Thinks this would help diagnose/solve a lot of problems
Automate SSA drive level max
Get rid of lower bound failure
Lauren suggested a post-mortem for the helium oscillation that looked like PRL noise
Would be an interesting case study to share during the downtime
Janice says ops are thinking about how to better communicate cavity instabilities causing beam instabilities, how to track down cavity instabilities, etc.
Should show up as AOTs, but ops aren’t seeing that
Check the hierarchy there
POTs can be both be reactive and mask other problems on the cavity display
Sebastian suggests looking at the amplitudes
PRL, PJT, and FBS are higher than AOT and POT
PFB is below AOT and POT
Make a display with the “four resistor boxes” alone?
Look at the rate of change of the fault counters?
Other downtime prep
STCAV0 installation will need valves closed
Turn off water-cooled magnets (make sure it’s on the downtime script)
LO tightening work will need followup calibration
Turn off all the superconducting magnets before 4K, but after we care about dark current
Close vacuum valves in non-particle free areas
Check work in particle-free area to see if we need valves closed
Cavities that keep getting turned off for UH/DH: CM27-2, CM33-2, CM34-2?
Turn down gradients?
Try active resonance control?
Make time to study active resonance control
Jorge is very interested in this
Try on CM07-2, CM19-1 and -2 first
SC recovery scheduled for January 16th, after the weekend after STCAV0 installation is scheduled to finish