Reason for change
The new version (v5r17p4, as opposed to v5r16p2) introduces a few minor limit changes and protections against low statistics detailed below.
Test Procedure
We have processed monitoring products from real on-orbit data (LPA) locally with this version of AlarmsCfg.
Rollback procedure
The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.
CCB Jira
Details (release notes for dataMonitoring/AlarmCfg for v5r17p4)
v5r17p4
Quite a few alarms protected against low statistics.
- Digi eor:
- AcdVetoMap_TH1 (x_rms): added condition on minimum number of entries (100000).
- Acd_GemVeto_AcdTile_TH1 (x_rms): added condition on minimum number of entries (100000).
- CondArrCNO_CalLoOpensWindow_TH1 (x_rms): added condition on minimum number of entries (100).
- CondArrCNO_TKROpensWindow_TH1 (x_rms): added condition on minimum number of entries (200).
- TkrHits_TH1_Tower_* (x_average): added condition on minimum number of entries (10000).
- CondSummaryWord_TH1 (reference_histogram): added condition on minimum number of entries (10000).
- CondArrCalLo_TKROpensWindow_TH1 (reference_histogram): added condition on minimum number of entries (5000).
- CondArrTKR_CalLoOpensWindow_TH1 (reference_histogram): added condition on minimum number of entries (1000).
- FastMon eor:
- CondArrCalLo_TKROpensWindow_TH1 (reference_histogram): added condition on minimum number of entries (5000).
- CondArrTKR_CalLoOpensWindow_TH1 (reference_histogram): added condition on minimum number of entries (1000).
- CondSummaryWord_TH1 (reference_histogram): added condition on minimum number of entries (10000).
- CondArrCNO_CalLoOpensWindow_TH1 (x_rms): added condition on minimum number of entries (100).
- CondArrCNO_TKROpensWindow_TH1 (x_rms): added condition on minimum number of entries (200).
v5r17p3
- Alarm limits changed for CondArrCNO_CalLoOpensWindow_TH1 in both digi and fastmon eor.
- warning max: 0.0006 -> 0.0008
- error max : 0.0010 -> 0.0015
v5r17p2
- Condition on the minimum number of entries changed from 10 to 15 in CondArrCalHi_CNOOpensWindow_TH1 for the alarms on the average and the rms of the distribution.
v5r17p1
- Warning high limit on CondSummaryWord_TH1 (reference histogram) for both digi end of run and fastmon end of run changed from 100 to 110 (see http://www-glast.stanford.edu/protected/mail/datamon/2892.html)
v5r17p0
- Warning upper limit for OutF_Ratio_EvtSize_CompressedEvtSize in digi_trend changed from 3.2 to 3.25.