This page documents the installation experience of PerfSONAR at SLAC. It will be installed on net-desk1 - which is not visible from outside SLAC. The idea is to house a production system on jakarta2.slac.stanford.edu on which AJP13 will be used to redirect from an IIS server from outside.

PerfSONAR requires the following to operate:

  • eXist (XML db)
  • rrdtools
  • axis (soap)

TOMCAT

  • trying install on net-desk1: changing tomcat to run on port 80 (so security don't complain), run as root due to privalegded ports.
  • default users do not include the necessary admin and manager roles in tomcat-users.xml. adding them in allows the built in manager app.

EXIST

  • downloaded war file instead of full distro.
  • added exist-1.0rc.war to deloyed.
  • tomcat installs the war as exist-1.0rc; therefore the links don't work as it expects exist directory in webapps. therefore, added symlink.
  • added a rrdmaservice and lookupservice users to the exist db (as per the instructions).
  • dubious as this will work as i am using the tomcat war, rather than an external service running on port 8680 (as per instructuions)
  • sooo... also installed the jetty/html version as per the instructions (20060316), and repeated the user additions and the mkcol commands.

AXIS

  • perfsonar release recommends 1.2.1; only version 1.4 available on apache site.
  • need to link the folder axis/webapps/axis to the tomcat webapps directory.

perfSONAR

  • trying GUI install
  • needs to pick up the ENV settings for the fields (too much to change)
  • need to add AXIS_PATH/WEB-INF/lib/*.jar to CLASSPATH
  • also RRDTOOL_PATH/lib
  • and PERFSONAR_PATH/contrib/rrdjtool/build
  • selected to install everything; changed ports to 80 and changed exist port to 80
  • on configuring the exist stuff; a prompt comes up to connect to service. the URL is incomplete (after the hypen) - doesn't really matter as the readme says that i've done all this anyway (user creation).
  • also complains of cgmod a+x log.sh; file doesn't appear to exist in installation
  • got fed up with UI, so did console install:
[ytl@net-desk1:~/Work/perfSONAR/Installation/perfSONAR-1.0]$ ./install.pl 
Welcome to perfSONAR v1.0

Enter Information Common to the LS and MA:

Enter base path for the application:[/afs/slac.stanford.edu/g/scs/net/netmon/perfSONAR/Installation/perfSONAR-1.0]: /opt/perfSONAR/current/
Enter java path for the application:[/usr/local/java/current]: 
Enter the hostname:[net-desk1.slac.stanford.edu]: 
Enter the max file size of the log files (indicate KB or MB):[500KB]: 
Enter the number of backup logs to keep:[10]: 
eXist home directory:[/opt/exist/current]: 


Do you want to install the RRD MA?[y/n]: y
Enter Information Specific to the RRD MA:

Tomcat home directory:[/usr/local/tomcat]: /opt/tomcat/current
Axis home directory:[/opt/tomcat/current/webapps/axis]: 
Enter Tomcat port:[8080]: 80


Be sure to edit your CLASSPATH:
        CLASSPATH=$CLASSPATH:/opt/tomcat/current/webapps/axis/WEB-INF/lib/axis-ant.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/commons-discovery-0.2.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/jaxrpc.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/saaj.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/axis.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/commons-logging-1.0.4.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/log4j-1.2.8.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/wsdl4j-1.5.1.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/resolver.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/xercesImpl.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/perfSONAR-generic.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/activation.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/xmlrpc-1.2-patched.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/mail.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/commons-pool-1.1.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/xmlParserAPIs.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/perfSONAR-rrdma.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/xmlsec.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/xercesSamples.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/xml-apis.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/rrdjtool.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/xmldb.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/jdom.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/xalan.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/exist.jar
        export CLASSPATH

Please be sure axis is installed, and tomcat is running.

Enter rrdtool path:[/usr/local/rrdtool]: 


Be sure to edit your LD_LIBRARY_PATH:
        LD_LIBRARY_PATH=$LD_LIBRARY_PATH:/usr/local/rrdtool/lib:/opt/perfSONAR/current//contrib/rrdjtool/build
        export LD_LIBRARY_PATH

Enter general service name:[Measurement Archive Service]: 
Measurement Archive access point (URL):[http://net-desk1.slac.stanford.edu:80/axis/services/MeasurementArchiveService]: 
Measurement Archive service name:[Java MA]: 
Measurement Archive service type:[MA]: 
Measurement Archive service description:[Java RRD MA, perfSONAR project]: 


Do you want to register the RRD MA with a LookupService?[y/n]: y
Lookup Information to register with (URL):[http://net-desk1.slac.stanford.edu:80/axis/services/LookupService]: 
MA Storage Conf File:[/opt/perfSONAR/current//conf/rrd-database_TEST.xml]: 


Do you want the MA to use an eXist database?[y/n]: y
XML database collection:[xmldb:exist://localhost:8680/exist/xmlrpc/db/rrdmaconfig]: xmldb:exist://localhost:80/exist/xmlrpc/db/rrdmaconfig
XML database username:[rrdmaservice]: 
XML database password:[rrdmaservice]: 


Do you want the allow the MA to store data?[y/n]: y
RRD Storage Directory:[/opt/perfSONAR/current//data/rrd/test]: 


Do you want the installer to configure eXist for you?[y/n]: n

Don't forget to configure the eXist database for the RRD MA.

Processing file /opt/perfSONAR/current//wsdd/ma-service-undeploy.wsdd
<Admin>Done processing</Admin>
Processing file /opt/perfSONAR/current//wsdd/ma-service-deploy.wsdd
<Admin>Done processing</Admin>
mv: cannot stat `client/MA*': No such file or directory


Do you want to install the LS?[y/n]: y
Enter Information Specific to the LS:

Tomcat home directory:[/usr/local/tomcat]: /opt/tomcat/current
Axis home directory:[/opt/tomcat/current/webapps/axis]: 
Enter Tomcat port:[8080]: 80


Be sure to change your CLASSPATH:
        CLASSPATH=$CLASSPATH:/opt/tomcat/current/webapps/axis/WEB-INF/lib/axis-ant.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/commons-discovery-0.2.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/jaxrpc.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/saaj.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/axis.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/commons-logging-1.0.4.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/log4j-1.2.8.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/wsdl4j-1.5.1.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/resolver.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/xercesImpl.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/perfSONAR-generic.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/activation.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/xmlrpc-1.2-patched.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/mail.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/commons-pool-1.1.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/xmlParserAPIs.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/xmlsec.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/xercesSamples.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/xml-apis.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/xmldb.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/jdom.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/xalan.jar: \
/opt/tomcat/current/webapps/axis/WEB-INF/lib/perfSONAR-xmlls.jar:/opt/tomcat/current/webapps/axis/WEB-INF/lib/exist.jar
        export CLASSPATH

Please be sure tomcat, axis, and eXist are running.

Lookup Information of service -- access point (URL):[http://net-desk1.slac.stanford.edu:80/axis/services/LookupService]: 
Lookup Information of service -- service name:[Java LS]: 
Lookup Information of service -- service type:[LS]: 
Lookup Information of service -- service description:[Java LS, perfSONAR]: 
Lookup Service to register Lookup Information:[http://net-desk1.slac.stanford.edu:80/axis/services/LookupService]: 
Enter service name:[Lookup Service]: 

LS Storage -- XML database collection:[xmldb:exist://localhost:8680/exist/xmlrpc/db/ls]: xmldb:exist://localhost:80/exist/xmlrpc/db/ls
LS Storage -- XML database username:[lookupservice]: 
LS Storage -- XML database password:[sonar]: 


Do you want the installer to configure eXist for you?[y/n]: n
LS Cleanup -- cleanup interval (ms):[180000]: 
Register with LS interval (ms):[600000]: 
Processing file /opt/perfSONAR/current//wsdd/ls-service-undeploy.wsdd
<Admin>Done processing</Admin>
Processing file /opt/perfSONAR/current//wsdd/ls-service-deploy.wsdd
<Admin>Done processing</Admin>


Do you want to clean up the installation?[y/n]: y