Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migrated to Confluence 4.0

...

sid02

This is the version of the Silicon Detector modelled for the Letter of Intent (LOI) exercise.
The compact description of this detector in xml format can be found at http://www.lcsim.org/detectors/sid02.zipImage Removed.

What follows is a plain text description of the file compact.xml found in this zip file.

...

The beampipe consists of a cylindrical central tube and forward/backward conical sections.  The 0.040cm thick Beryllium central tube has an inner radius of 1.2cm and extends to |z|<6.25cm. The conical sections have a cone half-angle of 43.4mrad with an inner radius that flares from 1.2 cm at 6.25cm to 8.218cm at |z|=167.9cm. The conical sections are 0.0875Cm 0875cm thick Be for 6.25cm<|z|<37.5cm, where they transition to steel. The thickness of the steel section flares from 0.0875cm at |z|=37.5cm to 0.1992cm at |z|=167.9cm. A titanium liner on the inner surface of the beam pipe consists of a 0.0025cm thick cylinder and 0.0075cm thick conical sections.

...

Layer

Inner Radius

Outer Radius

|z|

1

2.78cm

16.67cm

20.40 40cm

2

7.51cm

16.67cm

53.85cm

3

11.65cm

16.67cm

82.95cm

...

Material

Thickness

Silicon (active)

0.002cm

Silicon (dead)

0.028cm cm

Carbon Fiber (25%)

0.026cm

Calorimeters:

Electromagnetic Calorimeter:

An x-y quarter view of the sid02 tracking detectors can be found at sid02_Tracker_QuarterView.eps
A plot of the material, expressed in percentage of a radiation length (X/X 0 ), as a function of the polar angle, can be found at sid02TrackerMaterialScan.eps

Calorimeters:

Electromagnetic Calorimeter:

This element sets the basic size and aspect ratio for the rest of the detector. The inner radius for the This element sets the basic size and aspect ratio for the rest of the detector. The inner radius for the barrel is 127cm. The aspect ratio is set to cos(theta)=0.8, meaning the inner z of the endcap EM calorimeter is at z of 168cm.

...

material

thickness

Tungsten

.250cm

G10 Silicon

.068cm 032cm

Copper

.005cm

Kapton Silicon

.032cm 030cm

Air

.025cm 033cm

followed by ten layers of

material

thickness

Tungsten

.50cm

Silicon

.032cm

Copper G10

.068cm 005cm

Silicon Kapton

.032cm 030cm

Air

.025cm 033cm

There is a sensitive silicon layer before the first layer of Tungsten to provide additional electron/photon discrimination, giving a total of 31 layers of silicon readout.
The Tungsten alloy being used is TungstenDen24 (93% W, 6.1% Ni, .9% Fe) with a density of 17.8 g/cm 3 .
The endcap plug sits inside the barrel cylinder, so the barrel z extent is The endcap plug sits inside the barrel cylinder, so the barrel z extent is +/- 182.0cm.
The endcap starts at an inner radius of 26cm 20cm and extends out to 126.5cm.

Segmentation

The readout is 3.5mm x 3.5mm square cells.

Hadron calorimeter:

The hadron calorimeter is a sampling calorimeter composed of 34 40 layers of

material

thickness

Steel

2.0cm

G10

0.3cm

PyrexGlass

0.11cm

RPCGas

0.12cm

PyrexGlass

0.11cm

G10

0.3cm

Air

0.16cm

It begins immediately outside of the EM calorimeters, with the endcap plug sitting inside the barrel.

The barrel inner radius is 141.0 with a z extent of +/- 277294cm.2cm.
The endcap extends from an inner radius of 2620.0 cm 0cm to an outer radius of 140.75, inner z of 182.0.

Segmentation

The readout is 1cm x 1cm squares.

Solenoid:

The solenoid is modelled as a cylinder with an inner radius of 250cm255cm. This is larger than the outer radius of the hadron calorimeter since we will not be building a cylindrical detector, but a polygonal one (current thinking is octagonaldodecagonal). The barrel composition is as follows:

...

This is capped with disk endplates of 6cm steel from r=250cm to 332.8cm

The field is solenoidal, constant 5 Tesla along z up to half the coil thickness and -0.6 outside.

Muon System:

The muon system is implemented as a sampling calorimeter composed of 48 11 layers of :

material

thickness

Iron

5.0cm

G10

0.3cm

PyrexGlass

0.11cm

RPCGas

0.12cm

PyrexGlass

0.11cm

Air

0.86cm

20cm thick Iron plates interspersed with double RPC readout.
The barrel inner radius is 333338.0cm 8cm with z extent of +/- 277cm294cm.
The endcap sits outside the barrel at an inner z of 277303.5cm 3cm and radius from 2620.0cm to 645608.0cm

The field is solenoidal, constant 5 Tesla along z up to half the coil thickness and -0.6 outside.

2cm

Segmentation

The readout is 3cm x 3cm squares.

An x-y quarter view of the sid02 calorimeters and solenoid can be found at sid02_Calorimeters_QuarterView.eps

Masks and Far Forward Detectors

This detector The far forward region is designed for the 2mr 14mr beam crossing solution . so has separate incoming (inner radius 1.0cm) and outgoing (inner radius 1.5cm) beampipes. The far forward plug extends out to
is designed to fit within a radius of 25cm20cm. It starts with an electromagnetic calorimeter (LumiCal) with the same composition as the
endcap calorimeter, extending from 86.68cm 0cm out to 25cm19.5cm.

The calorimeter is backed up by a conically tapered tungsten mask, inner radius 8.68 0cm at z of 182cm,
tapering to 16cm at z of 330cm313.5cm. The outer radius is constant at 25cm15.5cm.

There is a far forward low-Z shield (10cm thick Beryllium12.39cm thick Borated polyethylene) at z of 285cm, with a 1.5 cm central aperture.282cm.

This is followed by a 50 layer silicon-tungsten calorimeter (BeamCal)at z of 295cm, with a single aperture for
both the incoming and outgoing beams, radius 2cm.

Segmentation

All the far forward electromagnetic calorimeters have 3.5mm x 3.5 mm square readout.

An x-y quarter view of the sid02 far forward region (also referred to as the machine-detector interface, or MDI) can be found at sid02_MDI_Cut.eps

For additional details, please see the xml file.