Request to update alarm settings in L1Proc 1.73 (round 4)

Reason for change

The new version (v5r16p2, as opposed to v5r15p1) takes care of a new noisy cal channel (1160) and features a few new alarms on the filter rates, compression level and bandwith usage. See below for details.

Test Procedure

We have processed monitoring products from real on-orbit data (LPA) locally with this version of AlarmsCfg.

Rollback procedure

The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.

CCB Jira

SSC-209@JIRA

Details (release notes for dataMonitoring/AlarmCfg for v5r16p2)

v5r16p2

  • Added alarms on the compression level and bandwidth in the digi trending. Precisely, alarms have been added on the following quantities:
    • Time::Mean_CompressionLevel
    • Time::Rate_CompressedEvtSizeInBytes
    • Time::Mean_CompressedEvtSizeBytes
  • Relevant jira(s): GDQMQ-313

v5r16p1

  • Added alarms on the filter rates in the digi trending:
    • Time::Rate_FswFilters_DGN
    • Time::Rate_FswFilters_HIP
    • Time::Rate_FswFilters_GAMMA
      This is essentially to make sure that all the filters are correctly running in the nominal science configuration.
  • Relevant jira(s): GDQMQ-312

v5r16p0

  • Alarm limits (warning max and error max) changed in calpeds_eor for channel 1160 for the ""y_values" alarms on:
    • CalXAdcPedRMS_LEX1_TH1 (1.2, 1.8 -> 3.6, 3.6) and
    • CalXAdcPedRMS_LEX8_TH1 (10.0, 15.0 -> 30.0, 30.0)
  • Relevant jira(s): GDQMQ-314