Dashboard > Calorimeter > Calorimeter
  Calorimeter Log In View a printable version of the current page.  
  Calorimeter
Added by Richard Dubois, last edited by Sanchez David on Oct 07, 2008  (view change)
Labels: 
(None)

Calorimeter Wiki Web Space

CAL Data Monitoring
  • I (Grove) have sent around a number of email messages about CAL Data Monitoring. I've tried to collect them in confluence at CAL Data Monitoring so they're more readily accessible in the future.
CAL Integration and Test
Date Name Summary
06/07/2004 (Instrument Analysis Workshop #1) A. Chekhtman Calibration of energy and position measurement in CAL
09/27/2004 (Instrument Analysis Workshop #2) M. Strickman How Does Calibration Flow Through the New Single CDE CalRecon and CalDigi?
09/27/2004 (Instrument Analysis Workshop #2) E. Grove CAL Calibration Data Sources During Assembly, Integration and Test
09/27/2004 (Instrument Analysis Workshop #2) A. Chekhtman CAL crosstalk issues and their Implications
09/27/2004 (Instrument Analysis Workshop #2) B. Lott Imaging crystals with TKR
09/27/2004 (Instrument Analysis Workshop #2) A. Makeev Light collection non-uniformity near the end of crystal
03/10/2005 (Instrument Analysis Workshop #3) Z. Fewtrell CAL Calibration Software
03/10/2005 (Instrument Analysis Workshop #3) D. Smith Recon at the Single Crystal Level
03/10/2005 (Instrument Analysis Workshop #3) B. Lott A first glance at the Tkr + Cal data
07/14/2005 (Instrument Analysis Workshop #4) D. Smith Stability of the CAL Calibrations
07/14/2005 (Instrument Analysis Workshop #4) A. Chekhtman Shaped Digital Readout Noise in CAL
07/14/2005 (Instrument Analysis Workshop #4) E. Nuss TKR tracks, CAL tracks and Crystal Maps
07/14/2005 (Instrument Analysis Workshop #4) Z. Fewtrell GLAST Calorimeter Crystal Position Measurement
07/15/2005 (Instrument Analysis Workshop #4) A. Chekhtman Summary of Current Understanding of CAL Retriggering
08/29/2005 (Instrument Analysis Workshop #5) F. Piron / E. Nuss Comprehensive review of CAL calibrations
02/24/2006 F. Piron / E. Nuss 24 Feb 06 Trending Report
02/27/2006 (Instrument Analysis Workshop #6) D. Smith Testing some CAL Specs
02/27/2006 (Instrument Analysis Workshop #6) F. Piron / E. Nuss Trending CAL performance and mapping crystals
02/27/2006 (Instrument Analysis Workshop #6) A. Chekhtman CAL Features and Idiosyncrasies
02/28/2006 (Instrument Analysis Workshop #6) J. Dai CAL LE trigger behavior for short and long track events
02/28/2006 (Instrument Analysis Workshop #6) E. do Couto e Silva Testing CAL LE and CAL HE triggers with muons and photons
02/28/2006 B. Giebels Range selections in B30
03/29/2006 B. Giebels LAT701 Run

Papers:

  • 207th AAS (Jan 2006): "Production, Calibration and Environmental testing of the GLAST/LAT CsI Calorimeter Flight Modules" (poster)
  • 1st GLAST Symposium (Feb 2007): "Performance of the Calorimeter of the GLAST Large Area Telescope" (poster, proceedings)
CAL in LAT Calibration Unit
Date Name Summary
11/14/2006 (Beam Test Workshop #4) P. Bruel Update on calorimeter studies
11/14/2006 (Beam Test Workshop #4) B. Lott Longitudinal profiles
11/14/2006 (Beam Test Workshop #4) A. Chekhtman Status of CAL calibration
11/14/2006 (Beam Test Workshop #4) B. Giebels Calibration with pions in SPS
11/15/2006 (Beam Test Workshop #4) J. Conrad Update on CAL FHE study
03/27/2007 (LAT collaboration meeting - GSFC) P. Bruel Beam tests and Energy measurement
03/27/2007 (LAT collaboration meeting - GSFC) A. Chekhtman Lessons learned from CAL calibrations
CAL GCR Calibration

06/10/2008

  • Zach: Final stages of producing initial flight calibrations including crosstalk corrections, etc.
  • Fred: Working on L&EO timeline for calibration. Redoing ion rate plots layer by layer
  • Berrie: Berrie, David, Zach, Sasha working on adapting David's LAC calibration model for NomSciOps data - about done. Next is FLE
  • Elliott: Yvonne needs to redo energy deposit study vs angle, energy with new MC (including LPM, etc)

06/17/2008

  • Berrie points out that being able to "join" AFEE temps and other calibration information would be desirable. He will look into this @ SLAC
  • Fred will submit sims to Zach's requirement to SLAC or Lyon pipeline
  • Fred asks who is responsible for validating filter performance during L&EO? Fred will send a note to Richard Hughes and Eric Grove about this

06/24/2008

  • Simulations for proton/interrange testing
  • Status
    • Zach
      • knee deep in proton interrange calibration code
        • currently building new app utilizing existing Muon & GCR calib code
        • Took some work, but now we have appropriate simulation code - intend to run existing GCR calib code on the new sim.
    • Sasha
    • Fred
    • Berrie
    • Philippe ftp://ftp-glast.slac.stanford.edu/glast.u33/bruel/mipcalibration/
    • Others

07/01/08

  • Summaries of analyses and plans for the next week

Calorimeter

  • Proton/Interrange vs GCR

07/15/08
Status and Plans:

07/22/08

Status and Plans:

  • Sasha
  • Zach
  • Fred
  • Berrie
  • Philippe
  • Others

07/29/08

Status and Plans:

08/05/08

  • Sasha - Update on position measurement
  • Zach
    • currently working on calibGenCAL GCR, adding asymmetry calibration to GCR code
    • still pushing TriggerAlg updates through GR CCB
    • intNonlin analisys, nomSciOps trigger threshold fitting on back burner
  • Fred
  • Luca, etc - CAL data monitoring discussion
  • Berrie
  • Philippe
  • Others

08/12/08

08.26.08

09.02.08

  • Sasha
  • Zach
  • Andrey
    • Status of new GCR simulations with MC truth info
  • Fred
  • Berrie,David
  • Others

09.30.08

  • Sasha
  • Andrey
  • Fred
  • Berrie,David
  • Others
  • NOTES
    • Berrie et. al. will do long term monitoring of threshold and LAC settings
    • Fred et. al. will do energy calibration monitoring using GCR
    • Suggestion that monitoring processes highlight new outliers
    • In GCR monitoring, we need to determine correct tradeoff between peak width (i.e. more stringent cuts) and statistics (less stringent cuts)
    • Sasha will be Zach's replacement as contact for threshold settings questions, deliveries, etc.

10.07.08

  • Sasha
    • Status of discrepancy between on-board and off-line energy
    • Status of implementation of on-orbit calibration in pipeline
    • Possible collaboration with Russian groups for further beam calibrations
  • Andrey
  • Fred
  • Berrie,David LACLAC_zoomFLE, FHE
  • Others

Papers:

  • D. Bederede et al., "Performance of the CsI(Tl) detector element of the GLAT calorimeter", NIM A 518, 15-18 (2004)
  • O. Ferreira et al., "Environmental tests of the GLAST validation module calorimeter", NIM A 530, 323-329 (2004)
  • B. Lott et al., for the GLAST collaboration, "Response of the GLAST LAT calorimeter to relativistic heavy ions", NIM A 560, 395 (2006) (pdf)
  • 1st GLAST Symposium (Feb 2007): "Heavy ion beam tests for the preparation of the LAT on-orbit calibration" (poster)
  • ICRC Conference (July 2007): "In-flight calibration of the GLAST Large Area Telescope calorimeter" (poster pdf, ppt, proceedings)
L&EO Meetings
Date Link
06.28.2008 EVO meeting
CAL Energy Reconstruction Methods
Date Name Summary
03/25/2005 B. Giebels Recon Algs extensions
10/17/2005 (note) P. Bruel Energy reconstruction at high energy with the LAT
02/09/2006 (note) P. d'Avezac A Maximum-Likelihood Energy Reconstruction Method
CAL Mip Finder
Date Name Summary
08/08/2005 (C&A meeting) F. Piron CAL Mip Finder (update)
06/29/2006 (Beam Test Workshop #3) F. Piron CAL Mip Finder and residual background rejection
11/15/2006 (Beam Test Workshop #4) F. Piron Validation of CAL Mip Finder algorithm with CERN / PS proton data
03/26/2007 (LAT collaboration meeting - GSFC) S. Guiriec Mip Finder: Performances and Proton Rejection
Useful Tips
Date Name Summary
03/06/2005 Z. Fewtrell Operation of Ideal gains
03/09/2005 D. Chamont How to try Fuzzy Clustering
04/11/2005 M. Strickman CalRecon and Digi Ideal Calibration Mode
11/05/2007 Z.Fewtrell CalTuple documentation
CalRecon Refactoring
Date Name Summary
07/19/2005 D. Chamont Pre-DC2 Refactoring Proposal
07/19/2005 T. Usher Cal Restructuring Action Items
05/04/2005 T. Usher CalRecon Data
03/09/2005 D. Chamont CalRecon Algorithms
04/13/2005 D. Chamont CalRecon Validation Script

Calorimeter Action Items in jira

Stanford Linear Accelerator Center (4 issues)
Key Summary Assignee Status
CAL-16 Cal Clustering and Saturation Issues Tracy Usher OpenOpen
CAL-15 project not work Mark Strickman OpenOpen
CAL-14 CPT - calf_adc_p02 crashes Mark Strickman OpenOpen
CAL-2 Remove CAL generic response parameters from xmlGeoDbs Zach Fewtrell OpenOpen

"Protons plus interrange" CAL energy scale calibration on orbit (Calorimeter)
01 Apr 08 GCR Meeting Notes (Calorimeter)
01 Feb 06 GCR Meeting Notes (Calorimeter)
04 Mar 08 GCR Meeting Notes (Calorimeter)
06 May 08 GCR Meeting Notes (Calorimeter)
08 Apr 08 GCR Meeting Notes (Calorimeter)
09March06 Sasha Notes on Alternative and Additional Inflight Calibrations (Calorimeter)
10 Jan 06 GCR Meeting Notes (Calorimeter)
10 July 06 GCR Meeting Notes (Calorimeter)
10 Oct 06 GCR Meeting Notes (Calorimeter)
12 Apr 06 GCR Calib Meeting Notes (Calorimeter)
12 Feb 08 GCR Meeting Notes (Calorimeter)
12 June 07 GCR Meeting Notes (Calorimeter)
14 Dec 05 GCR Meeting Notes (Calorimeter)
15 Apr 08 GCR Meeting Notes (Calorimeter)
15 Jan 08 GCR Meeting Notes (Calorimeter)
16 Nov 05 GCR Meeting Notes (Calorimeter)
17 May 06 GCR Meeting Notes (Calorimeter)
17 Oct 05 GCR Meeting Notes (Calorimeter)
18 Mar 08 GCR Meeting Notes (Calorimeter)
19 Feb 08 GCR Programmer Meeting Notes (Calorimeter)
2 Nov 05 GCR Meeting Notes (Calorimeter)
20 May 08 GCR Meeting Notes (Calorimeter)
21 June GCR Meeting Notes (Calorimeter)
21 Nov 06 GCR Meeting Notes (Calorimeter)
21 Sept 06 GCR Meeting Notes (Calorimeter)
22 Apr 08 GCR Meeting Notes (Calorimeter)
22 May 07 GCR Meeting Notes (Calorimeter)
23 Oct 07 GCR Meeting Notes (Calorimeter)
24 Feb 06 Trending Report (Calorimeter)
24 July 07 GCR Meeting Notes (Calorimeter)
24 Oct 06 GCR Meeting Notes (Calorimeter)
25 Jan 06 GCR Meeting Notes (Calorimeter)
25 Mar 08 GCR Meeting Notes (Calorimeter)
25 Sept 07 GCR Meeting Notes (Calorimeter)
26 Feb 08 GCR Meeting Notes (Calorimeter)
26 June 07 GCR Meeting Notes (Calorimeter)
28 Aug 07 GCR Meeting Notes (Calorimeter)
28 Mar 07 GCR F2F Meeting Notes (Calorimeter)
28 May 08 GCR Meeting Notes (Calorimeter)
29 Apr 08 GCR Meeting Notes (Calorimeter)
29 Jan 08 GCR Meeting Notes (Calorimeter)
29 Mar 06 GCR Meeting Notes (Calorimeter)
3 May 06 GCR Meeting Notes (Calorimeter)
31 Jan 07 GCR Meeting Notes (Calorimeter)
4 Dec 07 GCR Meeting Notes (Calorimeter)
6 Nov 07 GCR Meeting Notes (Calorimeter)
7 Dec 05 GCR meeting notes (Calorimeter)
7 Nov 06 GCR Meeting Notes (Calorimeter)
9 Oct 07 GCR Meeting Notes (Calorimeter)
CAL Data Monitoring (Calorimeter)
CAL LAC, FLE and FHE monitoring (Calorimeter)
CAL monitoring histograms - recommendations (Calorimeter)
CAL software update Jul 27, 2006 (Calorimeter)
CalTuple (Calorimeter)
Discarded events (Calorimeter)
Drift of calorimeter pedestals with time (Calorimeter)
Event Timestamps (Calorimeter)
Excess of events at low GemDeltaEventTime (Calorimeter)
Feb 06 IA Wrkshp-DC2 Kickoff GCR Calib Notes (Calorimeter)
GCR Calibration Flow (Calorimeter)
GLEAM Particle ID Notes (Calorimeter)
L&EO CAL Meeting 06.28.2008 (Calorimeter)
LAT701 Run (Calorimeter)
Leon_HI_TKR_digi (Calorimeter)
Notes on Applying Quenching in CalDigi (Calorimeter)
On-orbit calibration of the calorimeter thresholds (Calorimeter)
Pre-DC2 Refactoring Proposal (Calorimeter)
Range selections in B30 (Calorimeter)
test (Calorimeter)
Update on calorimeter energy scale calibration with protons (Calorimeter)

Powered by Atlassian Confluence, the Enterprise Wiki. (Version: 2.5.8 Build:#814 Oct 02, 2007) - Bug/feature request - Contact Administrators