measured as 0.00V and within the required range of [-0.10000000000000001, 0.80000000000000004]

Power Off AEM

freeBoardVoltage: AEM free board 0 voltage measured as 0.00V and within the required range of [-0.10000000000000001, 0.80000000000000004]

Power Off GASU and PDU