Reason for change
We have a new release of GlastRelease that includes all the new (filter) configuration information i.e. getting the Moot key, extracting the correct filter information (DGN prescales for example) and automatically configuring and running the correct filters in Gleam. This GR also has the real FSW filter bits in the Merit ntuple.
This GR has a known problem: The Gleam HIP fillter passes (actually, leaks) all events. It's possible that the Gleam MIP filter suffers from a smaller degree of the same problem.
There are updates to the SVAC ntuple and the monitoring to adapt to this new GR.
Test Procedure
We have processed real data and MC on the DEV server with this version of L1Proc.
Note that there are no changes in the HalfPipe because of this GR. The relevant tables (Run Id - Moot key association) are being filled independently of L1 (and has been for some while).
Rollback procedure
L1Proc can be rolled back to the previous version. We also have the capability to use Job Options to disable Moot access.
CCB Jira
Details
L1Pipeline v1r56
-
GlastRelease v15r13:
- Includes (filter) configuration related changes.
- Systemtestsfor GR v15r13wrt GR v15r6p1 show no differences.
- RM diffwith respect to the previous production release, GR v15r6p1.
svac/Monitor: v1r2p1
- Change HFC for Hip and DFC for Dgn in MonInput_OBFStatus.cxx because of corresponding name changes in GR v15r8.
- Change getStatus32() by getStatusWord() to match with the new GLAST release (v15r8).
svac/EngineeringModelRoot: v4r1p4
- Changes induced by GR v15r8: Added the Moot key. Added filter prescale factors and indices for all the filters. Added some Gleam gamma-filter quantities and updated to new names of Gleam filters.
evtClassDefs: v0r5
- Updated for name changes in Gleam filters.
svac/TestReport: v6r9
- Changed the range for Datagram Histos so the complete distribution is included.
dataMonitoring/DigiReconCalMeritCfg: v1r1p32
- Remove quantity AcdVtxActiveDist. This addresses Jira GDQMQ-161.
- Change truncation from 1.1 mip to 2.5 mip in plots Recon_ReconAcdPhaMipsCorrectedAngle_PMTX_Zoom_TH1_AcdTile. This addresses Jira GDQMQ-162.
- New ACD rate asymmetry trending quantities. This addresses Jira GDQMQ-163.
dataMonitoring/Common: v3r1p6
- Now a pAlarm object is instantiated for each pAlarmSet object, even when the corresponding ROOT object cannot be found in the file. The corresponding output status is set to UNDEFINED and it appears in the summary. Usefull for debug to make sure we don't screw up thing when messing around with the variable names. Relevant jira(s): GDQMQ-159
ft2Util: v1r2p18
- Various bug fixes in interpolation.
Complete set of tags for L1Proc 1.56
Code Versions
GlastRelease (sim/recon) v15r13*
ScienceTools (Level 2) : v9r5p5
Science Ops (task defs, scripts):
Level 1 pipeline code and applications running in L1:
svac/L1Pipeline: v1r56*
calibTkrUtil v2r2p3
dataMonitoring/AlarmsCfg: v1r1p1
dataMonitoring/FastMonCfg: v1r2p0
dataMonitoring/DigiReconCalMeritCfg: v1r1p32*
dataMonitoring/Common: v3r1p6*
dataMonitoring/FastMon: v3r2p1
datMonitoring/IGRF: v1r0p1
svac/Monitor: v1r2p1*
svac/EngineeringModelRoot: v4r1p4*
svac/TestReport: v6r9*
users/richard/pipelineDatasets: v0r4
ft2Util: v1r2p18
evtClassDefs v0r5*
GPLtools: v1r10