This page describes the relational databases and related systems of the LCLS controls environment. These are presently exclusively ORACLE.

Date of last (real) update: 2009.

Attachments and External References

  File Modified
Microsoft Excel Sheet Controls Data Sizing.xls Data Sizing planning spreadsheet (draft for illustration) Feb 11, 2009 by Greg White
Microsoft Word 97 Document database overview.doc Table of all controls "databases" current uses and plans Feb 11, 2009 by Greg White
JPEG File database overview.jpg Database schemas by network (simple view, distinguishing schema on dev and prod networks) Feb 11, 2009 by Greg White
JPEG File DatabasePopulation.jpg Input XAL files and the tables to which they contribute data, for the LCLS online model Apr 24, 2009 by Greg White
JPEG File database schemas and interfaces.jpg Database schemas by data interface (eg load script, JDBC etc) Feb 11, 2009 by Greg White
File Latest_Apex_400_Online_Model_From_SLACDEV.sql Online Model APEX application Jan 30, 2009 by egrunhau
PDF File lcls_elements_woodley_chgs.pdf Overall symbols and model database subschema Apr 24, 2009 by Greg White
PDF File MADtoDBProcessFlow.pdf Process of creating a MAD symbols, creating an XAL beamline description, running it, and uploading the results. Full model creation system. Apr 24, 2009 by Greg White
JPEG File MainDatabasesOfLCLS.jpg Judy's overview diagram of all "databases" in use in LCLS Apr 24, 2009 by Greg White
JPEG File ModelMan.jpg Screen snapshot of Model GUI Apr 24, 2009 by Greg White
JPEG File ModelSubschema.jpg The Online model sub-subschema of the overall model subschema Apr 24, 2009 by Greg White
JPEG File RunningProbeModel.jpg Inputs and outputs of running (aka "Probing") an XAL model Apr 24, 2009 by Greg White
JPEG File schemas_and_apps.jpg Database data network data flows Feb 11, 2009 by Greg White

External References

Controls -> Database Infrastructure in sharepoint.
Model Database Conceptual Requirements and Design in sharepoint

Current Database Applications and Schema

Control System Application

Critical to ops

Description

Input/Load

UI/Output

Dependencies

Users

Accelerator

Responsible person

Schema@Instance

 

LCLS Infrastructure

 

Multi-function database of LCLS devices and related data:

  • modelling deck
  • devices
  • polynomials
  • cabling data
  • laser device parameters
  • inventory, links to QA documents and drawings
  • web interface for IRMIS and Aida devices_and_attributes lists
  • APEX applications
    • excel spreadsheet upload
    • sql update (SQL Developer)
    • insert/updates apps
  • IRMIS devices_and_attributes list view
  • APEX query apps (for devices, etc.) with Excel spreadsheet export
  • Modelling app (Affects AIDA tables in schemas AIDADEV and AIDAPROD)

AIDA Tables
SID Tables
DRAW Tables
Database Links
Firewall Rules

Engineers
CAD Designers
Installation
Physicists
High Level Applicatons
Operators

LCLS

Andrea Chan, Elie Grunhaus

LCLS_INFRASTRUCTURE@
SLACPROD

LCLS_INFRASTRUCTURE@
SLACDEV

CAPTAR

 

Racks, crates, cabling database

  • Excel spreadsheet for initial upload
  • Data administrator uses Oracle Forms

web: cgi, asp, html

 

Engineers

LCLS
PEPII
NLCTA

Andrea Chan, Elie Grunhaus

CAPTAR@SLACPROD

CATER

 

Problem reporting and management application

APEX

APEX

 

Engineers
Physicists
Operators

LCLS
PEPII
NLCTA

Andrea Chan, et al

MCC_MAINT@SLACPROD

AIDA

x

"Accelerator Integrated Data Access"
accelerator data interactions (get, put, control operations)

shell and perl scripts/cron jobs run daily, and after DBINSTALL

  • matlab, bigtime
  • java applications (e.g. SCORE)
  • web: jsp
  • command line interface
  • all

Firewall Rules

Engineers
Physicists

LCLS
PEPII
NLCTA

Greg White, Bob Hall

AIDAPROD@
SLACPROD
AIDADEV@
SLACPROD

IRMIS

x

EPICS database configuration data:

  • list of IOCs
  • IOC configuration data
  • list of PVs and configured fields
  • list of PVs by PV client

perl crawler scripts/cron jobs run daily

  • java
  • web: jsp (now in development)
  • APEX query page (from LCLS Infrastructure app)
  • ad hoc queries (TOAD)
  • AIDA query scripts
  • pvlist query script
  • LCLS Infrastructure queries

Firewall Rules

AIDA
pvlist
Operators
Engineers

LCLS
PEPII
NLCTA

Judy Rock

IRMISDB@
SLACPROD

IRMISDB@
SLACDEV

e-log:

  • ELOG_OWNER
  • ELOG_READER
  • ELOG_WRITER
  • PVLOGGER

x

logging for accelerator operations

  • web: php
  • tcl/tk application
  • unix watchdog
  • control system applications
  • web: php
  • tcl/tk application

 

Operations
Engineers
Physicists

LCLS
PEPII
NLCTA

Bob Hall

ELOG_OWNER@MCCO
ELOG_READER@MCCO
ELOG_WRITER@MCCO

PVLOGGER@SLACDEV

SCORE

x

save/restore ("configs") for accelerator operation setpoints and readbacks

  • SCORE java application
  • APEX application:
  • excel spreadsheet upload
  • SCORE java application
  • APEX query application
  • shell scripts for deleting data

 

Operations
Engineers
Physicists

LCLS

Debbie Rogind (UI),
Elie Grunhaus, Judy Rock (DB)

SCORE@MCCO
SCORE@SLACDEV

History Buffers wildcard PV select feature: pvlist table**

x

displays SLC history for selected signals. Signal selection can be done using wildcard characters in names, which are matched in the Oracle DB.

pv list load is ultimately from the IRMIS database

SCP

 

Operators
Physicists

NLCTA

Terri Lahey (DB), Judy Rock (load jobs)

DEMODB VMS

Button macro database

x

stores SCP button macros

SCP

SCP

 

Operators
Physicists

PEPII
NLCTA
LCLS

Terri Lahey

MCCDB

pvlists databases owned by Oracle users

  • nlcdev
  • nlcprod
  • pvudb
  • cd
    these could probably be eliminated, with some work

x

Databases of PV names assembled from IRMIS and PEPII-specific ascii file sources:

  • nlcprod.pmu_list is used for the Artemis pmu selection lists.
  • pvudb.pvu_rec contains PV names used as for AIDA batch load.

load scripts

  • AIDA update scripts
  • Remedy snapshot for Artemis

 

AIDA scripts

PEPII
NLCTA
LCLS

Judy Rock

NLCDEV@SLACPROD
NLCPROD@SLACPROD
PVUDB@SLACPROD
CD@SLACPROD

NLCDEV@SLACDEV
NLCPROD@SLACDEV
PVUDB@SLACDEV
CD@SLACDEV

BPM Orbit Display

x

BPM Orbit Display

Java application

Java application

 

Operators
Engineers
Physicists

LCLS

Mike Zelazny

MACHINE_MODEL@SLACPROD

Model DB

x

MAD and Online model data
ERD

Java application

Java application

LcLs Tables
AIDA Tables
Database Links
Firewall Rules

Operators
Engineers
Physicists

LCLS

Paul Chu

MACHINE_MODEL@
SLACPROD

Future plans

Timeframe

Application

footnote (below)

Uses Model data

Descr.

Input/Load

UI/Output

Users

Accelerator

Responsible person

Instance

Longer Term

Save/restore phase II

 

 

implement phase II, with features as listed in the Save/Restore specs doc

see above - existing app

see above - existing app

see above - existing app

see above - existing app

Debbie Rogind, Greg White

see above - existing app

?

Message Log
(Ron MacKenzie)

1

 

 

Applications:

  • channel watcher
  • IOCs
  • alarm handler
  • SCP messages
  • java programs (using ERR)

APEX application
jcmlog UI

Operations
Engineers
Multiple applications

LCLS
PEPII
NLCTA

?

MCCO

Short/Long Term

LCLS Infrastructure

 

 

Enhance for XAL

see above - existing app, and additional apps below

see above - existing app, and additional apps below

see above - existing app, and additional apps below

see above - existing app, and additional apps below

Andrea Chan, Elie Grunhaus

see above - existing app, and additional apps below

Shortterm

CAPTAR

 

 

 

 

 

 

 

Andrea Chan, Elie Grunhaus

 

Feb, 2008
there are 2 more stages

MPS

 

 

"... a relational database for MPS so that both generation of code and queries can be derived from this master list."

APEX App

APEX App

Engineers

LCLS

Stephen Norum, Andrea Chan, Elie Grunhaus

SLACPROD
SLACDEV

Shortterm

Modelling

 

 

1. Model beamline and section definitions. An accelerator "section" is a part of the machine like the "injector spectrometer excursion" and is delineated by two so called "marker"
points. (DGRP and beamline)
2. Model twiss and Rmat. The results of model runs, for at least the extant and design machine, will be put into the database. A model db access API must be developed. (done)

?

Model DB Access API

Physicists

LCLS

Paul

MCCO

Longterm

Emittance

 

 

see * below

  • M&A: For instance which wires are in included in an emittance setup
  • Configs: Canned M&A setups.
  • Results: Emittance calculation results

?

?

Physicists

LCLS

Debbie Rogind

MCCO

Longterm

Profile Monitor

 

 

  • M&A: PVs used. sigma matrix, monitor screen coords and offsets etc
  • Configs: Canned M&A setups.
  • Results: profile images, fitting constants and fit results

?

?

Physicists
Engineers
Operations

LCLS

Mike Zelazny, Sergei Chevtsov

MCCO

Longterm

Wire Scans

 

 

  • M&A: normalization coeffs. PVs used. Z of wire. X,Y w.r.t BPM. Rate limit for wires.
  • Configs: Canned M&A setups.
  • Results: Calculated params (skew, ellipsoid axes), angular divergence etc.

?

?

Physicists
Engineers
Operations

LCLS

Sheng Peng

MCCO

Longterm

Orbit Correction

 

 

  • Configs: Canned "power steering" setups.
  • M&A: bpm weights, offsets, whether each bpm/corrector should be in the fit minimization.
  • Results: Probably no need to store results.

?

?

Physicists
Engineers
Operations

LCLS

HLA group

MCCO

Longterm

Orbit Applications

 

 

  • Configs: "Display groups" (should this be different to sections)?
  • M&A: Bpm offsets and corrections. Things that on SLC we would have called "STAT" bits (is there anything that its sensible to put in here as opposed to EPICS?)
  • Results: Orbit fitting coefficients?

?

?

Physicists
Engineers
Operations

LCLS

HLA group

MCCO

unlikely - holdover from VMS system

BPM Sampler

 

 

Do we want a similar facility for LCLS. Is this a generalization of PV Logger?

?

?

Physicists
Engineers
Operations

LCLS

HLA group

MCCO

Longterm

LEM

 

 

  • Config: LEM Group Definitions (set of model sections)
  • M&A: LEM options, model section used. For each section; beam-code, z range
  • Results: energy fudge factors.
  • will use the SCORE schema

?

?

Physicists
Engineers
Operations

LCLS

HLA group

MCCO

Longterm

Multiknobs and bumps

 

 

  • Configs: For each multiknob; "gain" coefficient, "turns" etc.
  • Devices in the multiknob
  • M&A: None
  • Results: none

?

?

Physicists
Engineers
Operations

LCLS

HLA group

MCCO

Longterm

Feedback

 

 

  • feedback name
  • feedback rate
  • matrices: 2 per feedback (these are variable size arrays by the way)
  • matrix function name: 2 per feedback
  • some other scalar parameters, depending on the matrix calculation used by the feedback
  • feedback algorithm name: per feedback
  • Several lists of PV Names per feedback, grouped into Actuators, Measurements, States, StateSetpoints, Check PVs, Storage PVs, Control PVs
  • weighting values per measurement device per feedback
  • reference orbit, per feedback

?

?

Physicists
Engineers
Operations

LCLS

Diane Fairley

MCCO

May be shortterm

Start to End simulation

1

 

Predict FEL power

?

?

Physicists
Engineers
Operations

LCLS

HLA group

MCCO

Longterm

Button macro functions as saved scripts

 

 

 

?

?

Operations

LCLS

HLA group

MCCO

Longterm

Correlation Plots

 

 

 

java

java

Operations
Engineers
Physicists

LCLS

HLA Group

MCCO

Longterm

Matching

 

 

 

java

java

Operations
Engineers
Physicists

LCLS

HLA Group

MCCO

Longterm

Photon Applications

 

 

Applications to support the photon beam and its interaction with the electron beam

?

?

Operations
Engineers
Physicists

LCLS

?

?

Longterm

Electron system data to be shared with the photon system

 

 

Shared data (and api's?)

?

?

Operations
Engineers
Physicists

LCLS

?

?


Footnotes:

  1. Predicted to produce large amounts of data.


Elements of HLA applications listed above:

  • M&A = "Measurement", "Analysis" (M&A)
  • "Configs" = stored sets of M&A setups, that can be configured and recalled interactively.
  • Results


Issues to address:

  • Need some mechanism for flagging large changes in production data that can affect (or break) existing applications.

 

Database Instance Hosts and Locations

Instance

Host

Location

SLACDEV

slac-oracle02

SCCS

SLACPROD

slac-oracle03

SCCS

MCCO

mccora2

MCC

MCCDB

mcc

MCC

DEMODB

mccdev

MCC

ORAP

?

SCCS  

  • No labels