EngineeringModel v5r070305p4:
TkrRecon v10r8p1gr0:
AcdUtil v0r2p4:
AcdRecon v2r0p5:
System tests:
Single tower MC has no change, all multitower MC using real calibrations have the CAL LO problem. MC using ideal calibration have no change. No change for data runs except for six tower data that has a few changes in TKR quanitites. This is due to using a different dead strip file (Johann corrected the mistake he made in the calibration database last week). When he made the mistake I saw changes in the same quantities.
It looks like it's the TholdCI - which only affects simulation (only CAL LO in TriggerAlg). I think it's only the calib file that needs to be fixed (external to this release). The same code with a preship TholdCI file was ok.
and:
svac/EngineeringModelRoot v1r12:
Verified by Anders et al.
v1.4
glast-ground v0r3p7
grits-gino-web version 0.55 (v0r5p5)
grits-gino version 0.95 (v0r9p5)
grits-gino-xml version 1.42 (v1r4p2)
grits-common version 0.32 (v0r3p2)
online: v2r3p2 (SVAC code moved to AFS)
code/tasks v3r4p5
pipelineDatasets v0r3
v0r5p0
eLog: v2r2p8 (Moved code to AFS)
ConfigTables: v3r2p0 (Added ACD information)
TestReport: v3r4p9 (digi & recon reports)
EngineeringModelRoot: v1r12 (SVAC tuple) **changed**
Approved: unanimous 24 Jan 2006