Data: thrulay,iperf,pathchirp

Duration: 01/01/06 00:00 - 31/08/06 23:59

Thrulay (all variables)

 Route Plateau  PCA  Overlapping Events 
 SLAC-BINP 16   0
 SLAC-DESY  9  59  1
 SLAC-NSLABS  5  0  0
 SLAC-SDSC  8  0  0
 SLAC-UTORONTO  6  9  0

 

 

Correlation (tlaytcp)
  tlay-pca thrumin-pca thrumax-pca thrustd-pca rtt-min-pca rtt-avg-pca rtt-max-pca
binp 0.016432984 0.070069789 0.005563301 0.005153154 -0.166163842 -0.160117599 -0.084480398
desy 0.305577299 0.064415068 0.403433028 0.422706907 -0.227071507 -0.369057521 -0.307497092
nslabs 0.112552426 -0.260517674 0.339543711 0.48301406 0.102165527 -0.092604664 0.20161899
sdsc -0.293460283 -0.436878448 -0.080545761 0.670210333 0.039917806 0.094620517 0.275553869
utoronto -0.050563763 -0.20087636 0.619479063 0.926270869 -0.002288811 0.022830679 0.068496875

 

Thrulay (all variables except Max RTT)

 Route Plateau  PCA  Overlapping Events 
 SLAC-BINP 16   3  0
 SLAC-DESY  9  60  1
 SLAC-NSLABS  5  0  0
 SLAC-SDSC  8  0  0
 SLAC-UTORONTO  6  8  0

 

Correlation (tlaytcp)
  tlaytcp-pca thrumin-pca thrumax-pca thrustd-pca rtt-minp-pca rtt-avg-pca
binp 0.019580794 0.088901835 0.006633359 0.005821846 -0.176175414 -0.170247855
desy 0.342419569 0.11976718 0.478498512 0.497779956 -0.242991558 -0.35877671
nslabs 0.132343952 -0.252496309 0.356502935 0.491780016 0.07382788 -0.118401707
sdsc -0.312969911 -0.46078324 -0.098594683 0.688991435 0.042832191 0.081618934
utoronto -0.067201544 -0.225957678 0.208824225 0.223352128 0.004889931 0.025509686

Thrulay (througput variables)

 Route Plateau  PCA  Overlapping Events 
 SLAC-BINP 16   3  0
 SLAC-DESY  9  27  0
 SLAC-NASLABS   5  0  0
 SLAC-SDSC  8  0  0
 SLAC-UTORONTO  6  7  0

 

Correlation (tlaytcp)
  tlaytcp-pca thrumin-pca thrumax-pca thrustd-pca
binp 0.015842922 0.061763775 0.005966972 0.005750658
desy 0.378240782 0.155247626 0.493671351 0.499273767
nslabs 0.140624737 -0.24796054 0.364270575 0.498094835
sdsc -0.313853113 -0.46146319 -0.099237207 0.689379947
utoronto -0.067943634 -0.226900699 0.208679811 0.223339531

Thrulay (throughput variables except thrustd)

Route  Plateau  PCA  Overlapping Events 
 SLAC-BINP 16   1  0
 SLAC-DESY  9  767  6
 SLAC-NSLABS  5  0  0
 SLAC-SDSC  8  7  0
 SLAC-UTORONTO  6  63  2

 

Correlation (tlaytcp)
  tlaytcp-pca thrumin-pca thrumax-pca
binp 0.034173446 0.047448355 0.02322458
desy 0.224949527 0.011058987 0.669522229
nslabs 0.237050664 -0.214812821 0.462218512
sdsc -0.339324059 -0.501956225 -0.120055265
utoronto -0.349791164 -0.579165076 0.103919611

Pathchirp (all variables)

 Route Plateau  PCA  Overlapping Events 
 SLAC-BINP  4  0  0
 SLAC-BNL  4  0  0
 SLAC-TWAREN  0  20  0
 SLAC-CALTECH  2  0  0
 SLAC-UTORONTO  4  0  0
 SLAC-SDSC  0  0  0

 

 

Correlation
  pathchirp thru-min thru-max thru-std
binp 0.304552926 0.128924105 0.479074811 0.468488297
nl 0.158065689 0.040177254 0.25680967 0.330190135
twaren 0.319012894 0.255514685 0.37073895 0.393167609
toronto 0.224485492 0.171602772 0.285942436 0.372971396
sdsc 0.039077144 0.002372192 0.112468635 0.140539695
caltech 0.055842567 -0.02261612 0.156277482 0.286108454

 

Iperf (all variables)

 Route Plateau  PCA  Overlapping Events 
 SLAC-TORONTO  0  12  0
 SLAC-BNL  2  2  0
 SLAC-SDSC  1  3  1

 

 

Correlation
  iperf thrumin thruavg thrumax thrustd
toronto -0.427806824 -0.450819125 -0.411932061 -0.093317707 0.194256265
bnl 0.1858894 0.121985181 0.195214768 0.252765833 0.344864322
sdsc -0.298230102 -0.419956841 -0.214180978 -0.092055046 0.022387166