Design 1:
DB
Xml Schema
file-transfer.rnc
Source:
Pre-Req:
Perl:
- Module::Load
- HTTP::Daemon
- XML::SAX
- Config::General
- aliased
- Readonly
- Term::ReadKey
- DBI::DBD
- DBD::mysql
- DBD::SQLite
- Class::Accessor
- Class::Fields
- Params::Validate
- Statistics::Descriptive
- Data::UUID
- IO::Interface
- DateTime
- Error
- Log::Dispatch::FileRotate
- Log::Log4perl
Configuration:
max_worker_lifetime 60
max_worker_processes 30
disable_echo 0
ls_registration_interval 60
ls_instance http://192.168.117.129:9995/perfSONAR_PS/services/hLS
root_hints_url http://www.perfsonar.net/gls.root.hints
<port 9000>
<endpoint /perfSONAR_PS/services/FT/MA>
service_type MA
module perfSONAR_PS::Services::MA::FT
<ftma>
service_description FT MA
service_accesspoint http://localhost:9000/perfSONAR_PS/services/FT/MA
enable_registration 0
service_name perfSONAR_PS FT MA
ls_registration_interval 60
service_timeout 60
query_size_limit 100000
db_host <database host>
db_username <database user>
db_name <database name>
db_password <database password>
db_type <database type>
</ftma>
</endpoint>
</port>
Installation:
- tar -xvf FileTransfer_MA.1b.tar
- mkdir /var/log/perfsonar
- Run the SQL Procedure(mysql) on the netlogger database to produce a secondary database. This secondary database is the one, the FTMA service will be interacting with.
How to run the Service:
- cd bin
- sh FtpMaExecute.sh --skip-input || --help
-
- Attempts to install the missing, perl modules.
- Stops any previous running instance of the service.
- Creates a backup of any existing log file.
- Everytime the script executes, it copies the log file from the main log directory to an hourlyfolder in the same directory. The folder is named as: Ftp_MM-DD-YY:HH
- Starts a new Instance of the service by running daemon.pl
Client Application:
The service includes a client tool to do some preliminary testing. This tool is present inside the bin dir as well.
- cd bin
- perl FTP_client.pl
- This simple execution will fetch all the metadata from the service, and provide the user with a final output showing all the metadata keys mapped on source and destination ip addresses.
- perl FTP_client.pl --help
-d Switch to debug level
--debug Same as -d
--url Url to the MA Service(FT)
default is localhost
--data Output Data as well
--src source ip (string)
--dst destination ip (string)
--SrcPath metadata param: Source file path(string)
--DestPath metadata param: Destination file path(string)
--stripes metadata param: number of stripes
--buffer metadata param: bufer size
--block metadata param: block size
--streams metadata param: number of streams
--program metadata param: program used for file transfer
--user metadata param: user, who requested the file transfer
--initEpochTime initial Time limit in Epoch (integer)
--finalEpochTime Final Time limit in Epoch (integer)
--initUtcTime initial Time limit in UTC (string)
--finalUtcTime final Time limit in UTC (string)
-h Print this help
--help Same as -h
- perl FTP_client.pl -d --data --DestPath=/ --stripes=1 --src=192.168.117.128 --dst=131.225.107.12 --initEpochTime=1220000000 --finalEpochTime=1225408002
-
- This execution will fetch metadata where destination path, stripes, source ip address and destination ip address is defined by the parameters passed.
- The --data argument makes sure that the returned metadata is then used to fetch data with start time and end time within the given limitation.
- The -d argument provides the debug data as well.