Reasons for Change
- Move to ST v9r15p5 from ST v9r15p4
- New version of ASP/BayesianBlocks v2
- Handle empty ROIs that arise from increased rocking angle for six_hour intervals in DRP_monitoring task.
- Use later versions of asp_pointlike, asp_skymaps, asp_healpix packages that were modified for SCons builds
- Rename package-specific clean_up_files.py scripts since SCons builds somehow cannot deploy into python subdirectories.
Test Procedure
Tested in dev on data in /ASP/TestSims2.
Rollback Procedure
Revert to ASP v3r0p3 and ST v9r15p4.
CCB Jira
Details
- ASP v3r1p0
- AspHealPix v0r0p3
- AspLauncher v1r4p0
- AspPolicy v0r6p1
- BayesianBlocks v2r0p0*
- Revised interface to allow for ncp_prior to be specified when light_curve method is called rather than in the constructor
- asp_pgwave v1r10p2*
- In getPgwInputData.py, refactor logic to select appropriate EVENT_CLASS cuts for test data vs flight data
- clean_up_files.py -> asp_pgwave_clean_up_files.py
- modify PGWave.xml to use asp_pgwave_clean_up_files.sh (new xml task def)
- drpMonitoring v1r7p5*
- Test each ROI in assignRois.py to ensure events remain after standard gtselect and gtmktime filtering is applied.
- clean_up_files.py -> drp_clean_up_files.py
- modify DRP_monitoring.xml to use drp_clean_up_files.py (new xml task def)
- grbASP v4r8p6*
- use new BayesianBlocks interface
- add autoRetryMaxAttempts to GRB_blind_search blind_search process (new xml task def)
- clean_up_files.py -> grbASP_clean_up_files.py
- modify GRB_afterglow.xml to use grbASP_clean_up_files.py (new xml task def)
- pyASP v3r6p2*
- add pipelineServer() function so that clients can easily determine whether the code is run in 'PROD' or 'DEV'
- asp_healpix v2r2p3*
- asp_skymaps v1r13p2*
- asp_pointlike v6r14p1*