Documentation and diagrams of subsystems
FACET-II Timing System ConfigurationÂ
Event Code | Name | Brief Description | Beam Code | Inclusion | Exclusion |
---|---|---|---|---|---|
201 | Inject | Controls rate of beam from gun | 10 | T5; MPS_POCKCELL | NO_GUN_PERM; BCS FAULT; T1,T2,T3,T4,T6 |
202 | Scavenger | Rate of beam to SCAV line | 10 | T5; MPS_POCKCELL | NO_GUN_PERM; BCS FAULT; FFTB_ext; T1,T2,T3,T4,T6 |
203 | FACET e- | Rate of beam to S20 | 10 | T5; FFTB_ext; MPS_POCKCELL | NO_GUN_PERM;BCS_FAULT;T1,T2,T3,T4,T6 |
211 | RF Accel | 30 Hz RF Acceleration | 10 | T5 | BCS_FAULT;T1,T2,T3,T4,T6 |
212 | RF Standby | 30 Hz RF Standby | 10 | T5 | T1,T2,T3,T4,T6 |
213 | Profile Mon | Deprecated (was used for UNIQ cameras) | |||
214 | PM DAQ | This EC controls cameras DAQ and mimics 201/203 | 10 | T5; MPS_POCKCELL | NO_GUN_PERM; BCS FAULT; T1,T2,T3,T4,T6 |
221 | CMOS Beam | Pre-trigger for CMOS cameras | 11 | T5; RATE_10HZ | T1,T2,T3,T4,T6 |
222 | GigE Beam | Redundant with 201? | 10 | T5; MPS_POCKCELL | NO_GUN_PERM; BCS FAULT; T1,T2,T3,T4,T6 |
223 | FACET TS5 10Hz | 10 Hz used with GigE or Laser | 10 | T5; TEN_HERTZ | T1,T2,T3,T4,T6 |
224 | FACET TS5 5Hz | 5 Hz used with GigE or Laser | 10 | T5; FIVE_HERTZ | T1,T2,T3,T4,T6 |
225 | FACET TS5 1Hz | 1 Hz used with GigE or Laser | 10 | T5; ONE_HERTZ | T1,T2,T3,T4,T6 |
226 | FACET TS5 0.5Hz | 0.5 Hz used with GigE or Laser | 10 | T5; HALF_HERTZ | T1,T2,T3,T4,T6 |