Request to update alarm settings in L1Proc 1.79

Reason for change

The new version (AlarmsCfg-05-20-03, as opposed to AlarmsCfg-05-20-01) includes a modification to accommodate the new LAT configuration in which the TEM diagnostics is enabled by default.

Test Procedure

We have processed monitoring products from real on-orbit data (LPA) locally with this version of AlarmsCfg.

Rollback procedure

The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.

CCB Jira

SSC-233@JIRA

Details (release notes for dataMonitoring/AlarmCfg for AlarmsCfg-05-20-03)

AlarmsCfg-05-20-03 16-Oct-2009 lbaldini Changed limits on the uncompressed/compressed event size)

  • Limits on digi_trend OutF_Ratio_EvtSize_CompressedEvtSize changed after the enabling of the diagnostics.

Labels

sassoccb sassoccb Delete