Ops communication highlightsAll
  • Make sure to clarify to ops when they should pass information on to different shifts to avoid unnecessary calls
    • Ask them to make logbook entries
  • Common problems communication: AOSD 3 pm Thurs meeting?  Confluence?
  • Discussed having ops regularly check for red boxes
  • Get ops in the habit of checking out the SSA expert panels just informationally?
      • Might be confusing due to HL ganging issues/generally scary

Recent cavity measurements 
  • Different manufacturers have different cavities with different flux expulsions due to Nb supplier differences
  • Have a problem resolving Q's above 4e10 - 2W of power resolution is very challenging
  • How much can we resolve different heater powers?
  • Probably can't trust a calibration more than 24 hrs old

Schedule 
  • Nicole and Ryan to run up cavities together tomorrow
    • Nicole will take notes on the flow charts during run up
  • Will need to come in on swing shift 6/11 (Sunday) to do cavity detunes before June downtime
  • Email Dan if there's a time we can't be on-call in the next few weeks

SSA's/CoHE/Fans?
  • Request: drain voltage setup to nominal isn't automatic.  Can it be?
    • Andy: should be something Mike Dunning can take care of
  • 'Fan ritual' for HLs is a pain
    • Don't have even have SW from R&K to deal with it at the moment
  • 10-6 SSA tripping off frequently - SSP error
    • CoHE problem, will be dealt with eventually (CATERed)
  • Andy would like help looking at cavity scale parameters alarm for <25 MV (or was it 20?) and >50 MV
    • Some are quite low, need an attenuator

Misc Updates
  • Fudge factor - separate meeting
  • Decarads to be moved in June downtime
  • Briant has a job to look at the magnets in CM22
  • An Le is working on STDZ and degauss errors today
  • Rolling out phase offset drift test to CM32
  • Detune frequency drift test will take longer to roll out - no software fix yet

Action items

  • Make sure ops knows where the 'Things to Try' sheet is
  •  Take notes on start up flow charts
  • Email Dan if you have a on-call confilct
  •